§ 23.04.210 — Regulations for large connections, six-inch and larger

Revised Code of the City of Saint Louis, 2020, Annotated (Supp. No. 11: codified through Ordinance No. 72042, enacted October 30, 2025) · St. Louis Revised Code § 23.04.210

Corpus is an independent public-information project, not the official City of St. Louis website. Stable reference: corpuslaw.us/code/469a25ad-57f3-4997-a576-6b0ebd8ed081

23.04.210 - Regulations for large connections, six-inch and larger.

A. All large connections, for domestic use, fire protection use, or combined fire protection and domestic use, shall have, in addition to the stop valve in the street, another valve, for use of the occupant, where the pipe first enters the building. Parties desiring attachments for supplying water to large connections shall file an application with the Water Commissioner, stating such information pertaining to the subject as he may require. B. For these attachments, only the installation of taps, tapping valves and water meters will be made by the Water Commissioner. Such attachments will be made by the Water Commissioner at the cost of the parties desiring the attachment when, in the opinion of the Water Commissioner, the attachment or the use thereof will not interfere with or endanger the water supply to buildings in the immediate vicinity. The Water Commissioner may require the installation of air chambers of sufficient capacity to prevent water hammer from being transmitted to the distribution system. The Water Commissioner may also require air gaps or backflow preventers on services that may, in his opinion, pose a hazard to the water system. Connection for furnishing water for fire purposes shall not be used for any other purpose unless a proper type of water meter is placed thereon at the cost of the parties desiring the water. C. The parties desiring attachments shall do all excavation, backfilling, and pavement replacement required. The Water Commissioner will furnish a sketch of the excavation required for tapping the water main and will proceed with tapping only when excavation conforms to this sketch and is safe. The parties desiring attachments shall install all piping, valve boxes, meter boxes, et cetera required to conform to the Water Division's standard drawings before service is granted. The parties desiring attachments shall install materials conforming to the standards on file in the Water Commissioner's Office and shall provide proof of compliance to the Water Commissioner before service is to be granted.

(1948 C., Ch. 55, § 55; 1960 C., § 547.220(part); 1994 C., § 23.04.210; Ord. No. 57997, § 1(part), 1980.)

Ask a question about St. Louis law

Corpus searches the St. Louis sections it holds and shows the ones that match, with their citations. Free, no sign-in.