12.43 - Private Wells.

Water Well Supply System All wells as defined in Section 12.01 require approval through the Linn County Public Health's (LCPH) Private Water Well Program and the approval of the City Utilities Director or their designee. Prior to the approval of any well, the well contractor must obtain a private water well construction permit from the LCPH Private Water Well Program and, where applicable, an Iowa Department of Natural Resources water use permit as required by 567 Iowa Administrative Code Chapters 50 - 52 and Iowa Code Chapter 455B, division III, part 4. This section does not apply to a private well in existence on the date of the adoption of this Chapter. The repair and modification of an existing well is also allowed, however, the capacity of an existing well may not be expanded and may be repaired and/or modified only upon receiving a permit from the LCPH Private Water Well Program. All procedures and methods for the construction of a private well must comply with 567 Iowa Administrative Code Chapters 49 (non-public water supply well construction)and 82 (well contractor certification), and with all applicable regulations of the United States Environmental Protection Agency. Wells may not be connected directly or indirectly to the public water supply. Geothermal Well Standards It is the purpose of this Section to protect the health, safety, and general welfare of the people of the City by ensuring that groundwater is not polluted or contaminated. Open Loop Systems: Open loop systems require review and approval by the City Utilities Director or their designee. Closed Loop Systems: Closed loop systems are subject to the requirements contained herein for the construction, reconstruction, repair, and destruction of geothermal wells. The construction of geothermal wells must use construction standards designed to adequately protect the aquifers in each specific geologic setting encountered and in all other criteria, comply with 567 Iowa Administrative Code Chapter 49. All well services must be performed with an Iowa Department of Natural Resources certified well contractor as required by 567 Iowa Administrative Code Chapter 82. The certified well contractor must be on site and in direct control of all well services being performed. Permit Required: Prior to the construction of any geothermal well, the well contractor must obtain a private water well construction permit from the LCPH and a permit from the City Building Services Department, and, where applicable, an Iowa Department of Natural Resources water use permit or registration as required by 567 Iowa Administrative Code Chapters 50 - 55 and Iowa Code Chapter 455B, division III, part 4. No person may dig, bore, drill, replace, modify, repair, or destroy a geothermal well or any other excavation that may intersect groundwater without first applying for and receiving a permit from LCPH and a permit from the Building Services Department. Application Procedure: Applications for building services permits required by this Section must be made on forms provided by the Building Services Department and must contain all such information as required on the form. The application must be submitted by the property owner, the owner's representative, or the well contractor. Minor geothermal systems may be authorized by the Building Official in consultation with the Utilities Director or their designee. Geothermal permits will be reviewed by the Utilities Director or their designee and the Building Official or their designee. Site Plan Requirements: A site plan must be submitted with the application and must: Show the generally proposed location, number of wells, and location of loops; Include descriptions and Material Safety Data Sheets (MSDS) of the heat transfer fluid; Heat transfer fluids must comply with 567 Iowa Administrative Code Section 49.29(5). Propylene glycol must be USP food grade, and any additives must be NSF certified as HT1 for incidental food contact or be NSF 60 certified for drinking water treatment. Include a 1000' radius identifying documented contamination, mapped plumes, aboveground storage tanks, underground storage tanks, and all wells; Include the calculated anticipated volume of grout that will be required; and Show the property boundaries and easements of record and detail where the system is located on the property. All loops must be located within the property boundaries of the building lot and not encroach on any easements. Geothermal pipe loops must be of approved material for geothermal installation, have a fifty (50) year warranty against defects and workmanship, and be installed with a tracer wire. Permit Suspension And Revocation: The Utilities Director or their designee or the Building Official may suspend or revoke any permit issued pursuant to this Section whenever the Utilities Director or their Designee finds any of the following: The permittee has violated any of the provisions of this Section; The permittee has misrepresented any material fact in the application or any supporting documents; The well or its use may pose a risk to groundwater quality, human health, or the environment; or The system fails any of its mandated testing requirements. Abandonment Of Geothermal Systems: Geothermal wells must be abandoned as required in 567 Iowa Administrative Code Section 49.28. The heat transfer fluid must be removed by displacement with grout and the loop pipes properly capped or sealed by an approved method. All heat transfer fluid must be safely disposed of according state and federal regulations. The top of the borehole must also be uncovered and properly capped or sealed by an approved method. Regulation Conflict: In the event any of the provisions of this section conflict with any state or federal regulation, the state or federal regulation will control. Compliance: All procedures and methods for construction of geothermal wells must comply with 567 Iowa Administrative Code Chapters 82 and 49 for nonpublic water supply wells and all applicable regulations of the United States Environmental Protection Agency. Existing Systems: Except for provisions in this subsection (b) regarding replacement, modification, repair, or destruction, this Section does not apply to systems in existence on the date of the adoption of this Chapter. (Note: Chapter 12 repealed and reenacted by Ordinance No. 025-24, passed June 11, 2024)

Ask a question about Cedar Rapids law

Corpus searches the Cedar Rapids sections it holds and shows the ones that match, with their citations. Free, no sign-in.