For AI agents: read the machine-readable documentation index at /llms.txt or the single-file full reference at /llms-full.txt.

§ 11.79.150 — Ladders, recessed steps, and stairs

Revised Code of the City of Saint Louis, 2020, Annotated (Supp. No. 11: codified through Ordinance No. 72042, enacted October 30, 2025) · St. Louis Revised Code § 11.79.150

Corpus is an independent public-information project, not the official City of St. Louis website. Stable reference: corpuslaw.us/code/26bb9b5c-360a-42b4-99bd-84cc753744f3

11.79.150 - Ladders, recessed steps, and stairs.

A. Location. Steps or ladders shall be provided to serve the shallow and deep portions of the pool, and if the pool is over thirty (30) feet wide, such steps or ladders shall be installed on each side. Stairs, ladders, and recessed steps should be located so as not to interfere with racing lanes or with diving. B. Stairs. Stairs leading into pools shall have a minimum tread of twelve (12) inches and a maximum rise not to exceed ten (10) inches. There shall be no abrupt drop-off or submerged projections into the pool, unless guarded by handrails. C. Ladders. Pool ladders shall be corrosive resistant and shall be equipped with non-slip treads. All ladders shall be designed to provide a handhold and shall be rigidly installed. There shall be a clearance of not more than six (6) inches nor less than three (3) inches between the ladder and the pool wall. D. Step-holes. If step-holes are inserted into the walls or if step-holes are provided, they shall be of such design that they may readily be cleaned and shall be arranged to drain into the pool to prevent the accumulation of dirt. Step-holes shall have a minimum tread of five (5) inches and a minimum width of fourteen (14) inches. E. Handrails. Where stairs, step-holes, or ladders are provided within the pool, there shall be a handrail at the top of both sides thereof extending over the coping or edge of the deck. F. Steps and Guard Rails for Diving Boards. Supports, platforms, and steps for diving boards shall be of substantial construction and of sufficient strength to safely carry the maximum anticipated loads. Steps shall be of corrosive-resistant material, easily cleanable, and of non-slip design. Handrails shall be provided at all steps and ladders leading to the diving boards which are one (1) meter above the water. Platforms and diving boards which are one (1) meter or more high, shall be protected with guard railings.

(1994 C., § 11.79.150; Ord. No. 65567, § 15, 2002.)

Ask a question about St. Louis law

Corpus searches the St. Louis sections it holds and shows the ones that match, with their citations. Free, no sign-in.