Sec. 12-72 - Specific construction and design standards.

In all SFHAs designated as A, AE, AH (with engineered or estimated BFE), the following provisions are required. (1) Residential and non-residential structures. Where BFE data is available, new construction, reconstruction, or repairs made to a repetitive loss structure, and substantial improvement of any structure or manufactured home shall have the lowest floor, including basement, and mechanical and electrical equipment servicing the structure elevated no lower than two (2) feet above the BFE. Should solid foundation perimeter walls be used to elevate a structure, openings sufficient to facilitate the unimpeded movements of flood waters shall be provided in accordance with standards of section 12-72(3). (2) Non-residential structures. New construction, reconstruction, or repairs made to a repetitive loss structure, and substantial improvement of any non-residential structure located in AE or AH zones, may be floodproofed (dry) in lieu of elevation. The structure, together with attendant mechanical, utility and sanitary facilities, must be designed to be water tight to at least two (2) feet above the BFE (herein after referred to as the design flood elevation), with walls substantially impermeable to the passage of water, and structural components having the capability of resisting hydrostatic and hydrodynamic loads and the effect of buoyancy. a. A registered professional engineer or architect, who is licensed to practice in the state, shall develop and/or review structural design, specifications, and plans for the construction, and shall certify that the design and methods of construction are in accordance with the standards in ASCE-24 (for dry floodproofing) or other compatible standards of practice for meeting the provisions above, and shall provide such certification to the official as set forth above and in section 12-57(9). b. A record of such certificates, which includes the specific elevation (in relation to mean sea level) to which such structures are floodproofed, shall be maintained with the official permitting records for the structure and kept in-perpetuity. c. Any non-residential functionally dependent structure (as defined in section 12-36) that cannot meet the standards stated in section 12-72(2)a. shall require a variance to be issued in accordance with section 12-60(e)3. and 12-60(c)l. d. Prior to the issuance of the certificate of occupancy, the following must be submitted for any non-residential structure that will be floodproofed. 1. Statement with the as-built floodproofing certificate; 2. An inspection and maintenance plan detailing the annual maintenance of floodproofed components ensuring that all components will operate properly under flood conditions. Components that must be inspected include at a minimum: • Mechanical equipment such as sump pumps and generators, • Flood shields and closures, • Walls and wall penetrations, and • Levees and berms (as applicable). 3. A Flood emergency operation plan detailing the procedures to be followed during a flooding event and must include information pertaining to how all components will operate properly under all conditions, including power failures. The design professional must prepare the plan, which shall include the following: • An established chain of command and responsibility with leadership responsibilities clearly defined for all aspects of the plan. • A procedure for notification of necessary parties when flooding threatens and flood warnings are issued. Personnel required to be at the building should have a planned and safe means of ingress/egress and should have no other emergency response duties during a flood event. Alternates should be assigned in the event that the primary persons responsible are unable to complete their assigned duties under the plan. • A list of specific duties assigned to ensure that all responsibilities are addressed expeditiously. The locations of materials necessary to properly install all floodproofing components must be included in the list. • An evacuation plan for all personnel or occupants; those without duties for the flood emergency as well as those with duties for implementing the plan. All possible ingress and egress routes must be identified. • A periodic training and exercise program to keep personnel and occupants aware of their duties and responsibilities. Training drills should be held at least once a year and should be coordinated with community officials. (3) Enclosures for elevated buildings. All new construction, reconstruction, or repairs made to a repetitive loss structure, and substantial improvements of existing structures (residential and non-residential) that include any fully enclosed area below the BFE, located below the lowest floor formed by the foundation and other exterior walls shall be designed so as to be an unfinished or flood resistant enclosure. The enclosure shall be designed to equalize hydrostatic flood forces on exterior walls by allowing for the automatic entry and exit of flood waters. a. Designs for complying with this requirement must either be certified by a professional engineer, who is licensed to practice in the state, or architect, who is registered to practice in the state, or meet the following minimum criteria: 1. Provide a minimum of two openings for each enclosed area having a total net area of not less than one square inch for every square foot of enclosed area subject to flooding (if a structure has more than one enclosed area below the BFE, each shall have openings on exterior walls); 2. Openings shall be in at least two walls of each enclosed area (includes areas separated by interior walls); 3. The bottom of all openings shall be no higher than one-foot above grade; and 4. Openings may be equipped with screens, louvers, valves and other coverings and devices provided they permit the automatic entry and exit of floodwaters in both directions without impeding or blocking flow and shall be accounted for in determination of the net open area; and 5. Openings meeting the requirements of section 12-72(3)a.1.-4. that are installed in doors are permitted. b. So as not to violate the "lowest floor" criteria of this article, the unfinished or flood resistant enclosure shall only be used for parking of vehicles, limited storage, or access to the elevated area. c. The interior portion of such enclosed area shall not be partitioned or finished into separate rooms. d. All interior walls, ceilings and floors below the BFE shall be unfinished and/or constructed of flood resistant materials. This practice is also referred to as "wet floodproofing". The definitions for "flood damage-resistant materials" and "wet floodproofing" are included in section 12-36. e. Mechanical, electrical or plumbing devices shall be installed not less than two (2) feet above the BFE. The interior portion of such enclosed area(s) shall be void of utilities except for essential lighting and power as required that are watertight or have otherwise been floodproofed. f. Property owners shall be required to execute a flood openings/venting affidavit acknowledging that all openings will be maintained as flood vents, and that the elimination or alteration of the openings in any way will violate the requirements for enclosures below the BFE. g. Property owners shall agree, certify, and declare to the conditions and restrictions set forth herein being placed on the affected property as a condition for granting a permit. A binding agreement, referred to as a non-conversion agreement, is required to be executed and recorded in the office of the judge of probate of the county in which the property is located. It shall obligate the owner to the following terms and conditions: 1. The enclosed area(s) shall remain fully compliant with all parts of section 12-72(3) of this article unless otherwise modified to be fully compliant with the applicable sections of this article in effect at the time of conversion. 2. A duly appointed representative of the city is authorized to enter the property for the purpose of inspecting the exterior and interior of the enclosed area to verify compliance with the agreement and permit in accordance to the provisions in section 12-57(16)a. 3. The city may take any appropriate legal action to correct any violation pertaining to such agreement and the subject permit. (4) Standards for manufactured homes and recreational vehicles where BFE data is available. a. All manufactured homes placed and substantially improved on: 1. Outside of a manufactured home park or subdivision on individual lots or parcels, 2. In a new or substantially improved manufactured home park or subdivision, 3. In an expansion to an existing manufactured home park or subdivision, or 4. in an existing manufactured home park or subdivision where a manufactured home has incurred "substantial damage" as the result of a flood, must be elevated on a permanent foundation such that the lowest floor, including basement, and mechanical and electrical equipment servicing the structure of the manufactured home is elevated two (2) feet or more above the BFE and be securely anchored to an adequately anchored foundation system to resist floatation, collapse, and lateral movement. b. Manufactured homes placed and substantially improved on sites in an existing manufactured home park or subdivision that are not subject to the provisions of section 12-72(4)a. may be elevated so that either: 1. The lowest floor of the manufactured home, including mechanical and electrical equipment servicing the structure, is elevated two (2) feet or more above the BFE, or 2. The manufactured home chassis and supporting equipment is supported by reinforced piers or other foundation elements of at least equivalent strength that are no less than 36 inches in height above the highest adjacent grade and be securely anchored to an adequately anchored foundation system to resist floatation, collapse, and lateral movement. 3. Concrete block piers (and other foundation systems) are to be designed in accordance with the Code of Federal Regulations Title 24, Part 3285 and with the specifications in FEMA P-85: Protecting Manufactured Homes from Floods and Other Hazards-A Multi-Hazard Foundation and Installation Guide. The §3285.306 design procedures for concrete block piers and FEMA P-85 (Table SP-1.1), specify that the maximum allowable pier height (measured from top of grade) for concrete piers to be five (5) feet. 4. The chassis and its supporting equipment are to be above the pier or other foundation. The areas below the chassis must be constructed with flood-resistant materials. All utilities and mechanical equipment must be elevated to a minimum of three (3) feet above the highest adjacent grade. Any utility and mechanical components that must be below the BFE must be made watertight to that same elevation to meet the standards in section 12-71(5). c. All recreational vehicles placed on sites must either: 1. Be on the site for fewer than 180 consecutive days, fully licensed and ready for highway use on its wheels or jacking system, attached to the site only by quick disconnect type utilities and security devices, and have no permanently attached structures or additions; or 2. Meet all the requirements for "new construction," including the anchoring and elevation requirements of section 12.72(3)a. and (3)b. (5) Standards for manufactured homes where no base flood elevation exists. a. Require that all manufactured homes to be placed within a Zone A area on the FIRM shall be installed using methods and practices which minimize flood damage. b. Manufactured homes must be elevated and anchored to resist flotation, collapse, or lateral movement. Methods of anchoring may include, but are not to be limited to, use of over-the-top or frame ties to ground anchors. c. The manufactured home chassis must be supported by reinforced piers or other foundation elements of at least equivalent strength such that the bottom of the chassis and its supporting equipment be no less than 36 inches and up to a maximum 60 inches (five feet) above the highest adjacent grade and be securely anchored to an adequately anchored foundation system. d. The areas below the chassis must be constructed with flood-resistant materials. All utilities and mechanical equipment must be elevated to a minimum of 3 feet above the highest adjacent grade. Any utility and mechanical components that must be below the BFE must be made watertight to that same elevation to meet the standards in section 12-71(5). (6) Designation of regulatory floodway. Require, until a regulatory floodway is designated, that no new construction, substantial improvements, or other development (including fill) shall be permitted within Zones A and AE on the city's FIRM, unless it is demonstrated that the cumulative effect of the proposed development, when combined with all other existing and anticipated development, will not increase the water surface elevation of the base flood more than one (1) foot at any point within the city. (7) Accessory and agricultural structures (also referred to as appurtenant structures) When an accessory structure meets the requirements outlined below, these structures may be wet-floodproofed and do not have to be elevated to two (2) feet above the BFE as required in section 12-72(1). Accessory structures include, but are not limited to, residential structures such as detached garages, storage sheds for garden tools or woodworking, gazebos, picnic pavilions, boathouses, small pole barns, and similar buildings. The following provisions apply: a. A permit shall be required prior to construction or installation of an accessory structures and any agricultural structures built below the DFE. b. The accessory structure must be designed with an unfinished interior and constructed with flood damage-resistant materials below the DFE as described in section 12-72(3). c. The accessory structure must be adequately anchored to prevent flotation, collapse, or lateral movement. d. The accessory structure must have adequate flood openings as described in section 12-72(3). e. The accessory structure shall be constructed and placed on the building site so as to offer the minimum resistance to the flow of floodwaters. f. Must comply with the requirements for development in floodways in accordance with section 12-76. g. Any mechanical and other utility equipment in or servicing the accessory structure must be elevated to or above the DFE or must be floodproofed in accordance with section 12-71. h. Storage of any hazardous or toxic materials below the DFE is prohibited. i. Permits for small accessory structures may be issued to provide wet floodproofing measures in accordance with the standards described in subsections (i) through (iv) below without requiring a variance. Before issuing permits for small accessory structures, the floodplain administrator must verify: 1. Use is limited to parking of vehicles or storage; 2. Size is less than or equal to a one-story, two-car garage for all A zones; 3. Structures are a minimal investment and have a low damage potential with respect to the structure and contents; 4. Structures will not be used for human habitation; and 5. Structures comply with the wet floodproofing requirements in section 12-72(3). j. Permits for accessory structures larger than the size allowed for in subsection 12-72(7)i. above, shall require a variance to be granted on a case-by-case basis in accordance with section 12-60(c)3. Variances shall not be granted for entire subdivisions for accessory structures. k. Permits for new construction of all agricultural structures shall require a variance to be granted on a case-by-case basis in accordance with section 12-60(c)4. l. Typically, when structures are substantially damaged by any cause or will be substantially improved, communities must require that the structures be brought into compliance with all requirements for new construction. In accordance with guidance in FEMA Publication 2140, agricultural structures that are substantially damaged by flooding and agricultural structures that are repetitive loss structures are permitted to be repaired or restored to pre-damage condition, provided the following are satisfied: 1. If substantially damaged, the substantial damage determination is based only on the cost to repair damage caused by flooding to pre-damage conditions. 2. The proposed repair or restoration does not change the size of the structure and does not significantly alter the nature of the building. With the exception of costs associated with wet floodproofing in accordance with section 12-72(3), proposals that include work beyond or in addition to that necessary to repair or restore the structure to pre-damage conditions must be regulated as substantial improvements as provided for in this article. 3. The repaired or restored structure will continue to be an agricultural structure, as defined in this article. 4. Owners are notified, in writing, that agricultural structures approved under this subsection: • Will not be eligible for disaster relief under any program administered by FEMA or any other federal agency. • Will have NFIP flood insurance policies rated based on the structure's risk. • May be denied NFIP flood insurance policies if repairs do not include the wet floodproofing requirements of section 12-72(3). 5. When owners elect to wet floodproof flood-damaged agricultural structures as part of repair or restoration to pre-damage condition, the structure shall comply with the requirements of section 12-72(3). 6. A variance shall be required to allow wet floodproofing in-lieu of elevation or dry-floodproofing in accordance with the definitions in section 12-36. m. Prohibit the storage of hazardous substances (as defined in section 12-36) in any residential accessory structure located in a SFHA. Limit the storage in nonresidential accessory structures to only fertilizers, petroleum products, and pesticides essential for landscaping purposes. Limit storage in agricultural structures to only fertilizers, petroleum products, and pesticides necessary for agricultural purposes. In both cases, storage shall be in strict compliance with the requirements of 12-72(9). (8) Underground and aboveground storage (liquid and gas) tanks. Tanks and tank inlets, fill openings, outlets, and vents that are located below the DFE shall be designed, constructed, installed, and anchored to resist all flood-related loads (flotation, collapse, or lateral movement resulting from hydrostatic and hydrodynamic forces) and any other loads, including the effects of buoyancy, during flooding up to and including the 100-year flood and without release of contents into floodwaters or infiltration of floodwaters into the tanks. a. A permit that includes floodplain development shall be required prior to construction or installation of any underground and aboveground tanks (including their foundation and support systems) located within a special flood hazard area. b. Loads on underground tanks and aboveground tanks exposed to flooding shall be determined assuming at least 1.3 times the potential buoyant and other flood forces acting on the empty tank. c. Tanks and associated piping shall be installed to resist local scour and erosion during the 100-year flood. d. Aboveground tanks located in Zone A/AB flood hazard areas shall be: 1. Elevated to or above the DFE on platforms or structural fill, 2. Elevated to or above the DFE where attached to structures and the foundation system supporting the structures shall be designed to accommodate any increased loads resulting from the attached tanks, 3. Permitted below the DFE where the tank and its foundation are designed to resist all flood-related loads including floating debris, or 4. Permitted below the DFE where the tank and its foundation are designed to resist flood loads and are located inside a barrier designed to protect the tank from floating debris. e. Aboveground tanks located in areas designated as Zone V/VE, Coastal A-Zones, and other high risk flood hazard areas (see ASCE 24-14) shall be elevated to or above the DFE on platforms that conform to the foundation requirements of ASCE 24-14, section 4.5. Aboveground tanks shall not be permitted to be located under elevated structures or attached to structures at elevations below one foot above the DFE in these areas. f. Underground tanks located in areas designated as Zone V/VE, Coastal A-Zones, and other high risk flood hazard areas (see ASCE 24-14) shall have the determination of flood-related loads take into consideration the eroded ground elevation. g. Tank inlets, fill openings, outlets, and vents shall be: 1. At or above the DFE or fitted with covers designed to prevent the inflow of floodwater or outflow of the contents of the tanks during conditions of the 100-year flood. 2. Anchored to prevent lateral movement resulting from hydrodynamic and hydrostatic loads, including the effects of buoyancy, during conditions of the 100-year flood. (9) Structures and sites for the storage or production of hazardous substances. Require that all outdoor storage sites, new construction, reconstruction or repairs made to a repetitive loss structure, and substantial improvements to be used for the production or storage of hazard substances (as defined in section 12-36) which are located in the special flood hazard area shall be built in accordance with all applicable standards in this article in addition to the following requirements: a. No structures containing hazardous substances shall be permitted for construction in a floodway; b. Residential structures shall have the area in which the hazard substances are to be stored elevated or dry floodproofed a minimum of two (2) feet above the BFE; c. Non-residential structures shall be permitted to be built below the BFE in accordance with section 12-72(2) such that the area where the hazard substance production or storage is located will be: 1. Elevated or designed and constructed to remain completely dry to at least two (2) feet above the BFE, and 2. Designed to prevent pollution from the storage containers, structure, or activity during the course of the base flood. d. Any solid, liquid, or gas storage containers of hazardous substances and any associated mechanical, electrical, and conveyance equipment shall be watertight and shall be properly anchored and protected from the hydrostatic and hydrodynamic forces of flood waters and debris carried by the base flood. (10) Construction of fences. New and replacement fences may be allowed in flood hazard areas if they do not act as a flow boundary and redirect the direction of flow, collect flood debris and cause blockages, cause localized increases in flood levels, or if damaged, become debris that may cause damage to other structures. (11) Structures elevated on fill. Fill for structures shall be designed to be stable under conditions of flooding, including rapid rise and rapid drawdown of floodwaters, prolonged inundation, and flood-related erosion and scour. The standards from ASCE 24 should be followed for any fill placed in flood hazard areas. All new construction for residential or non-residential structures may be constructed on permanent structural fill in accordance with the following: a. The lowest floor (including basement) of the structure or addition along with any appurtenant mechanical and electrical equipment and utilities shall be no lower than two (2) feet above the BFE. b. The nearest wall foundation of the structure shall have a minimum setback distance of 25 feet from the edge of the floodplain boundary. c. Fill used for structural support or protection shall consist of granular and earthen material that is free of vegetation and foreign or organic materials and suitable for its intended use. d. The fill shall be placed in layers no greater than one foot deep before compacting and should extend at least ten (10) feet beyond the foundation of the structure before sloping below the BFE, said slope being no greater than a 1:1.5 (vertical / horizontal) ratio unless a stability analysis is provided by a registered professional engineer. However, the ten-foot minimum may be waived if a structural engineer certifies an alternative method to protect the structure from damage due to erosion, scour, and other hydrodynamic forces. e. All new structures built on fill must be constructed on properly designed and compacted fill (ASTM D-698 or equivalent) that extends beyond the building walls before dropping below the BFE. f. The top of the fill shall be no lower than two foot above the BFE. g. The fill shall not adversely affect the flow or surface drainage from or onto any neighboring properties. h. Structural fill, including side slopes, shall be protected from scour and erosion under flood conditions up to and including the base flood discharge. When expected velocities during the occurrence of the base flood are greater than five feet per second, armoring with stone or rock protection shall be provided. When expected velocities during the base flood are five feet per second or less, protection shall be provided by covering them with vegetative ground cover. i. The design of the fill or the fill standard must be approved by a licensed professional engineer. j. The applicant shall submit a letter of map revision based on fill (LOMR-F) utilizing FEMA's MT-1 application forms to FEMA requesting a revision to the FIRM for the placement of fill. k. This standard is not applicable for placement of fill in a floodway; fill in a floodway is prohibited. (12) Incompatible uses prohibited in SFHAs. a. Lands lying within the 100-year floodplain shall not be used for: 1. Dumping of any material or substance including solid waste disposal sites (including manure), 2. On-site soil absorption sanitary sewage system site, 3. Petroleum or chemical holding tanks, 4. Construction of any wells used to obtain water for ultimate human consumption; or 5. Restricted confinement or permanent sheltering of animals. b. Lands lying within the 100-year floodplain shall not be used for the storage of materials that are buoyant, flammable, explosive, or injurious to human, animal, plant, fish, or other aquatic life.

(Ord. No. 24-2636, § 1, 3-18-24)

Ask a question about Hoover law

Corpus searches the Hoover sections it holds and shows the ones that match, with their citations. Free, no sign-in.