SEC. 11-729. - LIGHT AND VENTILATION COURT.
A window may open into an existing court for light and ventilation, provided, the court is has adequate access at the bottom of the court for cleaning purposes. Every court more than two stories in height shall be provided with a horizontal air intake at the bottom of the court from the court to the exterior of the building, unless the court opens to a yard or public way. The horizontal air intake shall not be less than 10 square feet in cross-sectional area and shall lead to the exterior of the building. The construction of the horizontal air intake shall be as required for the court walls of the building, but in no case shall be less than one-hour fire-resistive construction. A mechanical ventilation system complying with the Mechanical Code may vent the court in lieu of the horizontal air intake. EXCEPTION: when approved by the building official, an existing court may be deemed adequate for the purpose of providing light and ventilation based upon the area and height of the court.
(Added Ord. 2007-102, § 1, eff. 1-20-08).