30.28 - RESIDENTIAL AIR CONDITIONING.
(1) Scope. This section is intended to insure safety of operation and the location of the components in conjunction with the heating and cooling or cooling systems of one (1) and two (2) family residences where central air conditioning is employed. (2) Central Air Conditioning Systems (Existing System). When air conditioning is added to an existing heating system, the air volume shall be maintained so the BTU room requirement will be satisfied during the heating cycle. (3) Controls. On all heating and cooling systems, the fan and limit switch shall be located between the heat exchanger and the cooling coil. (4) Wiring. All wiring shall comply with the City of Madison Electrical Code, Chapter 19, of the Madison General Ordinances. (5) Manufacturer's Name and Rating Plate. Manufacturer's name and rating plate shall be affixed to all units. (6) Location of Condensing Unit. A plot plan shall be submitted with application for a permit showing the location of the condensing unit. The condensing unit shall not be located in the required front or side yards. (7) Foundation for Condensing Unit. All units shall be placed on a level waterproof and fireproof base and on well-tamped earth. (8) Refrigerants. ARI Group 2 refrigerants shall not be used for residential air conditioning (ammonia, dischloroethylene, methyl or ethyl chloride, methyl formate and sulphur dioxide). Substitutes of refrigerants shall not be made. (9) Piping. Joints are to be made by braising or by mechanical joints. Joints to be made by soldering shall be made only with materials that melt at temperatures above four hundred (400) degrees Fahrenheit. Soft annealed copper tubing used for refrigerant piping erected on the premises shall not be used in sizes larger than one and three-eighths (1⅜) inches Standard Size (1.375 outside diameter). Mechanical joints shall not be used on soft annealed copper tubing on sizes larger than seven-eighths (⅞) inch Standard Size (0.875 outside diameter). It shall conform to ASTM Specifications B280-62. (10) Installation of Piping. All pipe shall be strapped to the ceiling and free of kinks. The unused portion of precharge or factory furnished pipe shall be strapped to the ceiling in a workmanlike manner. All holes to the exterior shall be sealed tightly. (11) Location of Evaporator. The evaporator coil shall be located upstream of the heating equipment. (12) Condensate Drain. The condensate drain shall be installed according to City of Madison Plumbing Code, Chapter 18, of the Madison General Ordinances.
Ask a question about Madison law
Corpus searches the Madison sections it holds and shows the ones that match, with their citations. Free, no sign-in.