15.08.021 - Amendments made in the International Building Code.
A. Section 101.1, Title, is amended to read as follows: 101.1: Title. These regulations shall be known as the Building Code of the City of Cottonwood, hereinafter referred to as "this code." B. Section 105.1, Required permits, is amended to add Section 105.1.3, Tenant occupancy permits, to read as follows: 105.1.3: Tenant occupancy permit. Prior to opening a business, except U occupancies, a Tenant Occupancy Permit shall first be obtained. Tenant Occupancy Permits that result in a change of use shall conform to the respective code requirements and shall obtain the required permits as specified in Section 105.1. Where the change of use alters the existing occupant load, a new certificate of occupancy shall be issued. At the discretion of the building official, an evaluation by a licensed design professional may be required to ensure compliance with the adopted codes. C. Section 105.2, Work exempt from permit, is amended to amend item 1 under the "Building" category to read as follows: 1. One-story detached, non-habitable accessory structures used as tool and storage sheds, playhouses, and similar uses, provided the floor area is not greater than 200 square feet and the building height does not exceed twelve feet at the highest point of the roof of wall. D. Section 107.1, General, is amended to read as follows: 107.1: General. Submittal documents consisting of construction documents, statement of special inspections, geotechnical report and other data shall be submitted in two or more sets, or in a digital format where allowed by the building official, with each permit application. The construction documents shall be prepared by a registered design professional, as required by A.R.S. § 32-144 and the State of Arizona Board of Technical Registration. Where special conditions exist, the building official is authorized to require additional construction documents to be prepared by a registered design professional. Exception: The building official is authorized to waive the submission of construction documents and other data not required to be prepared by a registered design professional if it is found that the nature of the work applied for is such that review of construction documents is not necessary to obtain compliance with this code. E. Section 107.2.1, Information on construction documents, is amended to read as follows: 107.2.1: Information on construction documents. Construction documents shall be dimensioned and drawn on suitable material. Electronic media documents are permitted to be submitted where approved by the building official. Construction documents shall be of sufficient clarity to indicate the location, nature and extent of the work proposed and show in detail that it will conform to the provisions of this code and relevant laws, ordinances, rules and regulations, as determined by the building official. Submitted documents shall identify the scope of work (project summary) and reference the City's adopted design codes and criteria. F. Section 110.5, Inspection requests, is amended to add Section 110.5.1, Elevated work and rooftop inspections, to read as follows: 110.5.1: Elevated work and rooftop inspections. For all elevated work and rooftop inspections, adequate fall protection measures shall be in place to ensure the safety of inspectors prior to requesting an inspection. The permit holder or contractor shall provide and maintain approved fall protection systems, including but not limited to: 1. Guardrails - Installed in accordance with OSHA and building code requirements. 2. Safety Nets - Positioned and maintained to prevent falls where guardrails are not feasible. 3. Personal Fall Arrest Systems Properly anchored and utilized when required. 4. Other alternate safety methods approved by the Building Official. The permit holder or contractor is responsible for ensuring compliance with all applicable safety regulations before an inspection is conducted. If fall protection cannot be provided, the permit holder or property owner must sign a liability indemnification waiver, indemnifying and holding the City and its inspectors harmless from any injuries or claims arising from the inspection. The Building Official reserves the right to deny or postpone inspections if adequate safety measures are not in place. G. Section 111.3, Temporary occupancy, is amended to read as follows: 111.3: Temporary occupancy. The building official is authorized to issue a temporary certificate of occupancy before the completion of the entire work covered by the permit, provided that such portion or portions shall be occupied safely. The building official shall set a time period during which the temporary certificate of occupancy is valid. The issuance of Temporary Certificates of Occupancy is not customary and shall be reviewed by the Community Development Director after the submittal of a written request identifying the hardship(s) not caused directly or indirectly by the applicant, property owner, design professionals, or contractors. Upon approval of the Community Development Director to allow issuance of a Temporary Certificate of Occupancy, the owner shall submit to the Building Official for review and approval a letter requesting temporary occupancy for a period to be approved by the Building Official and include with the request: 1. An itemization of all work authorized and required by the building and grading permits that must be completed to permanently occupy the building. 2. An irrevocable bond or other financial deposit acceptable to the Building Official and payable to the City of Cottonwood in the event construction is not completed before the expiration of the Temporary Certificate of Occupancy. The amount of the bond or deposit shall equal 100 percent of the construction cost to complete the work required by the permits. 3. For the purpose of this section, construction cost shall include all labor, materials, equipment, sales tax, permit fees, and contractors' profit and overhead plus a twenty percent (20%) contingency amount for unforeseen construction expenses and City administration in the event the City undertakes the completion of the project. The Building Official may require written proposals or estimates from contractors to substantiate the amount of the bond or deposit. 4. The payment of a non-refundable fee for the Temporary Certificate of Occupancy shall be $200.00 for single-family dwellings and $500.00 for commercial projects. 5. A written agreement that the bond or deposit is forfeited by the owner to the City in the event all required work is not completed before the expiration of the Temporary Certificate of Occupancy and authorization for the City to undertake and complete construction with the forfeited funds. If the City undertakes the completion of the project with the forfeited funds, any unexpended amount shall be returned to the' owner or bonding agent as applicable. If costs to complete the project exceed the amount of the bond or deposit, the City may file a lien against the subject property and take appropriate action as necessary to recover all the additional expenses incurred completing the construction. The Building Official may extend the time period of an original Temporary Certificate of Occupancy or issue one or more additional temporary certificates if conditions beyond the control of the owner prevent project completion by the expiration of the original Temporary Certificate. Extensions and additional temporary certificates shall be requested by the owner before the expiration of the original certificate and approved by the Building Official in the same manner as the original certificate. The owner shall provide a bond or deposit and pay a new fee for each extension or additional certificate. Exception: Public schools are not required to provide a bond or deposit for the completion of work or pay temporary certificate fees. H. Section 115.2, Issuance, is amended to read as follows: 115.2: Issuance. The stop work order shall be in writing and shall be given to the owner of the property, the owner's authorized agent or the person performing the work. Posting of the Stop Work order on the structure or property in question shall be deemed proper notification to the owner or owner's authorized agent. Upon issuance of a stop work order, the cited work shall immediately cease. The stop work order shall state the reason for the order and the conditions under which the cited work is authorized to resume. I. Section 115.4, Failure to comply, is amended to read as follows: 115.4: Failure to comply. Any person who removes a posted stop work order or continues any work after having been served with a stop work order, except such work as that person is directed to perform to remove a violation or unsafe condition, shall be subject to fines established by the authority having jurisdiction. J. Section 116.3, Notice, is amended to read as follows: 116.3: Notice. If an unsafe condition is found, the building official shall serve on the owner of the structure, or the owner's authorized agent, a written notice that describes the condition deemed unsafe and specifies the required repairs or improvements to be made to abate the unsafe condition, or that requires the unsafe structure to be demolished within a stipulated time. Such notice shall require the person thus notified to declare immediately to the building official acceptance or rejection of the terms of the order. Structures deemed an immediate hazard will be posted with an "Unsafe to Occupy" order. Removal of such posted orders shall be subject to fines established by the authority having jurisdiction. K. Section 202.2, Definitions, is amended to add the following definition: ELEVATED WORK. A walking/working surface (horizontal and vertical surface) with an unprotected side or edge which is six feet (1.8 m) or more above a lower level. L. Section 1101.1, Scope, is amended to read as follows: 1101.1: Scope. The provisions of this chapter and of Arizona Revised Statutes Sections 41-1492 through 41-1492.12 shall control the design and construction of facilities for accessibility for individuals with disabilities. M. Section 1102.1, Design, is amended to read as follows: 1102.1: Design. Buildings and facilities shall be designed and constructed to the more restrictive of the following adopted regulations and technical codes: 1. The 2010 Standards for State and local governments, which consist of Title II regulations of 28 CFR 35.15 and 2004 ADAAG of 36 CFR part 1191, appendices B and D; 2. The 2010 Standards for public accommodations and commercial facilities, which consist of the Title III regulations of 28 CFR 36 subpart D and the 2004 ADAAG of 36 CFR part 1191, Appendices B and D; 3. This code; 4. ICCA117.1-2017. N. Section 1705, Required special inspections and tests, is amended to add Section 1705.21, Electrical special inspections, Section 1705.22, Mechanical special inspections, and Section 1705.23, Plumbing special inspections, to read as follows: 1705.21: Electrical special inspections. The types of equipment or installations noted below shall be tested or inspected by a special inspector or licensed design professional. 1. Ground-fault protection performance tests for equipment provided with ground-fault protection as required in Section 230.95(C) of the National Electrical Code. 2. Switchboards, panelboards, motor control centers, and other equipment rated at 1,000 amperes or more, or over 600 volts. 3. Transformers rated 100 KVA or more, single phase; or 300 kVA or more, three phase. 4. Conductors that supply equipment rated at 1,000 amperes or more, or over 600 volts. 5. Emergency and legally required standby power systems, including switchboards, panelboards, distribution boards, transfer equipment, power source, conductors, fire pumps, and exhaust and ventilation fans. 6. Selective Coordination - This includes verification of the installation in accordance with the required selective coordination study. 7. Installation or alteration of that portion of health care facility electrical systems that falls within the scope of Article 517 of the National Electrical Code, including such systems installed in facilities where outpatient surgical procedures are performed 8. Installation or alteration of electrical systems within locations classified as hazardous by provisions of the National Electrical Code, except for gasoline dispensing installations and systems located within storage garages, repair garages or lubritoriums. 9. Special cases - Work which, in the opinion of the building official, involves unusual hazards or conditions. Exception: The building official may waive the requirement for special inspection if the construction is of a minor nature. 1705.22: Mechanical special inspections. The types of equipment or installations noted below shall be tested or inspected by a special inspector or licensed design professional: 1. Duct smoke detectors for air distribution systems as required by International Mechanical Code section 606.5. 2. Fire, fire/smoke, radiation, and smoke damper operation for dampers required by International Mechanical Code section 607.2. 3. Installation of grease duct enclosure alternative systems allowed under the exceptions to the International Mechanical Code section 506.3.11. 4. Special cases - Work which, in the opinion of the building official, involves unusual hazards or conditions. 5. Test and Balance report for air balance of ventilation systems installed in ambulatory care and 1-2 occupancies designed and installed in accordance with ASHRAE 170 as required by International Mechanical Code section 407.1. Exception: The building official may waive the requirement for special inspection if the construction is of a minor nature. 1705.23: Plumbing special inspections. The types of equipment or installations noted below shall be tested or inspected by a special inspector. 1. Medical Gas and Vacuum Systems as required by International Plumbing Code section 1202. 2. Special cases - Work which, in the opinion of the building official, involves unusual hazards or conditions. Exception: The building official may waive the requirement for special inspection if the construction is of a minor nature. O. Section 1807.1.6, Prescriptive design of concrete and masonry foundation walls, is amended to read as follows: 1807.1.6: Prescriptive design of concrete and masonry foundation walls. Concrete and masonry foundation walls that are laterally supported at the top and bottom shall be permitted to be designed and constructed in accordance with this section, provided that the minimum vertical reinforcement for any concrete or masonry foundation wall shall be a #4 spaced not more than 48 inches on center. Un-reinforced concrete (PC) is not permitted. P. Table 2902.1, Minimum number of required plumbing fixtures, is amended to add footnote "h" to read as follows: h. Water coolers or bottled water dispensers may be substituted for drinking fountains in B, M, and S occupancies with twenty-five (25) or fewer occupants. Such water shall be free of charge to the public. Q. Section 2902.2, Separate facilities, is amended to read as follows: 2902.2: Separate facilities. Where plumbing fixtures are required, separate facilities shall be provided for each sex. Exceptions: 1. Separate facilities shall not be required in structures or tenant spaces with a total occupant load, including employees and customers, of twenty-five (25) or less. R. Section 3306.9, Adjacent to excavations, is amended to read as follows: 3306.9: Adjacent to excavations. Every excavation on a site located 5 feet (1524 mm) or less from the lot line shall be enclosed with a barrier not less than 6 feet (1829 mm) in height. Where located more than 5 feet (1524 mm) from the lot line, a barrier shall be erected where required by the building official. Barriers shall be of adequate strength to resist wind pressure as specified in Chapter 16.
(Ord. No. 640, § 3, 6-19-2018; Ord. No. 662, § 3, 5-21-2019; Ord. No. 761, § 2, 5-20-2025)
Ask a question about Cottonwood law
Corpus searches the Cottonwood sections it holds and shows the ones that match, with their citations. Free, no sign-in.