Sec. 44-184. - Air gap separation.

Air gap separations provide maximum protection from backflow hazards and may be utilized in water systems situated on premises where a substance is present which would be hazardous to health if introduced into the potable water system. (1) An air gap separation shall be at least twice the diameter of the supply pipeline measured vertically above the top rim of the receiving vessel, and in no case less than one inch. If splashing is a problem, tubular screens may be attached or the supply line may be cut at a 45-degree angle, and the air gap distance shall in such case be measured from the bottom of the angle. Hoses shall not be used. (2) Air gap separations shall not be altered in any way without prior written approval from the director, and must be accessible for inspection at all reasonable times. (3) Side walls, ribs, or similar obstructions shall be spaced from the inside edge of the spout opening to a distance greater than three times the diameter of the effective opening for a single, or to a distance greater than four times the effective opening for two intersecting walls. (4) In systems where there are three or more side walls, ribs, or similar obstructions extending from the water surface to or above the horizontal plane of the spout opening in a manner other than specified in subsection 44-183(c), the air gap shall be measured from the top of the wall. (5) The effective opening shall be the minimum cross sectional area at the seat of the control valve or the supply pipe or tubing which feeds the assembly or outlet. If two or more lines supply one outlet, the effective opening shall be the sum of the cross sectional areas of the individual supply lines or the area of the single outlet, whichever is smaller.

(Code 1995, § 10.712; Ord. No. O-2015-2423, § I, 5-14-2015)

Ask a question about Round Rock law

Corpus searches the Round Rock sections it holds and shows the ones that match, with their citations. Free, no sign-in.