§ 50.11. - General service facilities.

(a) General service customers shall supply, install and maintain all underground secondary service cable. General service customers shall also supply the utility side secondary terminal connectors for installation by CWLP. All underground ducts, manholes, vaults, and transformer equipment pads located on the customer's premises shall be furnished and installed by the customer per CWLP specifications. Primary cables and transformers will be furnished and installed by the utility. (b) When the customer requests and the utility agrees to install primary metering, the customer shall be responsible for furnishing and maintaining all facilities on the customer's side of the primary meter. (c) For overhead services the customer is responsible to supply, install and maintain the service conduit riser, service weatherhead, metering conduit, metering conduit weatherhead, instrument transformer cabinet and service entrance cable from the main breaker or disconnect to the connection point at the weatherhead. The utility shall supply the current transformers, potential transformers and instrument rated meter socket to the customer for a fee (as provided in the "Rules and Specifications for Electric Service") for installation by the customer. If an instrument transformer bracket is used in lieu of an instrument transformer cabinet, the utility will supply the bracket. Self-contained meter sockets shall be supplied and installed by the customer per CWLP specifications and standards. The utility shall supply and install the instrument transformer wiring and electric meter for the service. (d) For underground services the customer is responsible to supply, install and maintain the service conduit and secondary service cables from the utility service point, typically a distribution pedestal or transformer, to the main breaker or disconnect. For instrument rated services where the instrument transformers are mounted on the building or structure, the customer must supply, install and maintain the metering conduit and instrument transformer cabinet. The utility shall supply the current transformers, potential transformers and instrument rated meter socket to the customer for a fee (as provided in the "Rules and Specifications for Electric Service") for installation by the customer. For instrument rated services where the instrument transformers are mounted in the transformer, the utility shall supply and install the current transformers, potential transformers and instrument rated meter socket for a fee (as provided in the "Rules and Specifications for Electric Service"). Self-contained services meter sockets shall be supplied and installed by the customer per CWLP specifications and standards. In all cases the utility shall supply and install the instrument transformer wiring and electric meter for the service. (e) City water, light and power is responsible for removing and reinstalling an electric meter on overhead and underground services.

(Ord. No. 226-7-12, Exh. A, 7-3-12)

Ask a question about Springfield law

Corpus searches the Springfield sections it holds and shows the ones that match, with their citations. Free, no sign-in.