§ 17-25 — Construction standards for areas where the city has identified a flood hazard, but FEMA has not identified a special flood hazard area (or elevation)
Code of the City of Mobile, Alabama (Supp. No. 67: codified through Ordinance No. 36-017-2026, adopted March 1, 2026) · Mobile City Code § 17-25
Corpus is an independent public-information project, not the official City of Mobile website. Stable reference: corpuslaw.us/code/e32e3426-5aad-49cc-8f21-281b50fe926d
Sec. 17-25. - Construction standards for areas where the city has identified a flood hazard, but FEMA has not identified a special flood hazard area (or elevation)
When FEMA has not defined the special flood hazard areas in an area within the city, has not provided water surface elevation data, and has not provided sufficient data to identify the floodway or coastal high hazard area, but the city has through historical data identified the presence of special flood hazards, the city shall: (1) Require permits for all proposed construction or other development in the city, including the placement of manufactured homes, so that it may determine whether such construction or other development is proposed within flood-prone areas; (2) Require copies of all necessary permits governmental agencies from which approval is required by federal or state law, including section 404 of the Federal Water Pollution Control Act Amendments of 1972, 33 U.S.C. 1334; maintain such permits on file. (3) Review all permit applications to determine whether proposed building sites will be reasonably safe from flooding. All new construction and substantial improvements shall: a. Be designed (or modified) and adequately anchored to prevent flotation, collapse, and lateral movement of the structure resulting from hydrodynamic and hydrostatic loads, including the effects of buoyancy, b. Be constructed with materials resistant to flood damage, c. Be constructed by methods and practices that minimize flood damages, and d. All heating and air conditioning equipment and components, all electrical, ventilation, plumbing, and other service facilities shall be designed and/or located so as to prevent water from entering or accumulating within the components during conditions of flooding. (4) New construction and substantial improvements of existing structures shall be constructed by methods and practices that minimize flood damage: a. All subdivision proposals shall be consistent with the need to minimize flood damage; b. All subdivision proposals shall have public utilities and facilities, such as sewer, gas, electrical, and water systems located and constructed to minimize flood damage, c. All subdivision proposals shall have adequate drainage provided to reduce exposure to flood hazards, and d. Drainage paths shall be provided to guide floodwater around and away from any proposed structure. (5) New and replacement water supply systems to be designed to minimize or eliminate infiltration of flood waters into the systems. (6) New and replacement sanitary sewage systems shall be designed to minimize or eliminate infiltration of flood waters into the systems and discharges from the systems into flood waters and (7) On-site waste disposal systems to be located to avoid impairment to them or contamination from them during flooding. (8) Construction must comply with all applicable requirements in the city's latest adopted building code and in all ordinances. (9) New construction and substantial improvements of existing structures shall be anchored to prevent flotation, collapse and lateral movement of the structure. (10) New construction and substantial improvements of existing structures shall be constructed with materials and utility equipment resistant to flood damage. (11) Manufactured homes shall be anchored to prevent flotation, collapse, and lateral movement. Methods of anchoring may include, but are not limited to, use of over-the-top or frame ties to ground anchors. This standard shall be in addition to and consistent with applicable state requirements for resisting wind forces. (12) Any alteration, repair, reconstruction or improvement to a structure which is not compliant with the provisions of this chapter, shall be undertaken only if the non-conformity is not furthered, extended or replaced. (13) Proposed new construction and substantial improvements that are partially located in an area of special flood hazard shall have the entire structure meet the standards for new construction. (14) Proposed new construction and substantial improvements that are located in multiple flood hazard risk zones or in a flood hazard risk zone with multiple base flood elevations shall have the entire structure meet the standards for the most hazardous flood hazard risk zone and the highest base flood elevation.
(Ord. No. 17-013-2020, 5-19-20)
Ask a question about Mobile law
Corpus searches the Mobile sections it holds and shows the ones that match, with their citations. Free, no sign-in.