Cedar Rapids Municipal Code § 29.56 702.4 Emergency Escape and Rescue Openings.
29.56 - 702.4 Emergency Escape and Rescue Openings.
Section 702.4 of the IPMC is hereby amended by adding the following as item 3 to said section:
3. Emergency escape and rescue openings shall have a net clear opening of not less than 5.7 square feet. The minimum net clear opening for grade-floor emergency escape and rescue openings shall be 5 square feet. The minimum net clear opening height shall be 24 inches. The minimum net clear opening width dimension shall be 20 inches. The net clear opening dimensions shall be the result of normal operation of the opening. Emergency escape and rescue openings shall have the bottom of the clear opening not greater than 44 inches above the floor. Emergency escape and rescue openings installed under decks, porches and cantilevers shall be fully openable and provide a path not less than 36 inches in height and 36 inches in width to a yard or court.
(033-24)