§ 30.03 — GENERAL CONDITIONS
Madison General Ordinances (Rev. 28, Update 3: codified through ORD-26-00040, published August 3, 2026) · Madison General Ordinances § 30.03
Corpus is an independent public-information project, not the official City of Madison website. Stable reference: corpuslaw.us/code/9a1b25e2-127d-4e36-a0fc-77cb715846ed
30.03 - GENERAL CONDITIONS.
(1) Space heaters shall not be installed in any living quarters unless the combustion air supply is taken from the outside directly to the unit. Space heaters which are presently installed without an outside combustion air supply directly to the unit must be removed by June 1, 1975, or shall be provided with an outside combustion air supply directly to the unit by the above specified time. The above subsection shall be enforced over the Wis. Admin. Code Sec. SPS 364.21. All other provisions of Wis. Admin. Code Sec. SPS 364.21 shall apply where applicable. (Am. by Ord. 9298, 10-29-87; ORD-12-00035, 3-28-12) (2) For isolation of fire hazards, refer to the Madison General Ordinances, Sec. 29.20(15)(b). (R. & Recr. by Ord. 4891, 2-13-75) (3) In addition to the requirements contained in the manuals and pamphlets listed in Appendix No. 1 which shall be classed as minimum standards of this code, the installation of all heating equipment and piping shall conform to the requirements set forth in the following sections of this code. (4) Poor workmanship, design or methods of installation likewise shall be sufficient cause for the condemnation of the whole or any part of the system. (5) Combustion Air. (a) One and Two-Family Residences. The provisions herein apply to appliances installed in buildings and which require air for combustion, ventilation, and dilution of flue gases from within the building. They do not apply to (1) sealed combustion system appliances which are installed so that all air for combustion is obtained from the outside atmosphere and all flue gases are discharged to the outside atmosphere, or (2) enclosed furnaces which incorporate an integral total enclosure and use only outside air for combustion and dilution of flue gases. Appliances shall be installed in a location in which the facilities for ventilation permit satisfactory combustion of gas, proper venting and the maintenance of ambient temperature at safe limits under normal conditions of use. Appliances shall be located so as not to interfere with proper circulation of air within the confined space. When buildings are so tight that normal infiltration does not provide the necessary air, outside air shall be introduced. While all forms of building construction cannot be covered in detail, air for combustion, ventilation and dilution of flue gases for gas appliances vented by natural draft normally may be obtained by application of one of three methods listed below: All air from inside buildings. All air from outdoors. Ventilation air from inside buildings - combustion and draft hood dilution air from outdoors. 1. Appliances Located in Unconfined Spaces. In unconfined spaces in buildings of conventional frame, masonry, or metal construction, infiltration normally is adequate to provide air for combustion, ventilation, and dilution of flue gases. If the unconfined space is within a building of unusually tight construction, air for combustion, ventilation, and dilution of flue gases shall be obtained from outdoors or from spaces freely communicating with the outdoors. A permanent opening or openings having a total free area of not less than one (1) square inch per five thousand (5,000) BTU per hour of total input rating of all appliances shall be provided. Ducts may be used to convey make-up air from the outdoors and shall be of the same cross-section area as the free area of the openings to which they connect. The ducts may be connected to the cold air return of the heating system only if they connect directly to the outside air. The minimum dimension of rectangular air ducts shall be not less than three (3) inches. 2. Appliances Located In Confined Spaces. a. All Air From Inside Buildings. The confined space shall be provided with two (2) permanent openings, one (1) commencing within twelve (12) inches of the top and one (1) commencing within twelve (12) inches of the bottom of the enclosure. Each opening shall have a minimum free area of one (1) square inch per one thousand (1,000) BTU per hour of the total input rating of all appliances in the enclosure. The openings must freely communicate with interior areas having in turn adequate infiltration from the outside. b. All Air From Outdoors. The confined space shall be provided with two (2) permanent openings, one (1) commencing within twelve (12) inches of the top and one (1) commencing within twelve (12) inches of the bottom of the enclosure. The openings shall communicate directly, or by ducts, with outdoors or spaces (crawl or attic) that freely communicate with outdoors. When directly communicating with the outdoors each opening shall have a minimum free area of one (1) square inch per four thousand (4,000) BTU per hour of total input rating of all appliances in the enclosure. When communicating with the outdoors through vertical ducts each opening shall have a minimum free area of one (1) square inch per four thousand (4,000) BTU per hour of total input rating of all appliances in the enclosure. When communicating with the outdoors through horizontal ducts, each opening shall have a minimum free area of one (1) square inch per two thousand (2,000) BTU per hour of total input rating of all appliances in the enclosure. When ducts are used, they shall be of the same cross-sectional area as the free area of the openings to which they connect. The minimum dimension of rectangular air ducts shall be not less than three (3) inches. c. Ventilation Air From Inside Buildings - Combustion and Drafthood Dilution Air From Outdoors. The confined space shall be provided with two 2) openings located and sized as in Section 30.03(5)(a)2.a. In addition, there shall be one (1) opening directly communicating with outdoors or spaces (crawl or attic) that freely communicate with outdoors. This opening shall have a minimum free area of one (1) square inch per five thousand (5,000) BTU per hour of total input of all appliances in the enclosure. Ducts may be used to convey make-up air and shall be of the same cross-section area as the free area of the openings to which they connect. The ducts may be connected to the cold air return of the heating system only if they connect directly to outside air. The minimum dimension of rectangular air ducts shall not be less than three (3) inches. (b) (R. by Ord. 10,255, Adopted 5-7-91) (6) Where kitchen and bathroom exhaust ventilation is provided, ductwork shall extend to the exterior of the building. The termination of the ductwork shall be into an approved weatherproof hood.
Ask a question about Madison law
Corpus searches the Madison sections it holds and shows the ones that match, with their citations. Free, no sign-in.