18.70.030 - Definitions.
Notwithstanding the applicable definitions, symbols and notations in this title, the following definitions shall apply for the purposes of this chapter:
"Apartment house" means any building or portion thereof which contains three (3) or more dwelling units, and for the purposes of this chapter, includes residential condominiums.
"Aspect ratio" means the ratio of the height of a wall section to its width.
"Congregate residence" means any building or portion thereof which contains facilities for living, sleeping and sanitation, as required by this code, and may include facilities for eating and cooking, for occupancy by other than a family. A congregate residence may be a shelter, convent, monastery, dormitory, and fraternity or sorority house but does not include jails, hospitals, nursing homes, hotels or lodging houses.
"Cripplewall" means a wood-framed stud wall extending from the top of the foundation wall to the underside of the lowest floor framing.
"Dwelling unit" means any building or portion thereof which contains living facilities, including provisions for sleeping, eating, cooking and sanitation, as required by this code, for not more than one (1) family, or congregate residence for ten (10) or fewer persons.
"Expansion anchor" means an approved mechanical fastener placed in hardened concrete, designed to expand in a self-drilled or pre-drilled hole of a specified size and engage the sides of the hole in one (1) or more locations to develop shear and/or tension resistance to applied loads without grout, adhesive or drypack.
"Ground floor" means any floor within the wood frame portion of a building whose elevation is immediately accessible from an adjacent grade by vehicles or pedestrians. The ground floor portion of the structure does not include any level that is completely below adjacent grades.
"Guest room" means any room or rooms used or intended to be used by a guest for sleeping purposes. Every one hundred (100) square feet of superficial floor area in a congregate residence shall be considered a guest room.
"Hotel" means any building containing six (6) or more guest rooms intended or designed to be used, rented, hired out to be occupied, or which are occupied for sleeping purposes by guests.
"Level" means a story, basement or under floor space of a building with cripple walls exceeding four feet (4') in height.
"Lodging house" means any building or portion thereof containing at least one (1) but not more than five (5) guest rooms where rent is paid in money, goods, labor or otherwise.
"Motel" means a hotel as defined in this chapter.
"Multi-unit residential buildings" means hotels, lodging houses, congregate residences and apartment houses.
"Nonconforming structural materials" means wall bracing materials for seismic loads whose allowable shear value was reduced or whose maximum allowable aspect ratio was decreased since the original building construction. These methods or materials include, but are not limited to cement or gypsum plaster, gypsum wall board, diagonal or let-in bracing, straight or diagonal wood sheathing, particle board and structural wood panels.
"Open front wall line" means an exterior wall line without vertical elements of the lateral-force-resisting system which requires tributary seismic forces to be resisted by diaphragm rotation or excessive cantilever beyond parallel lines of shear walls. Diaphragms that cantilever more than twenty-five percent (25%) of the distance between lines of lateral-force-resisting elements shall be considered excessive. Exterior exit balconies of six feet (6') or less in width shall not be considered excessive cantilevers.
"Retrofit" means an improvement of the lateral-force-resisting system by alteration of existing structural elements or addition of new structural elements.
"Soft wall line" means a wall line whose lateral stiffness is less than required by story drift limitations or deformation compatibility requirements of this chapter. In lieu of analysis, this may be defined as a wall line in a story where the story stiffness is less than seventy percent (70%) of the story above for the direction under consideration.
"Story strength" means the total strength of all seismic-resisting elements sharing the same story shear in the direction under consideration.
"Wall line" means any length of a wall along a principal axis of the building used to provide resistance to lateral loads. Parallel wall lines separated by less than four feet (4') shall be considered one wall line for the distribution of loads.
"Weak wall line" means a wall line laterally braced with nonconforming structural materials or a wall line in a story where the story strength is less than eighty percent (80%) of the story above in the direction under consideration.