Sand/oil gravity separation interceptor.
Riverside Municipal Code § 14.12.255
in effect14.12.255 - Sand/oil gravity separation interceptor.
No user that operates or maintains a facility for the servicing or repair of roadway machinery, industrial transportation equipment, motor vehicles, public or private transportation vehicles, and any other facility as required by the Director, shall discharge wastewater to the POTW without a gravity separation interceptor ("interceptor") that complies with all of the requirements of this chapter pertaining to sand/oil interceptors. Domestic wastewater shall not be allowed to pass through the interceptor. The Director shall determine the interceptor's operational fluid capacity. The interceptor shall have a minimum operational fluid capacity of not less than 100 gallons, and shall be designed to retain any material that will float or any material that will settle and shall meet all the requirements of this chapter. The interceptor shall be equipped with a sample box.
(Ord. 7362 §6, 2017; Ord. 7032 §2, 2009; Ord. 6377 §2 (part), 2002; Ord. 6232 §2 (part), 1995)