§ 30.13 — DESIGN OF A FORCED WARM AIR SYSTEM
Madison General Ordinances (Rev. 28, Update 3: codified through ORD-26-00040, published August 3, 2026) · Madison General Ordinances § 30.13
Corpus is an independent public-information project, not the official City of Madison website. Stable reference: corpuslaw.us/code/6134c85b-41f9-498c-8421-e9112819d2e7
30.13 - DESIGN OF A FORCED WARM AIR SYSTEM.
(1) For one (1) and two (2) family structures with a BTU requirement NOT in excess of one hundred twenty thousand (120,000) BTU per hour, the furnace shall be selected and installed according to Manual 7 of the N.W.A.H.A.C. Association as listed in Appendix No. 1. (2) For one (1) and two (2) family structures having a BTU requirement in excess of one hundred twenty (120,000) BTU per hour, the furnace shall be selected and installed according to Manual 9 of the N.W.A.H.A.C. Association as listed in Appendix No. 1. (3) In the design of warm air perimeter heating systems, the furnace shall be selected and installed according to Manual 4 of the N.W.A.H.A.C. Association as listed in Appendix No. 1. (4) In the design of a small pipe, warm air, perimeter system, the furnace shall be selected and installed according to Manual 10 of the N.W.A.H.A.C. Association as listed in Appendix No. 1. (5) Design of a Warm Air Ceiling Panel System. (a) Selection and Installation of Furnace. The furnace shall be selected and installed according to Manual 7-A of the N.W.A.H.A.C. Association as listed in Appendix No. 1. (b) Use. 1. Temperature Limit. Heating panels shall be used only with automatically fired, gas or oil burning, forced warm air systems equipped with temperature limit controls that cannot be set above two hundred (200) degrees Fahrenheit. 2. Combination Systems. Heating panels may be used with forced warm air systems equipped with heat exchangers utilizing steam which cannot exceed fifteen (15) pounds gauge pressure or hot water which cannot exceed a temperature of two hundred (200) degrees Fahrenheit. (c) Construction. 1. Panel Construction. Where warm air supply is from a warm air furnace, heating panels shall be enclosed on all sides with material which is wholly incombustible or which possesses a flame spread classification of not over twenty (20), as determined in accordance with the Method for Fire Hazard Classification of Building Materials, NFPA No. 255, ASTM E84-50T, Underwriters' Laboratories, Inc. Standard. This enclosing material shall be securely attached to the building structure; joints and seams shall be substantially air tight. Braces and hangers inside the chamber shall be incombustible. 2. Combination System Panel. Where warm air supply is from a steam or hot water heat exchanger, heating panels shall either comply with Section 30.13(5)(c) or shall be enclosed on all sides with material not more flammable than one (1) inch wood boards. This enclosing material shall be securely attached to the building structure; joints and seams shall be substantially air tight. No single vertical heating panel shall serve more than one (1) story.
Ask a question about Madison law
Corpus searches the Madison sections it holds and shows the ones that match, with their citations. Free, no sign-in.