30.08 - SETTING AND ASSEMBLING OF FURNACES.
(1) Assembly. Warm air furnaces shall be located on a solid foundation or support and in a workmanlike manner. All sections and joints shall be properly fitted and sealed gas tight. (2) Casings. Warm air furnaces shall be enclosed in metal casings or equivalent noncombustible material. Sheet metal casings, including plenums or bonnets shall be made of metal sheets not lighter than No. 26 U.S. Standard Gauge, or equal. They shall fit the casings and casing rings closely, so as to be dust tight and shall be securely fastened to the front. The casing shall be lined from the top of the casing down to a line on a level with the grate. When side collars are used, the casing top or bonnet must be of sufficient height so that the largest warm air pipe can be taken from side without ovalling. In no case shall a distance less than eight (8) inches be maintained between the top of the furnace and the top of the bonnet or plenum.