Sec. 49-624. - Trench and linear drains.
Trench drains shall have a cover designed to withstand the expected traffic loads. They shall also comply with the following provisions:
(a) Length.
(1) Size and length shall be as require in Table 49-624 below:
Table 49-624
Wastes (size in inches) | Maximum Length (ft)
2 | 2
3 | 10
4 or greater | No limits
(2) When trench drains are used in a garage, see sections 49-614, 49-1140 and 49-1141.
(b) Molded trench drains.
(1) Shall conform to ANSI A1 12.21.1M.
(2) Shall be at least four inches wide at the throat of the trench, and at least four inches deep at the shallowest point.
(3) The bottom of the trench drain shall slope at least 0.6 percent to the waste connection.
(4) Section seams shall be bolted, flanged connections with a gasket or a manufacturer's approved sealant.
(5) Shall be encased in a minimum thickness of four inches of concrete.
(c) Stainless steel trench drains.
(1) Shall conform to ANSI A1 12.21.1M.
(2) Shall be at least four inches wide at the throat of the trench, at least four inches deep at the shallowest point. The bottom of the trench drain shall slope at least 0.6 percent to the waste connection. Section seams shall be bolted, flanged connections with a gasket or a manufacturer's approved sealant.
(3) When used within restaurants, food processing, hospitals, slaughter houses, dairies, and breweries, shall be #14 gauge, Type 304 stainless steel construction. Section seams shall be bolted, flanged and then welded inside, and ground to a smooth finish.
(4) When used in corrosive conditions, chemical industries, pharmaceutical plants, and acid waste systems, shall be all #14 gauge, Type 304 stainless steel construction. Section seams shall be welded, and ground to a smooth finish.
(5) Shall be encased in a minimum thickness of four inches of concrete.
(d) Poured-in-Place trench drains.
(1) Shall be at least four inches wide at the throat of the trench, and at least four inches deep at the shallowest point. The bottom of the trench drain shall slope at least one-eighth inch per foot to the waste connection.
(2) The walls and floor of the drain shall be a minimum thickness of four inches of concrete.
(3) There shall be a three-fourths-inch wide metal frame poured in place to support the cover.
(e) Linear drains. Shall be approved by the plumbing board as to the design and material used according to the following minimum requirements:
(1) Shall be constructed of stainless steel #14 gauge, Type 304 SS.
(2) Shall have a minimum two-inch waste outlet.
(3) If used above the lowest level or for shower drains, the product shall provide a means to connect a shower pan liner.
(4) The plumbing board shall keep a list of all approved linear drains on file with the secretary.