§ 12-73 — Building and design standards for streams without established base flood elevations (approximate a-zones)
Code of Ordinances of the City of Hoover, Alabama (Supplement 23, published 2025-05-19 (Municode online 2026-03-30).) · Hoover Municipal Code § 12-73
Corpus is an independent public-information project, not the official City of Hoover website. Stable reference: corpuslaw.us/code/94633bd2-048d-430a-8cc7-ba45645bfb86
Sec. 12-73. - Building and design standards for streams without established base flood elevations (approximate a-zones).
Located within the SFHAs established in section 12-41, where streams exist but no base flood data have been provided (Approximate A-Zones), the following provisions apply. (1) BFE data shall be provided for new subdivision proposals and all other proposed development, including manufactured home parks and subdivisions, greater than fifty (50) lots or five (5) acres, whichever is the lesser. (2) When BFE data or floodway data have not been provided in accordance with section 12-41 then the floodplain administrator shall obtain, review, and reasonably utilize any scientific or historic BFE and floodway data available from a federal, state, or other source, in order to administer the provisions of division 3. Only if data is not available from these sources, then section 12-73(5) and section 12-73(6) shall apply. (3) No encroachments, including structures or fill material, shall be located within an area equal to the width of the stream or 25 feet, whichever is greater, measured from the top of the stream bank, unless certification by a registered professional engineer is provided demonstrating that such encroachment shall not result in any increase in flood levels during the occurrence of the base flood discharge. (4) All development in Zone A must meet the requirements of section 12-71 and section 12.72(1),(2),(3),(5),(6),(7),(8),(9),(10),(11), and (12). (5) In SFHAs without BFE data, new construction and substantial improvements of existing structures shall have the lowest floor (for the lowest enclosed area; including basement) elevated no less than five (5) feet above the highest adjacent grade. (6) In the absence of a BFE, a manufactured home must also meet the elevation requirements of section 12-72(4)(b)2—4. in that the structure cannot be elevated above a maximum of 60 inches (5 feet) and all utilities and mechanical equipment must be elevated a minimum of three (3) feet above the highest adjacent grade. (7) Enclosures for elevated buildings in Zone A areas shall comply with the standards of section 12-72(3)a. The floodplain administrator shall certify the lowest floor elevation level and the record shall become a permanent part of the permit file.
(Ord. No. 24-2636, § 1, 3-18-24)
Ask a question about Hoover law
Corpus searches the Hoover sections it holds and shows the ones that match, with their citations. Free, no sign-in.
