30.10 - RETURN AIR DUCT CONSTRUCTION.

(1) Materials, Return Air Ducts. All return air ducts, except as required by Section 30.10(8) may be constructed of metal or one (1) inch (nominal) wood boards, or other suitable material, provided that no material more flammable than one (1) inch wood boards shall be used. (2) Return Air Ducts Within Two (2) Feet of Furnace. Portions of return air ducts within two (2) feet horizontal distance of the outer jacket shall be constructed of incombustible material. (3) (a) Return Air Ducts in Floors, Walls, Partitions. Where return air ducts are installed in walls, floors or partitions, their installation shall comply with the provisions of Section 30.10(8) regarding firestopping. (b) Insulation of Return Air Ducts Located in or Adjacent to Cold Spaces. Where return air ducts are located in or adjacent to cold spaces, they shall be insulated with at least one (1) inch thickness of insulation and an inspection shall be made of the insulation before the work is concealed. (4) Joist Spaces Used as Return Air Ducts. Where spaces between joists in floors are used as ducts, the portions of such spaces so used shall be cut off from all remaining unused portions by tight fitting stops of sheet metal or of wood not less than a two (2) inch thickness. (5) Combustible Return Air Duct Space Linings. The interior of combustible ducts shall be lined with incombustible material at points where there might be danger from incandescent particles dropped through the register or heater, such as directly under floor registers and the bottom of vertical ducts or directly under a heater having a bottom return. (6) One Grille to Each Stack. No vertical stud space shall have openings to receive return air from more than one (1) level, except where high sidewall returns for air conditioning are required, then a low sidewall or baseboard return air grille with a damper shall be installed. (7) Underfloor Return Air Plenums. Return air shall be conducted to the heater through continuous ducts, except that underfloor spaces may be used as ducts for return of air from rooms directly above, provided such spaces are not over two (2) feet in height to bottom of floor joists and are cleaned of all combustible material and are tightly and substantially enclosed. (8) Bridging and Panning in Return Air Joist Spaces. Whenever the space between joists is used to convey return air overhead, all bridging shall be removed and a dustproof bottom shall be constructed. If more area is required, two (2) or more spaces may be used or a pan may be constructed to extend below the joist to obtain the required area. (9) Gravity Return Air Grille Height Above Floor. Where a vertical gravity return air face is used, the open work or face must extend to within at least one (1) inch of the floor line and not more than fourteen (14) inches high.

(Sec. 30.10(3) Am. by Ord. 6278, 6-15-78)

Ask a question about Madison law

Corpus searches the Madison sections it holds and shows the ones that match, with their citations. Free, no sign-in.