33.120.280 Detached Accessory Structures
A. Purpose. This section regulates detached structures that are incidental to primary buildings
to prevent them from becoming the predominant element of the site. The standards limit
the height and bulk of the structures and promote compatibility of design for larger
accessory structures when they are in conjunction with single-dwelling development. The
standards provide for necessary access around structures, help maintain privacy to abutting
lots, provide flexibility for the location of accessory structures, and maintain open front yard
areas.
B. General standards.
1.
The regulations of this section apply to all accessory structures. Additional regulations
for accessory dwelling units are stated in Chapter 33.205.
2.
Detached accessory structures are allowed on a site only in conjunction with a primary
building and may not exist on a site prior to the construction of the primary structure,
except as allowed by Paragraph B.3, below.
3.
A detached accessory structure that becomes the only structure on a lot as the result
of a land division, a property line adjustment, a lot confirmation, or a demolition of
the primary structure may remain on the lot if the owner has executed a covenant
with the City that meets the requirements of Section 33.700.060.
a.
For a land division, the covenant must require the owner to remove the
accessory structure if, within two years of final plat approval, a primary structure
has not been built and received final inspection. The covenant must be executed
with the City prior to final plat approval.
b.
For a property line adjustment or a lot confirmation, the covenant must require
the owner to remove the accessory structure if a primary structure has not been
built and received final inspection within two years. The two years begins on the
date the letter from PP&D approving the property line adjustment or lot
confirmation is mailed. The covenant must be executed with the City before the
final letter from PP&D is issued.
c.
For a demolition of a primary structure, the covenant must require the owner to
remove the accessory structure if a new primary structure has not been built and
received final inspection within two years of the demolition of the old primary
structure. The two years begins on the date of the final inspection of the
demolition. The covenant must be executed with the City prior to the issuance of
the demolition permit.
C. Detached covered accessory structures. Detached covered accessory structures are items
such as garages, greenhouse, artist’s studios, guest houses, accessory dwelling units,
laundry or community buildings, storage buildings, covered bicycle parking, wood sheds,
water collection cisterns, and covered decks or patios. The following standards apply to all
detached covered accessory buildings. Garages are also subject to the standards of
33.120.283.
1.
Height. In general, the height standard of the base zone apply to detached covered
accessory structures. The maximum height allowed for detached covered structures
that are accessory to a house, attached house, duplex, attached duplex or
manufactured home on an individual lot is 20 feet.
2.
Setbacks. Except as follows, detached covered accessory structures are subject to
required building setbacks. See the additional regulations for garages in 33.120.283.
a.
Water collection cisterns that are 6 feet or less in height are allowed in side and
rear setbacks.
b.
Detached covered accessory structures are allowed in the side and rear building
setbacks, if all of the following are met:
(1) The structure is at least 10 feet from a street lot line or no closer to a street
line than the closest primary building, whichever distance is greater;
(2) The structure’s footprint has dimensions that do not exceed 24 feet by 24
feet, excluding eaves;
(3) If more than one structure is within the setback, the combined length of all
structures in the setback adjacent to each property line is no more than
24 feet;
(4) The structure is no more than 15 feet high, and the walls of the structure
are no more than 10 feet high, excluding the portion of the wall
within a gable;
(5) The portion of the structure within the setback must be screened from
adjoining lots by a fence unless it is enclosed within the setback by a wall.
Screening is not required for enclosed structures. Screening must comply
with the F2 standards of Chapter 33.248, Landscaping and Screening;
(6) Walls located within the setback may not have doors or windows facing the
adjacent lot line;
(7) The structure does not have a rooftop deck; and
(8) Dormers are set back at least 5 feet from the side and rear lot lines that
abut another lot.
3.
Building coverage. The following additional building coverage standards apply to
detached covered accessory structures.
a.
The combined building coverage of all detached covered accessory structures
may not exceed 20 percent of the total area of the site.
b.
The building coverage of a detached covered accessory structure may not be
greater than the building coverage of the primary structure.
4.
Additional development standards for detached covered accessory structures. The
following additional standards apply to detached covered accessory structures that
are more than 15 feet high, and are accessory to houses, attached houses, duplexes,
attached duplexes, manufactured homes, triplexes, or fourplexes on individual lots.
Additions to existing structures that do not meet a standard are exempt from that
standard.
a.
Exterior Finish Materials. The exterior finish materials on the detached covered
accessory structure must meet one of the following:
(1) The exterior finish material must be the same or visually match in type, size
and placement, the exterior finish material of the primary structure; or
(2) Siding must be made from wood, composite boards, vinyl or aluminum
products, and the siding must be composed in a shingle pattern, or in a
horizontal clapboard or shiplap pattern. The boards in the pattern must be 6
inches or less in width.
b.
Roof Pitch. The pitch of the roof with the highest ridgeline on the detached
covered accessory structure must meet one of the following:
(1) The pitch of the roof with the highest ridgeline must be the same as the
pitch of the roof with the highest ridgeline of the primary structure; or
(2) The pitch of the roof with the highest ridgeline must be at least 6/12.
c.
Trim. The trim on the detached covered accessory structure must meet one of
the following:
(1) The trim must be the same in type, size, and location as the trim used on
the primary structure; or
(2) The trim around all windows and doors must be at least 3 ½ inches wide.
d.
Windows. The windows on all street facing facades of the detached covered
accessory structure must meet one of the following:
(1) The windows must match those on the street facing façade of the primary
structure in orientation (horizontal or vertical); or
(2) Each window must be square or vertical – at least as tall as it is wide.
e.
Eaves. The eaves on the detached covered accessory structure must meet one of
the following:
(1) The eaves must project from the building walls the same distance as the
eaves on the primary structure;
(2) The eaves must project from the building walls at least 1 foot on all
elevations; or
(3) If the primary structure has no eaves, no eaves are required.
D. Detached uncovered vertical structures. Vertical structures are items such as flag poles,
trellises, arbors, and other garden structures, play structures, antennas, satellite receiving
dishes, detached structures that hold electric vehicle chargers, and lamp posts. The
following standards apply to uncovered vertical structures. Fences are addressed in Section
33.120.285 below:
1.
Height. Except as follows, the maximum height allowed for all detached uncovered
vertical structures is the maximum height of the base zone. The maximum height
allowed for detached uncovered vertical structures that are accessory to a house,
attached house, duplex, attached duplex or manufactured home on an individual lot is
20 feet:
a.
Antennas, utility power poles, and public safety facilities are exempt from
height limits.
b.
Flagpoles are subject to the height limit of the base zone for primary structures.
c.
Detached small wind turbines are subject to the standards of 33.299.
2.
Setbacks. Except as follows, detached uncovered vertical structures are subject to the
required building setbacks:
a.
Detached uncovered vertical structures that are no larger than 3 feet in width,
depth, or diameter and no taller than 8 feet are allowed in required
building setback.
b.
A single arbor structure that is up to 6 feet wide, up to 3 feet deep, and up to 8
feet tall is allowed in a front setback. The arbor must allow for pedestrian access
under its span.
c.
Flagpoles are allowed in required building setbacks.
d.
Detached uncovered vertical structures that exceed the allowances of
Subparagraph 2.a are allowed in side and rear setbacks if all of the following are
met:
(1) The structure is at least 40 feet from a front lot line, and if on a corner lot, at
least 20 feet from a side street lot line;
(2) The structure’s footprint has dimensions that do not exceed 24 feet by 24
feet; and
(3) The structure is no more than 10 feet high;
(4) The portion of the structure within the setback must be screened from
adjoining lots by a fence or landscaping, unless it is enclosed within the
setback by a wall. Screening is not required for enclosed structures.
Screening must comply with the L3 or F2 standards of Chapter 33.248,
Landscaping and Screening; and
(5) The structure does not have a rooftop deck.
3.
Additional standard for detached uncovered vertical structures that hold electric
vehicle chargers. In addition to Paragraphs 1. and 2. above, a detached uncovered
vertical structure that holds at least a Level 2 electric vehicle charger must be located
so that the electric vehicle charger is within 5 feet of a vehicle area.
E. Detached uncovered horizontal structures. Uncovered horizontal structures are items such
as decks, stairways, swimming pools, hot tubs, tennis courts, and boat docks not covered or
enclosed. The following standards apply to detached uncovered
horizontal structures:
1.
Height. In general, the maximum height allowed for detached uncovered horizontal
structures is the maximum height of the base zone. The maximum height allowed for
detached uncovered horizontal structures that are accessory to a house, attached
house, duplex, attached duplex or manufactured home on an individual lot is 20 feet.
2.
Setbacks. Except as follows, detached uncovered horizontal structures are subject to
the required building setbacks:
a.
Detached uncovered decks, ramps, and stairways that are more than 2-1/2 feet
above the ground may extend into a required building setback up to 20 percent
of the depth of the setback. However, the deck or stairway must be at least three
feet from a lot line.
b.
Structures that are no more than 2-1/2 feet above the ground are allowed in all
building setbacks.
F.
Detached mechanical equipment. Mechanical equipment includes items such as heat
pumps, air conditioners, emergency generators, radon mitigation components, and water
pumps. Generally, detached mechanical equipment will not be attached to the building but
may have components such as ventilation or electrical systems attached to the primary
structure. The following standards apply to detached mechanical equipment:
1.
Height. In general, the maximum height allowed for detached mechanical equipment
is the maximum height of the base zone. The maximum height allowed for detached
mechanical equipment that is accessory to a house, attached house, duplex, attached
duplex or manufactured home on an individual lot is 20 feet.
2.
Setbacks. Except as follows, detached mechanical equipment is subject to required
building setbacks. Detached mechanical equipment accessory to a house, attached
house, duplex, attached duplex, manufactured home, triplex, or fourplex on an
individual lot is allowed in side or rear building setbacks if all of the following are met:
a.
The equipment is no more than five feet high; and
b.
The equipment is screened from the street and adjoining lots by walls, fences or
vegetation. Screening must comply with the L3 or F2 standards of Chapter
33.248, Landscaping and Screening.