SEC. 11-723. - EXIT STAIRWAY.

All exit stairways shall be enclosed and shall comply with all the requirements of C.B.C. Section 1005.3.3. Existing exit stairway enclosures may be allowed to pass through the first-floor elevator lobby, provided an approved fire-rated smoke-sealed door is placed in front of the elevator door on the first floor or there is another exit stairway enclosure leading directly to the public way. A photoluminescent stairwell marking system shall be provided as a condition of the adaptive re-use building permit for buildings with more than 2 stories. Installation shall be in accordance with Fire Department installation guidelines.

(Added Ord. 2007-102, § 1, eff. 1-20-08).