§ 30.04 — ELECTRIC SPACE HEATING
Madison General Ordinances (Rev. 28, Update 3: codified through ORD-26-00040, published August 3, 2026) · Madison General Ordinances § 30.04
Corpus is an independent public-information project, not the official City of Madison website. Stable reference: corpuslaw.us/code/de7a0b3b-2bf3-465d-9350-8f7778a9f395
30.04 - ELECTRIC SPACE HEATING.
The construction, arrangement, installation, alteration, repair and servicing of equipment which directly converts electrical energy into heat energy shall be governed by the provisions set forth, when such equipment is installed as a heating system intended to heat any space, room, or building for the comfort, health, or welfare of the occupants. (1) Requirement for Equipment. (a) All heat generating and emission units, and all control devices shall be in accordance with the Standard for Safety of Electric Heating Appliances established by Underwriters' Laboratories, Incorporated, or any other nationally recognized inspection board or laboratory. (b) The total rating (or adjusted rating) of heat emission devices in each room or space to be heated shall equal or exceed the calculated heat loss of such room or space. (c) The total rating (or adjusted rating) of the heat emission devices shall equal or exceed the calculated aggregate heat loss of all rooms or spaces heated where used as living quarters. The output of each heat generating and emission unit shall be computed at the location where the electrical energy is converted to heat energy. The conversion of electrical energy to heat energy shall be considered at not greater than 3413 BTU kilowatt hour. (d) All heat generating and emission units are to be considered as constant loads and the conductor shall be capable of carrying one hundred twenty-five percent (125%) of the rated current. Where the labeled voltage of a heat generating or emission unit is greater or less than five percent (5%) of the service voltage, an adjusted rating of the heat generating or emission unit shall be used in determining the output. Adjusted | - | (Service Voltage)2 | x | Nameplate Rating (Label Voltage) 2 (2) Electrical Service Capacity. When the primary or exclusive source of energy for space heating is electrical, and the energy is converted directly from electrical energy, the minimum installed electrical service for heating shall equal in kilovolt ampere capacity the total calculated heat loss of the living quarters of the building design conditions. This will require that service conductors and service equipment capacity be provided to supply the total equivalent kilovolt ampere necessary to effect the calculated heat loss, regardless of whether heating devices are installed in all rooms or spaces regarded as living quarters in the initial installation. The service capacity shall be designed to accommodate the heating load in addition to the normal connected load of the building. Load Limitations of Circuits. 1. No single heating unit (except floor furnaces or forced air heaters) of more than five (5) kilowatts shall be installed in any one room of a building. Where the calculated heat loss of room exceeds the equivalent capacity of a five (5) kilowatt heating unit (except floor furnaces and forced air heaters) there shall be installed two (2) or more heating units per room. 2. All electric heating units of more than one thousand six hundred fifty (1,650) watts rated capacity shall be equipped with two hundred thirty-two (232) forty (40) volt single phase elements, except in areas where the nominal standard is two hundred eight (208) volts. Heating units served at one hundred twenty (120) volts shall not exceed one thousand six hundred fifty (1,650) watts each or an aggregate capacity of three thousand three hundred (3,300) watts. 3. Receptacles installed in electric heating units shall not be connected to the heating circuit. (3) Nameplate Required (All Systems). The manufacturer's nameplate shall be attached to the heating unit in a location which is accessible when the unit is in the installed position. The nameplate shall indicate the manufacturer's name, and the rating in amperes or watts and the voltage of the unit. (4) General Installation Requirements. (a) All appliances shall be located in such a manner that continuous operation of the appliance will not raise the temperature of surrounding combustibles more than ninety (90) degrees above normal room temperature, when measured with mercury thermometers or conventional bead-type thermocouples. (b) All stationary or fixed electric heaters shall be permanently connected. (c) Every electrical heating device shall have a manual means for disconnecting all ungrounded conductors. A branch circuit switch pullout, or circuit breaker may be used as the disconnecting means if readily accessible to the user. Thermostats which are an integral part of the heater may not be used as the sole disconnect. One of the following disconnecting means shall be required in addition to such switch. 1. Single-family dwelling - the main switch may be used as the primary means of disconnect. 2. Two-family dwelling - same conditions apply as single-family residence. 3. Three (3) apartments or more - the circuit disconnect must be in the apartment or on the same floor. 4. Commercial or industrial - the branch circuit switch or breaker where readily accessible to the user or an approved thermostat is used as described below. 5. Thermostat used as disconnecting means - a thermostat or combination thermostat and switch will qualify as a disconnecting means provided it contains an identified "off" position, will not energize any conductors while in the "off" position, without being manually moved from said "off" position, and opens all ungrounded conductors simultaneously. (d) Portable electric heaters shall not be used in lieu of central heating systems. A central heating system shall mean "Equipment used to generate heat which is distributed by means of pipes, ducts or any other permanently connected source of heat used to furnish heat to an area". Exception: Portable electric heaters may be used during the time the central heating system is being repaired or replaced providing the portable electric heaters comply with Sec. 30.04(12) and the use of portable heaters will not exceed 72 hours excluding weekends and holidays. (5) Thermostat Requirements. Each space to be heated shall be controlled by one (1) or more thermostats and must meet the requirements of Sec. 30.04(4)(c)5. Maximum load of each thermostat shall be five (5) kilowatts. (6) Radiant Glass Heaters - Wall Type. (a) Heaters shall be installed on exterior walls where practical. Radiant type heaters shall not be installed on partitions which will cause such heaters to face an exposed outside wall, unless such installation is approved by the Heating, Ventilating, and Air Conditioning Inspector. (b) Radiant glass heaters shall not be installed in floors. (c) Radiant glass heaters shall not be installed on ceilings unless approved for ceiling mounting, in which case they shall comply with the requirements of prefabricated panels, where mounted tightly against the ceiling. (7) Convection, Resistance, and Fan-Forced Units. (a) Baseboard, wall, and standard fan-forced units shall be installed on exterior walls where practical. (b) Floor drop-in units shall be installed in close proximity to exterior walls. (c) Reverse flow fan-forced units shall be installed on interior partitions. (8) Electric Panel Heating Resistance - Cable Type. (a) Resistance cable shall not be installed in walls. (b) Cables may be installed in ceilings or poured masonry floors. Cables shall not be extended beyond the room in which they originate. Cables shall not be installed in closets, over cabinets, under walls or partitions, or over walls or partitions where embedded. This requirement shall not prohibit low temperature heat sources in closets to control relative humidity. (c) Cables shall be separated at least eight (8) inches from lighting fixtures, outlet and junction boxes, and two (2) inches from ventilating openings and other such openings in room surfaces. Sufficient area shall be provided to assure that no heating cables will be covered by surface-mounted lighting units. (d) Cables must not be plastered over until the Electrical Inspector has inspected the installation. (9) Electric Panel - Prefabricated Conductive Materials. (a) Prefabricated conductive panels shall not extend beyond the room in which they originate. (b) Panels shall not be installed on walls unless approved by the Electrical Inspector. (c) Panels shall be separated at least eight (8) inches from lighting fixtures, outlets, and junction boxes, and two (2) inches from ventilating openings and other such openings in room surfaces. Sufficient area shall be provided to assure that no heating panels will be covered by surface-mounted lighting areas. (10) Electric Central Heating Systems. Central heating systems of the forced warm air, gravity warm air, steam or hot water type, shall be installed in accordance with the applicable sections of the Heating, Ventilating and Air Conditioning Code. Resistance electric heating elements shall be controlled so that not more than five (5) kilowatts can be switched on simultaneously. (11) Electric Floor Furnaces. Self-contained heating units in the form of electric floor furnaces shall be installed in accordance with applicable sections of the Heating, Ventilating and Air Conditioning Code. Thermostatic control shall be provided within the heated space, except that no thermostatic control shall switch any combination of heating elements totaling more than five (5) kilowatts simultaneously. (12) Electrical Heaters, Portable. All portable electric heaters shall be provided with a three (3) wire cord and grounding type cap. The entire unit shall be in accordance with the Standards for Safety of Electrical Heating Appliances established by Underwriters' Laboratories, Incorporated, in their Bulletin No. UL 499, dated June, 1962, a copy of which is on file for inspection in the office of the Electrical Inspector. A thermostatic control shall be provided in each heated space, except that no individual thermostat shall switch any combination of heaters totaling more than five (5) kilowatts. (13) Other Permanently Placed Electric Heaters. Nothing in the regulations contained in Chapter 30 of the General Ordinances of the City of Madison shall prohibit the installation of other types of permanently placed electrical heat generating and emission units not presently covered herein when such units are approved by the Electrical Inspector and installed in a manner approved by such inspector, provided they meet the general provisions of Chapter 30 of the Madison General Ordinances of the City of Madison. No individual thermostatic control shall switch any combination of heaters totaling more than five (5) kilowatts.
(Cr. by Ord. 4830, 1-16-75)
Ask a question about Madison law
Corpus searches the Madison sections it holds and shows the ones that match, with their citations. Free, no sign-in.