Sec. 12-75. - Construction and design standards for areas of shallow flooding (AO zones).
SFHAs established in section 12-41 may include designated "AO" shallow flooding areas. These areas have base flood depths of one to three feet (1'-3') above ground, with no clearly defined channel. The following provisions apply: (1) All new construction and substantial improvements of residential and nonresidential structures shall have the lowest floor, including basement and mechanical and electrical equipment servicing the structure, elevated above the highest adjacent grade at least as high as the depth number specified on the FIRM plus two (2) feet of freeboard. If no depth number is specified, the lowest floor, including basement and mechanical and electrical equipment servicing the structure, shall be elevated at least five (5) feet above the highest adjacent grade. Openings sufficient to facilitate the unimpeded movements of flood waters shall be provided in accordance with standards of section 12-72(3). The floodplain administrator shall certify the lowest floor elevation level and the record shall become a permanent part of the permit file. (2) New construction and the substantial improvement of a non-residential structure may be flood-proofed in lieu of elevation. The structure, together with attendant mechanical, utility and sanitary facilities, must be designed to be watertight to the specified flood level in section 12-75(1) or five (5) feet (if no depth number is specified), above the highest adjacent grade, with walls substantially impermeable to the passage of water, and structural components having the capability of resisting hydrostatic and hydrodynamic loads and the effect of buoyancy. A registered professional engineer, who is licensed to practice in the state, or architect, who is registered in the state, shall certify that the design and methods of construction are in accordance with accepted standards of practice for meeting the provisions above, and shall provide such certification to the official as set forth above and as required in sections 12-59(1) and 12-59(2). (3) Drainage paths shall be provided to guide floodwater around and away from any proposed structure.
(Ord. No. 24-2636, § 1, 3-18-24)
Ask a question about Hoover law
Corpus searches the Hoover sections it holds and shows the ones that match, with their citations. Free, no sign-in.