Sec. 26-321. - Installation requirements.

(a) Backflow prevention assemblies shall be installed in accordance with the following requirements: (1) Backflow prevention assemblies shall be installed in accordance with the Plumbing Code, commission rules, this article, and all other applicable federal, state, and local laws; (2) Backflow prevention assembly installers shall obtain the required plumbing permits prior to installation of any backflow prevention assembly; (3) Backflow prevention assembly installers shall have all backflow prevention assemblies tested and inspected in accordance with applicable laws; (4) All backflow prevention assemblies shall be protected from freezing and other severe weather conditions on a year-round basis; (5) All backflow prevention assemblies shall be of a type and model approved by: (i) the building official during construction, renovation, or alteration of any buildings or structures regulated under chapter 17 of the Code of the City of Denton, Texas; or (ii) the director in all other situations, and (6) Any installation orientation not approved by the manufacturer of the backflow prevention assembly is prohibited. (b) When the director requires an approved backflow prevention assembly to be installed at the service connection of both potable and reclaimed water supplies, such installation of the assembly shall be immediately behind the meter on the customer's side of the meter. If this is not possible, the assembly must be as close as possible to the meter and installed before any branch in the line and on private property located just inside the boundary between the city right-of-way and the premises. (c) Backflow prevention assemblies that are larger than four (4) inches and are installed more than four (4) feet above floor level shall be equipped with a rigid and permanently installed scaffolding acceptable to the director. (d) Bypass lines are prohibited. Pipe fittings that could be used for connecting a bypass line shall not be installed. (e) Premises that require backflow prevention assemblies and where an uninterrupted, continuous water supply is critical shall be provided with two (2) approved backflow prevention assemblies. The approved backflow prevention assemblies must be installed in parallel to facilitate testing, maintenance, and repair. The approved backflow prevention assemblies must be sized so that either assembly can individually provide the maximum flow required. (f) The director shall be notified when installation of a backflow prevention assembly is complete. All backflow prevention assemblies shall be inspected and tested pursuant to this article. All tests shall be submitted online through the city's approved website or as directed by the director. (g) A user commits an offense if the user: (1) Installs, or arranges for the installation of, a backflow prevention assembly in violation of this article; (2) Fails to notify the director of the installation of a backflow prevention assembly; (3) Fails to inspect or test, or cause the inspection or testing of, any backflow prevention assembly in accordance with this article; or (4) Fails to submit a test report form in compliance with this article.

(Ord. No. 25-1726, § 3(Exh. A), 3-24-26)

Ask a question about Denton law

Corpus searches the Denton sections it holds and shows the ones that match, with their citations. Free, no sign-in.