§ 7-1-8 — Fire Code and Life Safety Code amendments
Code of Ordinances of the City of Birmingham, Alabama (Supp. No. 3: codified through Ordinance No. 20-107, enacted June 29, 2020) · Birmingham Code of Ordinances § 7-1-8
Corpus is an independent public-information project, not the official City of Birmingham website. Stable reference: corpuslaw.us/code/89c0ecd7-1287-4f14-bfa4-7f4514d0a969
Sec. 7-1-8. - Fire Code and Life Safety Code amendments.
The provisions of the International Fire Code, 2015 Edition, published by the International Code Council and the NFPA 101-Life Safety Code, 2015 Edition, as described in this section and section 7-1-4 of this Code, published by the National Fire Protection Association, as amended herein shall apply to all buildings, structures, vehicles, premises, conditions, the construction, alteration, repair, equipment, use and occupancy, location, maintenance, removal and demolition, of every building or structure or any appurtenances connected or attached to such buildings or structures. INTERNATIONAL FIRE CODE AMENDMENTS Chapter 1 Is hereby deleted and is substituted with Article I, Part Two of this Code, and the following sections: F101 - GENERAL F101.1 Scope. This Code establishes regulations affecting or relating to structures processes, premises and safeguards regarding: 1. The hazard of fire and explosion arising from the storage, handling or use of structures, materials or devices; 2. Conditions hazardous to life, property or public welfare in the occupancy of structures or premises; 3. Fire hazards in the structure or on the premises from occupancy or operation; 4. Matters related to the construction, extension, repair, alteration or removal of fire suppression or alarm systems. 5. Conditions affecting the safety of fire fighters and emergency responders during emergency operations. F101.2 Intent. The purpose of this Code is to establish the minimum requirements consistent with nationally recognized good practice for providing a reasonable level of life safety and property protection from the hazards of fire, explosion or dangerous conditions in new and existing buildings, structures and premises and to provide safety to fire fighters and emergency responders during emergency operations. F101.3 Inspection authority. The fire code official is authorized to enter and examine any building, structure, marine vessel, vehicle or premises for the purpose of enforcing this Code. F101.4 Inspections. The fire code official is authorized to conduct such inspections as are deemed necessary to determine the extent of compliance with the provisions of this Code and to approve reports of inspection by approved agencies or individuals. All reports of such inspections shall be prepared and submitted in writing for review and approval. Inspection reports shall be certified by a responsible officer of such approved agency or by the responsible individual. The fire code official is authorized to engage such expert opinion as deemed necessary to report upon unusual, detailed or complex technical issues subject to the approval of the governing body. F102 - MAINTENANCE F102.1 Maintenance of safeguards. Whenever or wherever any device, equipment, system, condition, arrangement, level of protection, or any other feature is required for compliance with the provisions of this Code, or otherwise installed, such device, equipment, system, condition, arrangement, level of protection, or other feature shall thereafter be continuously maintained in accordance with this Code and applicable referenced standards. F102.2 Testing and operation. Equipment requiring periodic testing or operation to ensure maintenance shall be tested or operated as specified in this Code. F102.2.1 Test and inspection records. Required test and inspection records shall be available to the fire code official at all times or such records as the fire code official designates shall be filed with the fire code official. F102.2.2 Re-inspection and testing. Where any work or installation does not pass an initial test or inspection, the necessary corrections shall be made so as to achieve compliance with this Code. The work or installation shall then be resubmitted to the fire code official for inspection and testing. F102.3 Supervision. Maintenance and testing shall be under the supervision of a responsible person who shall ensure that such maintenance and testing is conducted at specified intervals in accordance with this Code. F102.4 Rendering equipment inoperable. Portable or fixed fire-extinguishing systems or devices and fire-warning systems shall not be rendered inoperative or inaccessible except as necessary during emergencies, maintenance, repairs, alterations, drills or prescribed testing. F102.5 Owner/occupant responsibility. Correction and abatement of violations of this Code shall be the responsibility of the owner. If an occupant creates, or allows to be created, hazardous conditions in violation of this Code, the occupant shall be held responsible for the abatement of such hazardous conditions. F102.6 Overcrowding. Overcrowding or admittance of any person beyond the approved capacity of a building or a portion thereof shall not be allowed. The fire code official, upon finding any overcrowding conditions or obstructions in aisles, passageways or other means of egress, or upon finding any condition which constitutes a life safety hazard, shall be authorized to cause the event to be stopped until such condition or obstruction is corrected. F103 - PERMITS A person, firm or corporation shall not maintain, store or handle materials, or conduct processes which produce conditions hazardous to life or property, or install equipment used in connection with such activities without first obtaining a permit from the Fire Official, this includes, but not limited to the utilization of fireworks, pyrotechnics, open flames, gas, flammable liquids or other products that produce open flames ("regulated materials"). A person, firm or corporation shall not install, alter, or remove a fire protection system in the City of Birmingham, or cause the same to be done, without first obtaining a permit from the Building or Fire Official. (See Article I, Part Two, Section 103, Construction Permits) F103.1 General F103.1.1 Fire Department Permits for demonstrations, special events and exhibits as described in section F104.2 and required by this Code shall be obtained from the Fire Code Official. Permit fees, if any, shall be paid prior to issuance of the permit. Issued permits shall be kept on the premises at all times and shall be readily available for inspection by the Fire Code Official. F103.1.2 Such permit shall not be a substitute for any license required by law. A fire code permit issued shall not be construed as authority to violate, cancel, alter, or set aside any of the provisions of this Code, nor shall such issuance of a life safety permit prevent the Fire Official from thereafter requiring a correction of violations of this Code. Every fire code permit issued shall become invalid unless the use authorized by such fire code permit is commenced within six months after its issuance, or if the use authorized by such life safety permit is suspended or abandoned for a period of six months after the time the use is commenced. F103.1.3 A permit shall not be transferable and any change in use or occupancy of a building or premises shall require a new permit. A permit shall continue until revoked or for such a period of time as designated at time of issuance. F103.1.4 A permit shall be obtained for all conditions described in this Code. F103.2 Conditions of Permits F103.2.1 The Fire Official shall act upon an application for permit without unreasonable delay and when issued such permit shall remain on the premises designated therein and shall at all times be subject to inspection. F103.2.2 Whenever the provision of this Code requires more than one permit for the same establishment or location, such permits may be combined into a single permit, but each provision shall be listed in the permit. F103.3 Compliance with Permit All permits issued under this Code shall require that the applicant, his agents and employees shall carry out the proposed activity in compliance with all the requirements of this Code and any other laws or regulations applicable thereto, whether specified in the permit or not in complete accordance with the approved plan and application. F103.4 Revocation of Permit The Fire Official may revoke a permit issued under this Code when it is found by inspection or otherwise that any one of the following conditions exists: 1. The permit is used for a location of establishment other than that for which it was issued. 2. The permit is used for a condition or activity other than that listed in the permit 3. Conditions and limitations set forth in the permit have been violated 4. There have been any false statements or misrepresentation as to a material fact in the application for the permit or plans submitted or a condition of the permit. 5. The permit is used by a different person or firm other than the name for which it was issued. F104 FEES F104.1 Schedule of Permit Fees A permit fee shall be paid for all permits as required in accordance with the schedules as established in this Code. F104.2 Permit Application and Fees Applications and fees for permits and inspections (excluding construction permits and construction inspections) required by Article VI of this Code shall be obtained from the Fire Prevention Division office of the Birmingham Fire and Rescue Service Department. The application must be accompanied by payment of the required compensation set forth herein prior to the issuance of a permit. Demonstrations, Special Events and Exhibits A permit is required for a person to organize or hold, assist in organizing or holding or to take part in or participate in any public demonstration, special event, exhibit, or other activity that utilizes or allows to be utilized any "regulated material" listed as follows: Class B or Class C explosives or fireworks, candles, open flames, gas, flammable liquids or other products that produce open flames. 1. A permit must be obtained a minimum of seven (7) days prior to the use of any regulated materials listed in this section. 2. Events utilizing "regulated material" shall require the on-site presence of fire inspectors. 3. All cooking booths, conventions, exhibits, demonstrations, or special events shall be inspected by the Fire Official to verify compliance with this Code. Fireworks, Pyrotechnics, Special Effects Permit (FW) A permit is required for all fireworks, pyrotechnics, open flames or special effects displays within the City of Birmingham. Fire Bonfire Permit (FB) No person shall kindle or maintain any bonfire or authorize any such fire to be kindled or maintained without a permit. Bonfires under this permit shall be an open fire for ceremonial purposes only. Fire Hydrant Use Permission (FH) Written permission (permit) to use a fire hydrant must be obtained from the Fire Official, which is a prerequisite to obtaining a permit from Birmingham Water Works. F104.3 Fees for Hydrant Flow Tests (FT) A permit fee shall be paid for a hydrant flow test requested by any person, firm or corporation. Chapter 5 Add the following subsections to Section 507 (pg. 71) of the 2015 IFC: F507.5.7 When the construction of a new subdivision, industrial or commercial complex, or other new construction makes the installation of public fire hydrants necessary to meet adequate fire protection requirements, as determined by the Fire Official, the city may assess the actual cost of such installations, including the first three years rental fees, to the individual or entity responsible for the new construction. The said installation fee shall be paid directly to the Water Authority governing the area of construction. The rental fees shall be paid directly to the City of Birmingham. Chapter 9 Replace subsection 901.4.5 (pg. 103) of the 2015 IFC with the following: F901.4.4 Appearance of equipment. Any device that has the physical appearance of life safety or fire protection equipment but that does not perform that life safety or fire protection function shall be prohibited. Exception: A property owner and/or occupant may request that a system be removed or vacated. This request could be based on a change in the use of a building that the installed system is no longer a requirement according to the City Adopted Codes such as: (1) a complete change of occupancy; (2) the fire hazard has been reduced; or (3) the life safety hazard has changed. This could also apply to older buildings where the system is dilapidated and never maintained in an operable condition. The Fire Official has the authority to approve or disapprove such vacations. Add the following subsections to Section 907: F907.3.1 Group A. A manual fire alarm system shall be installed in accordance with NFPA 72 in all existing Group A occupancies with an occupant load of 300 or more. Portions of Group E occupancies occupied for assembly purposes shall be provided with a fire alarm system as required for the Group E occupancy. Exception 1: Manual fire alarm boxes are not required where the building is equipped throughout with an automatic sprinkler system and the alarm notification appliances will activate upon sprinkler water flow. Exception 2: Group A occupancies used primarily for worship with an occupant load of 999 or less shall not be required to comply with this section. F907.3.2(a) System initiation in Group A occupancies with an occupant load of 1,000 or more. Activation of the fire alarm in existing Group A occupancies with an occupant load of 1,000 or more shall initiate a signal using an emergency voice/alarm communications system in accordance with NFPA 72. Exception: Where approved, the prerecorded announcement is allowed to be manually deactivated for a period of time, not to exceed 3 minutes, for the sole purpose of allowing a live voice announcement from an approved, constantly attended location. F907.3.2(b) Emergency power. Emergency voice/alarm communications systems shall be provided with an approved emergency power source. F907.3.3 A fire alarm system in accordance with NFPA 72 that complies with section F907.3.2(a) and (b) shall be installed in existing Group A occupancies used primarily for worship with an occupant load of 1000 or more. Chapter 34 Add the following subsection to Section 3406: F3406.5.1.6(a) Bulk storage and transfer facilities that have processing, blending, loading and transferring racks beneath a canopy shall be provided with an automatic fire protection system and/or systems compatible with the hazard. APPENDIX B is adopted in its entirety. APPENDIX C is adopted in its entirety. APPENDIX D is adopted in its entirety. APPENDIX F is adopted in its entirety. APPENDIX H is adopted in its entirety. APPENDIX I is adopted in its entirety. APPENDIX M is adopted in its entirety. AMENDMENTS TO NFPA 101 LIFE SAFETY CODE 2015 Chapter 24 Delete Chapter 24 One- and Two- Family Dwellings in its entirety without substitution. Chapter 2, Section 2.2 Delete NFPA 1 Uniform Fire Code
(Ord. No. 10-112, 8-24-2010; Ord. No. 15-164 , 11-30-2015; Ord. No. 16-19 , 2-16-2016)
Ask a question about Birmingham law
Corpus searches the Birmingham sections it holds and shows the ones that match, with their citations. Free, no sign-in.
