30.17 - STOKER INSTALLATION.

The arrangement, equipment and manner of installation of all stokers hereafter installed for use in connection with heating plants, in or for buildings in the City of Madison, and the alterations hereafter of such stoker installations, shall conform to the following provisions. (1) Stoker Defined. The term "stoker" shall, for the purposes of this Code, be taken to mean a mechanical device for feeding solid fuel into the combustion chamber of a boiler or furnace used in connection with a heating plant, whether automatically or manually controlled. (2) Maximum Peak Load. The maximum peak load requirements of the plant must be determined in BTU per hour. The selection of the stoker should be based on the use of the lowest BTU value coal generally available and used at the point of consumption. (3) Heat Release. Heat release is the quantity of heat expressed in BTU per hour released in a combustion chamber for each cubic foot of furnace volume, computed with the following formula: Heat Release equals Pounds of coal burned per hour times BTU per pound of coal divided by Furnace Volume in cubic feet. (4) Combustion Volume. The combustion volume of the firing device shall be at least one (1) cubic foot for each sixty thousand (60,000) BTU of heat release for coal with twelve thousand (12,000) BTU. Use the following factors for coal of other than twelve thousand (12,000) BTU. BTU/Pound | Factor | BTU/Pound | Factor 9,000 | .75 | 11,500 | .96 9,500 | .79 | 12,500 | 1.04 10,000 | .83 | 13,000 | 1.08 10,500 | .87 | 13,500 | 1.12 11,000 | .92 | 14,000 | 1.17 (5) Setting Height. The following formula shall be used in determining setting height for stokers: For burning rates up to one hundred (100) pounds coal per hour—H equals 0.1125B plus 15.75 For burning rates from one hundred (100) to twelve hundred (1,200) pounds of coal per hour—H equals 0.03B plus 24. Where H equals minimum setting height, inches, measured from dead plates to crown sheet for steel boilers. For cast iron boilers, height may be 7/8 H. B equals Burning Rate coal per hour, pounds. (6) Ash Storage Space. Ash storage space (hearth area) shall be determined as follows: All stokers up to and including fifty (50) pounds per hour coal feed rate should have minimum depth of three (3) inches of flat hearth on all sides of the retort. (7) Grates for Stokers Over Two Hundred (200) Pounds. Per Hour Capacity. All stokers of two hundred (200) pounds per hour coal feed capacity and over should be installed with dead plates or dump grates. Under no circumstances shall they be installed with refractory hearths immediately adjacent to the tuyeres. (8) Clinker Removal Door Spacing. All stokers must be so installed that the maximum distance from the bottom of the lowest clinker removal door to the top of the hearth will not exceed eighteen (18) inches. (9) Pit Set Stoker. Where a stoker is pitted to a greater depth than eighteen (18) inches below the original floor of an installation, the pit shall be made large enough so that a minimum clearance from the furthermost extending part of the stoker on each side and the side wall of the pit will be eighteen (18) inches. (10) Hopper Clearance. In the case of a hopper model stoker, the minimum distance between the furthermost rear part of the stoker and the nearest wall or obstruction shall be twenty-four (24) inches. (11) Automatic Draft Control. On all stokers, some means of automatic draft control shall be installed. (12) Controls. (Refer to Control Section 30.25)

Ask a question about Madison law

Corpus searches the Madison sections it holds and shows the ones that match, with their citations. Free, no sign-in.