30.05 - ACTIVE SOLAR COLLECTOR SYSTEMS.

(1) Orientation Guidelines. (a) For solar systems used only for winter space heating, the collector tilt angle measured from the horizontal shall be 55° to 90°, and the azimuth angle measured from due south shall be 25° or less. (b) For solar systems which are not utilized during the months of November, December, January, or February, the collector tilt angle measured from the horizontal shall be 14° to 45°, and the azimuth angle measured from due south shall be 35° or less. (c) For solar systems used the entire year for space heating or water heating, the collector tilt angle measured from the horizontal shall be 45° to 60°, and the azimuth angle measured from due south shall be 30° or less. (d) Any variations from the orientation guidelines above must be consented to and acknowledged by the owner in writing prior to installation of the solar system. (Am. by ORD-08-00122, 11-22-08) (2) (R. by ORD-08-00122, 11-22-08) (3) Collector Mounting. Every solar collection system shall be securely anchored to prevent damage to the collector(s) and structure to which they are attached. Fully engineered mounting and rack details showing collector attachment and support anchorages shall be approved by the Department before installation. The collectors shall be installed according to the manufacturer's instructions. (4) Roof Support. Every solar collection system installed on a roof shall be analyzed to determine if the roof system is strong enough to support the collector system and any anticipated snow loads. Details showing roof structure reinforcements shall be approved by the Department before installation. (5) Corrosion. All materials used in the manufacturing and installation of active solar systems shall be of corrosion-resistant material. All connections shall be made with compatible materials. (6) Sensors. All sensors and controllers installed in active solar systems shall be located to provide for servicing, be installed according to the control manufacturer's instructions and be protected from damage. All sensor wiring shall be securely attached and protected from damage and moisture. (7) Liquid Systems - Piping and Penetration. (a) When three (3) or more collectors are installed in any one system, a reverse flow piping configuration shall be used unless an alternate flow configuration is recommended by the manufacturer. (b) No permanent piping shall connect the solar system with potable water. (c) All piping used in the solar loop supply and return and within ten (10) feet of the collector shall be made and assembled of materials that can withstand antifreeze solution at temperatures of up to 350°F. The remaining solar loop piping shall be made and assembled of materials that can withstand antifreeze solution of 200° F. Note: CPVC Piping has performed poorly in certain installations. (d) All solar loop building penetrations shall be made using weatherproof devices which will allow for expansion and contraction. All penetrations into the building shall be weatherproofed to prevent leaks, insects and drafts from entering the building. (e) All of the components of a closed loop solar collector system shall be sized to provide adequate flow to the collectors. (f) The solar loop shall incorporate a check valve downstream of the heat exchanger if collectors are mounted above the storage tank. (g) Automatic air vents shall be disconnected from the solar loop by a ball valve. (8) Air Systems: Ducting and Penetration. (a) All ducts used in the solar loop shall be made and assembled of materials that will not distort or deteriorate from temperature, pressure, or exposure. (b) All solar loop duct building penetrations shall be made using weatherproof devices which will allow for expansion and contraction. All penetrations into the building shall be weatherproofed to prevent leaks, insects and drafts from entering the building. (c) All of the components of a solar collector duct system shall be sized to provide adequate airflow to the collectors. (d) The solar loop ductwork from the mechanical equipment (i.e. risers to the collector(s), and manifold(s) if used) shall be leak tested with a calibrated blower and the recorded leakage at one-inch water column shall not exceed ten percent (10%) of the system design airflow rate. Note: The City will accept silicone caulk, Hard Cast or equivalent as sealants for metal ducts and Sheet Metal and Air Conditioning Contractor's National Association (SMACNA) approved aluminum tape or approved equivalent as sealants for fiberglass ducts. All ducts in unconditioned spaces shall be sealed with one of the above. Duct tape is not approved for solar application. (e) All ductwork shall be fabricated and installed to meet SMACNA standards. (f) Back-draft dampers or motorized dampers shall be installed so as to prevent air passage through the collectors except when solar energy is being collected. (g) The system shall be designed and installed to prevent cold airflow across the water heating coil. If mechanical dampers are used to meet this requirement, they shall meet a leakage test not to exceed five percent (5%) of the system design air flow rate at one-inch water column. (h) All systems shall incorporate a secondary freeze protection system in case of mechanical failure. An electrical freeze sensor which activates the pump to circulate fluid through the domestic coil will meet this requirement. (i) Systems incorporating domestic heating shall be equipped with a summer bypass to the solar storage during the non-heating season. (j) All air systems used for space heating shall incorporate the use of a high efficiency air filter installed in the cold air riser duct to the collectors. The air filter shall have a minimum average efficiency of thirty percent (30%) as rated by the filter manufacturer. (9) Liquid Systems - Pipe Insulation. (a) All pipe insulation in the solar collection system shall be at least R-5 in insulating value. (b) Exterior pipe insulation shall resist ultraviolet and environmental degradation and shall be covered by material providing weather resistance, UV protection and mechanical abuse protection. Exterior insulation joints, seams and connections shall be sealed to prevent entry of moisture. Fiberglass and elastomer insulation shall not be used for exterior solar application. (c) Solar supply loop shall be insulated with three hundred degree (300°F) rated insulation approved for solar applications. Note: One-inch thickness of urethane and phenolic foam, with appropriate cover will meet the requirements of Subsection (b) above. (10) Air Systems - Duct Insulation and Piping. (a) Ductwork located in unheated spaces shall be insulated to a minimum value of R-7. (b) Ductwork located in heated spaces shall be insulated to a minimum value of R-3. Note: It is recommended that all duct chases be insulated to a minimum insulating value of R-11. Some acceptable materials for insulation include: fiberglass duct wrap, fiberglass duct liner, fiberglass duct board. (c) A vapor barrier, if installed, shall not be located on the cold side of the ductwork. (d) All domestic water piping used in conjunction with a solar air system shall meet the piping requirements for liquid systems. Exception: The cold-water inlet to the storage tank need not be insulated beyond two (2) feet from the storage tank. (11) Heat Transfer Fluids. (a) Every solar collection system using fluids for heat transfer shall have a label attached to the storage/transfer tank indicating what fluid is contained in the collection system, its freezing point, Ph and installation date. (b) The fluid contained in a non-drain down system shall be able to withstand temperatures of at least -30°F before freezing. (c) Instructions shall be attached to the system indicating the fluid manufacturer's recommendations for proper checking and maintenance procedure. (d) Only fluids recommended by the manufacturer for use in solar systems shall be used in solar systems. Ethylene glycol shall not be used for solar systems due to its toxicity. (e) The heat transfer fluid used in the collectors shall be isolated from the potable water supply through the use of an approved double wall heat exchanger. (12) Valves, Vents and Dampers. (a) Adequately sized pressure relief valves shall be located on all storage tanks within the system. The pressure relief valve shall be piped to discharge fluids within ten (10) inches of the floor. (b) All closed loop solar collector systems filled with antifreeze fluids shall be provided with a bleed valve installed at the highest point in the piping system. (c) All closed loop solar collection systems shall be provided with a pressure relief valve in the solar loop piping. The relief valve shall be piped to a safe location to avoid personal injury or damage to the building. (d) All closed loop solar collector systems filled with antifreeze fluid shall be pumped from the bottom of the collector array to the top of the collector array during normal operation. A check valve shall be provided in the system to prevent flow in the opposite direction. (e) Controls, dampers and valves shall be marked to identify their function. (13) Storage Tanks - Liquid Systems. (a) Storage tanks shall be located in heated (+50°F) areas whenever possible. (b) Storage tanks located in unheated areas (+49°F or less) shall be insulated to an overall value of R-20 or greater. The insulation shall be permanently fastened in place. (c) Storage tanks installed in heated spaces shall be insulated to an overall value of R-11 or greater. The insulation shall be permanently fastened in place. (d) Heat traps shall be included on all supply and discharge lines for the storage tank. (Cr. by ORD-08-00122, 11-22-08) (e) Storage tanks shall be located to provide for proper servicing. (f) All storage tanks shall be designed and installed to withstand all anticipated loads and environmental conditions. (g) All air vented tanks shall be covered. (Sec. 30.05(13)(d)-(f) Renum. to (e)-(g) by ORD-08-00122, 11-22-08) (h) Storage tanks shall have a tempering valve adjustable to 120°F downstream from the regular water heater and heat trap. (Cr. by ORD-08-00122, 11-22-08) (14) Storage - Air Systems. (a) Storage systems shall be located in heated (+50°F) areas whenever possible. (b) Storage systems located in unheated areas (+49°F or less) shall be insulated to an overall value of R-38 or greater. The insulation shall be permanently fastened in place. (c) Storage systems installed in heated spaces shall be insulated to an overall value of R-11 or greater. The insulation shall be permanently fastened in place. (d) All storage systems shall be designed and installed to withstand all anticipated loads and environmental conditions. (e) If rock is utilized for thermal storage, it shall be washed before it is placed into the storage area. (f) If phase change storage materials are utilized in an air storage system, the storage materials shall be placed in sealed containers. (g) When a rock storage system is utilized, an inlet plenum and an outlet plenum shall be provided. (15) Monitoring and Manuals. (a) Every active liquid solar system shall have a thermometer installed on the storage tank, to measure the temperature of the fluid in the storage tank. A single tank system would not be considered as having a storage tank. (b) A pressure gauge shall be installed in the solar loop. (Cr. by ORD-08-00122, 11-22-08) (c) The solar loop supply and return and the discharge line of the tempering valve shall have thermometers. (Cr. by ORD-08-00122, 11-22-08) (d) Arrows shall be placed on the piping/ducting of the solar collector loop to indicate the direction of the fluid/air flow. (Renum. by ORD-08-00122, 11-22-08) (e) Suppliers and installers of solar systems shall supply manuals to the owner explaining the operation and maintenance of the installed solar equipment. The manufacturer's name and model number of all major components shall be furnished to the owner. (Renum. by ORD-08-00122, 11-22-08) (16) Site Built and Non-Standard Systems. The intent of this code is not to inhibit or discourage site built and non-standard systems but to insure that they are adequately designed and installed. Site built collectors shall conform to the provisions of this code, except 30.01(10)(c)7.b.

(Sec. 30.05(7) Am. by ORD-08-00122, 11-22-08) (Sec. 30.05(9) Am. by ORD-08-00122, 11-22-08) (Sec. 30.05 Cr. by Ord. 8348, 5-25-84; Sec. 30.05(5) Rep., Secs. 30.05(6) through (17) Renum. (5) through (16) by ORD-08-00122, 11-22-08)

Ask a question about Madison law

Corpus searches the Madison sections it holds and shows the ones that match, with their citations. Free, no sign-in.