30.18 - MINIMUM REQUIREMENTS FOR THE INSTALLATION OF GAS-FIRED HEATING EQUIPMENT AND PIPING.
In addition to the requirements contained in the manuals and pamphlets listed in Appendix No. 1, which shall be classed as minimum standards of this code, the installation of gas heating equipment shall conform to the requirements set forth in the following subsections of this section and Section 30.07. (1) Scope. The provisions of this code, unless otherwise indicated herein, shall apply only to utilization pressure (not in excess of one-half (½) pound per square inch) gas pumping systems extending from the gas meter outlet connection to the inlet connections of appliances. They are intended to cover the design fabrication, installation and test of gas piping systems for fuel gases such as natural gas, liquefied petroleum gas, liquefied petroleum air, gas or mixtures thereof. They are not intended to cover systems or portions of systems supplying equipment engineered, designed and installed for specific manufacturing, production processing, large power generating application, melting and treating furnaces, production ovens and similar applications. Exception. Gas piping and control equipment requirements for systems using gas pressures in excess of one-half (½) pound per square inch. The use of gas in excess of one-half (½) pound per square inch may be used if the following requirements are met: 1. Generally, the valving arrangement shall conform to the American Standards Association (ASA-Z 21.33 - 1950). The Board will recognize as approved valving, arrangements and designs approved by any other nationally recognized approved agency. 2. A safety relief valve shall be placed downstream from a gas pressure regulator where gas is supplied at pressures in excess of one-half (½) pound per square inch. The discharge from the relief valve shall be piped to a safe location outside the building. (Valve setting not to exceed four (4) pounds.) 3. Provide a suitable pressure gauge in the gas line located downstream from the pressure regulator. 4. Where a gas supply pressure is higher than that at which the burners are designed to operate, a gas pressure regulator shall be provided to reduce pressure to satisfy design conditions. 5. Where the gas supply pressure is in excess of one-half (½) pound per square inch, the piping system shall be identified indicating the maximum line pressure. It is recommended that the legend "Gas ______________ P.S.I." be applied on gas piping near and downstream from pressure regulator at intervals of fifty (50) feet in every room or area which is less than fifty (50) feet. 6. Submit two (2) copies of drawings (schematic is acceptable) and specifications to the Building Inspection Division of the Department of Planning and Community and Economic Development for review and approval. (Am. by ORD-08-00109, 10-7-08) (2) Work on Gas Piping Containing Unmeasured Gas. Disconnecting inlet of gas meter, changing meter location or making connection to gas service pipe, shall be done only by gas company employees or others authorized by gas company to do such work. A pipefitter shall connect or disconnect the building piping from outlet meter connection when necessary. No person, unless in employ of gas company or having permission from gas company shall turn on or reconnect gas service in or on any premises where and when gas service is not at the time being rendered. It shall further be unlawful to turn on or supply gas on or at any premises unless at least one (1) gas appliance is connected to the gas piping system and all outlets are properly and securely connected to appliances or capped or plugged with screw joint fittings. (3) Authority to Disconnect. The Building Inspection Division of the Department of Planning and Community and Economic Development or the gas utility is hereby authorized to disconnect or have disconnected, any gas space heating equipment or gas piping, which shall be found not to conform to the requirements of this code, or which may be found defective and in such condition as to endanger life or property. Where such disconnection has been made, a notice shall be attached to such equipment or gas piping which shall state that the same has been disconnected, together with a reason therefore and such notice shall not be removed nor shall the equipment or gas be reconnected until authorized by the Building Inspection Division of the Department of Planning and Community and Economic Development to do so. (Am. by Ord. 8081, 7-29-83; ORD-08-00109, 10-7-08) (4) General Precautions. (a) Installation of Gas Piping. Installation of gas piping shall be performed with the gas turned off to eliminate hazards from leakage of gas. Connection of new piping system to existing system shall be done, if practical, with gas turned off. (b) Burner and Pilot Valves. Before turning off the gas at the meter, except in cases of emergency, all burner and pilot valves on the premises supplied with gas through the meter, shall be turned off and the meter test hand observed for a sufficient length of time to ascertain that there is no gas passing through the meter. When there is more than one meter on the premises, precaution shall be exercised to assure that the proper heater is turned off. (c) Checking for Gas Leakage. No matches, candles, flame or other source of ignition shall be employed to check for gas leakage from meters, piping or appliances. Check for gas leakage with a soap and water solution. (d) Artificial Illumination. Artificial illumination used in connection with a search for gas leakage shall be restricted to electric hand flashlights, fixed electric lights controlled only by explosion-proof safety switches or switches remote from the area of the leakage, or approved safety lamps. (e) Smoking Not Permitted. When connecting or disconnecting pipe which contains gas, smoking shall not be permitted. (f) Electrical Circuits Grounded to Gas Piping. Except for appliance controls requiring a ground electrical system including low voltage, circuits shall not be grounded to gas piping. (5) Piping to Meter Location. (a) Piping Extended to Meter Location. Gas building piping shall be extended to the meter location specified by the gas company. The meter location and gas piping connections shall be such that the meter connections are easily accessible in order that the meter may be read or changed. (b) Piping Marked. Piping from multiple meter installations, (four (4) or more meters) shall be plainly marked near outlet connection with a permanent tag by the installer so that the piping systems supplied through them can be readily identified. (c) Meters Supplied by Single Service Pipe. Unless otherwise approved in writing by gas company, all meters supplied by a single service pipe shall be at the same location. (d) Piping Systems not Interconnected. Unless otherwise approved, where two (2) or more meters are installed on the same premises but supply separate consumers, the piping systems shall not be interconnected on the outlet side of the meters. (e) Pipe Capacity Table 1. CAPACITY—CUBIC FEET PER HOUR WITH A 67 S.P. 970 BTU SP. GR. GAS AND PRESSURE DROP OF 0.3 INCH WATER COLUMN Length of Pipe in Ft | Nominal Diameter of Pipe in Inches ¾ | 1 | 1¼ | 1½ | 2 | 3 | 4 15 | 158 | 319 | 694 | 1130 | 2300 | 6000 | 12900 30 | 111 | 223 | 495 | 790 | 1640 | 4350 | 9000 45 | 92 | 184 | 403 | 650 | 1360 | 3600 | 7300 60 | 80 | 160 | 352 | 565 | 1200 | 3200 | 6300 75 | 71 | 144 | 317 | 500 | 1040 | 2775 | 5550 90 | 65 | 131 | 287 | 455 | 925 | 2500 | 5100 105 | 60 | 123 | 264 | 415 | 850 | 2250 | 4700 120 | 111 | 250 | 390 | 795 | 2125 | 4450 150 | 101 | 224 | 350 | 720 | 1925 | 4050 180 | 93 | 208 | 325 | 670 | 1800 | 3700 210 | 190 | 295 | 610 | 1650 | 3400 240 | 176 | 280 | 570 | 1550 | 3200 270 | 165 | 265 | 535 | 1450 | 3000 300 | 158 | 250 | 500 | 1375 | 2750 450 | 130 | 210 | 415 | 1150 | 2300 600 | 110 | 180 | 360 | 950 | 1975 (6) Size of Piping to Gas Appliances. (a) Piping shall be of such size and so installed as to provide a supply of gas sufficient to meet the maximum demand without undue loss of pressure between the meter and the appliance or appliances. The minimum gas pipe shall be not less than three-fourths (¾) inch. This does not apply to water heaters, space heaters, and unit heaters with inputs of less than fifty thousand (50,000) input. The size of the gas pipe to be used depends upon the following factors: 1. Allowable loss in pressure to be provided for. 2. Maximum gas consumption to be provided for. 3. Length of pipe and number of fittings. 4. Specific gravity of the gas. 5. Diversity factor. (b) Pressure Loss. The pressure loss in any gas piping system from the gas meter to any appliance for the maximum demand shall not exceed 0.3 inch water column. The minimum size of piping required to comply with 0.3 inch pressure loss limitation shall be determined by procedure given in Subsection (c) below or by standard engineering methods including use of gas flow computers. (c) Size of Piping. To determine the size of any section of gas pipe in a system, proceed as follows: 1. Measure the length of pipe from the gas meter to the most remote outlet in the building on that piping system. Where separate or individual fuel lines are extended from meter to one or more appliances, such as individual gas line to heating plant, each separate fuel line from meter shall be considered as separate piping system. 2. In Table No. 1, select the horizontal line showing that distance, or the next longer distance if the table does not give the exact length. 3. Use this horizontal line so selected to locate all gas demand figures for this particular system of gas piping. 4. Starting at the most remote outlet, find in the horizontal line just selected, the gas demand for that outlet. If the exact figure of demand is not shown, choose the next larger figure in the same horizontal line. 5. Above this demand figure in the first line at the top of Table No. 1 will be found the correct size of pipe required to serve such an outlet. 6. Proceed in a similar manner for each outlet and each section of pipe. For each section of pipe, determine the total gas demand supplied by that section and use the length indicated by Section 30.18(5)(e) above, which length is at all times taken as total distance from meter to most remote outlet. 7. The hourly volume of gas required at each outlet shall be taken as not less than the maximum hourly rating specified by the manufacturer of the appliance or appliances to be connected to each such outlet. Where the manufacturer's rating of an appliance is given in British Thermal Units (BTU) per hour, this rating shall be divided by nine hundred seventy (970) to obtain the corresponding gas demand in cubic feet per hour for natural gas. Where BTU rating of gas appliances to be installed has not been definitely specified, estimate of approximate requirements may be based on current typical appliances. (d) Extensions to Existing Piping. Extensions to existing piping shall conform to Section 30.18(6)(a). Existing piping, if extended, shall be converted to the proper size of pipe where necessary. In no case shall extensions be made to existing pipe which is smaller than permitted by Section 30.18(6)(a). (7) Materials for Pipe and Fittings. All piping systems shall be installed according to NFPA 54 - National Fuel Gas Code (1987). (R. & Re-Cr. by Ord. 10,255, Adopted 5-7-91) (8) Reserved for Future Use. (R. by Ord. 10,255, Adopted 5-7-91) (9) Reserved for Future Use. (R. by Ord. 10,255, Adopted 5-7-91) (10) Reserved for Future Use. (R. by Ord. 10,255, Adopted 5-7-91) (11) Reserved for Future Use. (R. by Ord. 10,255, Adopted 5-7-91) (12) Reserved for Future Use. (R. by Ord. 10,255, Adopted 5-7-91) (13) Reserved for Future Use. (R. by Ord. 10,255, Adopted 5-7-91)
(Am. by Ord. 8081, 7-29-83)
Ask a question about Madison law
Corpus searches the Madison sections it holds and shows the ones that match, with their citations. Free, no sign-in.