For AI agents: read the machine-readable documentation index at /llms.txt or the single-file full reference at /llms-full.txt.

§ 9-14-33 — Mechanical and Utility Equipment

Boulder Revised Code 1981 (Supplement167; ordinances effective through July30,2026; five publisher-pending ordinances held); partial · Boulder Revised Code 1981 § 9-14-33

Corpus is an independent public-information project, not the official City of Boulder website. Stable reference: corpuslaw.us/code/792d347b-1ae4-4c29-af56-c340bda36638

9-14-33. - Mechanical and Utility Equipment.

(a) Intent. Mechanical equipment and utility equipment can have a negative visual impact and detract from the quality of the design of a building. The purpose of the standards of this section is to ensure that the visual impact of mechanical and utility equipment is minimized. (b) Mechanical Equipment in Building. Mechanical equipment shall be located within the building, unless the applicant demonstrates the equipment is necessary for the function of the building and locating the equipment within the building would conflict with the equipment's function or present a health and safety risk to the occupants of the building. If the mechanical equipment is necessary for the function of the building and locating it within the building would conflict with its function or present a health and safety risk to building occupants, the equipment may be located on the rooftop, on facades, or on horizontal surfaces consistent with the standards of this section. (c) Rooftop Mechanical Equipment. In addition to the meeting the requirements of Section 9-7-7, "Building Height, Appurtenances," B.R.C. 1981, any rooftop mechanical equipment, including without limitation vents, ventilators, skylights, and antennas, and excluding solar energy and wind energy conversion systems, shall meet the following standards: (1) Rooftop mechanical equipment shall be located consistent with one of the following methods: (A) Incorporate equipment into the roof design consistent with the applicable standards of Section 9-14-25, "Cap Types," B.R.C. 1981. (B) Set the equipment back a minimum of twenty feet from any Type A or B frontage facade. (d) Mechanical Equipment on Facades. Mechanical equipment shall not be located on a facade unless the applicant demonstrates that locating the equipment in a different location would conflict with the equipment's function. Any mechanical equipment on a facade, such as dryer vents, gas meters, and air conditioners, shall be located consistent with the following standards: (1) Facade. The mechanical equipment may be located on a non-Type A frontage facade. The equipment and appurtenances may be located on a Type A frontage facade only if the following requirements are met: (A) The equipment is located on a surface perpendicular to any right-of-way; (B) The equipment extends from the facade surface no more than three inches; and (C) The equipment is screened from the sidewalk. (2) Alignment. Multiple pieces of mechanical equipment shall be organized on the facade in a regular pattern and aligned. Compliance with this standard shall be illustrated on the drawing elevations submitted as part of the application. (3) Material Coordination. To the extent practicable, facade-mounted mechanical equipment shall be located on a material that limits their visibility. For example, dark colored vents will be more visible on light colored stucco than a textured, darker surface such as brick. (4) Screening. Mechanical equipment shall be screened from view unless the approving authority finds that such screening conflicts with the function of the equipment. The form, material, and color of the screening shall meet the following criteria: (A) Screening, other than landscaping, is consistent with the building design, colors, and materials; (B) The equipment is placed where it is least visible from adjacent streets; (C) The height of any screen is the minimum appropriate to adequately screen the mechanical equipment; and (D) Screening does not increase the apparent height of the walls of the building. (5) No encroachment. Mechanical equipment shall not extend into any public right-of-way or easement. (e) Mechanical and Utility Equipment on Other Horizontal Surfaces. Mechanical equipment and utility equipment located on the ground, decks, or horizontal surfaces other than the roof, such as, but not limited to, electrical equipment and air conditioners, shall be located consistent with the following standards: (1) All equipment may be located in the parking yard or a Type B Street yard. (2) Equipment may be located in a side yard provided the side yard does not contain or abut a paseo. (3) All equipment shall be screened from view from any public way with landscaping, fencing, or walls consistent with the building design, colors, and materials. (4) The reviewing authority may approve mechanical or utility equipment to located on a Type A street or on a paseo only if the following conditions are met: (A) The applicant demonstrates that the equipment cannot be located in a parking yard, Type B Street yard, or in a side yard that does not contain a paseo. (B) The equipment is fully screened with a wall that is consistent with the building design, colors, and materials and of a height that is the minimum to adequately screen the equipment and that does not prevent the facade from fulfilling any transparency requirements. Ordinance No. 8669 (2025)

Ask a question about Boulder law

Corpus searches the Boulder sections it holds and shows the ones that match, with their citations. Free, no sign-in.