§ 17-29 — Construction standards for coastal high hazard areas (V zones)
Code of the City of Mobile, Alabama (Supp. No. 67: codified through Ordinance No. 36-017-2026, adopted March 1, 2026) · Mobile City Code § 17-29
Corpus is an independent public-information project, not the official City of Mobile website. Stable reference: corpuslaw.us/code/1b3de345-3a6a-4050-8e57-128122163738
Sec. 17-29. - Construction standards for coastal high hazard areas (V zones).
When FEMA has provided a notice of final base flood elevations within zones A1-30 and/or AE on the city's FIRM and, if appropriate, has designated AH zones, AO zones, A99 zones, A and X-shaded zones on the city's FIRM, and has identified on the city's FIRM coastal high hazard areas by designating zones V1-30, VE, V, and/or coastal AE, the city shall: (1) Meet the requirements of paragraphs (1) through (15) of section 17-27. (2) Within zones V1-30, VE, and V on the city's FIRM: a. Obtain the elevation (in relation to mean sea level) of the bottom of the lowest structural member of the lowest floor (excluding pilings and columns) of all new and substantially improved structures, in VE zones and coastal AE zones and whether or not such structures contain a basement; and b. The director of the permitting department shall maintain a record of all such information. (3) All new construction within zones V1-30, VE, V, and/or coastal AE zones on the city's FIRM shall be located landward of the reach of mean high tide. (4) All new construction and substantial improvements in zones V1-30 and VE and coastal AE zones, and also zone V if base flood elevation data is available, on the city's FIRM, shall be elevated on piles, columns, or shear walls parallel to the flow of water so that: a. The bottom of the lowest supporting horizontal structural member (excluding the pilings or columns) is located to no lower than the base flood elevation level. b. All pile and column foundation and the structures attached thereto shall be anchored to resist flotation, collapse and lateral movement due to the effects of wind and water loads acting simultaneously on ALL building components, both (non-structural and structural). c. Water loading values used shall equal or exceed those of the base flood. d. Wind loading values used shall be in accordance with the latest adopted building code by the city. e. All new construction and substantial improvements of existing structures shall be securely anchored on pilings, columns, or shear walls. f. A registered professional engineer or architect shall certify that the design, specifications and plans for construction are in full compliance with the provisions contained in subsection 17-29(4)a through f. (5) For all new construction and substantial improvements within zones V1-30, VE, and V and coastal AE zones on the city's FIRM, the space below the lowest horizontal-supporting member must remain free of obstruction. As an alternative, the space may be constructed with non-supporting breakaway walls, open wood or vinyl lattice-work, or insect screening which must be designed to collapse under wind and water loads without causing collapse, displacement, or other structural damage to the elevated portion of the building or supporting foundation system. The following design specifications are required: a. No solid walls shall be allowed. b. Material shall consist of lattice or mesh screening only. c. If aesthetic lattice work, breakaway walls, or screening is utilized, any enclosed space shall not be used for human habitation but, shall be designed to be used only for parking of vehicles, building access, or limited storage of maintenance equipment used in connection with the premises. d. For the purposes of this section, a breakaway wall shall have a design safe loading resistance of not less than ten (10) and no more than twenty (20) pounds per square foot. Breakaway wall enclosures shall not exceed two hundred ninety-nine (299) square feet. Use of breakaway walls which exceed a design safe loading resistance of twenty (20) pounds per square foot (either by design or when so required by local codes) may be permitted only if a registered professional engineer or architect certifies that the designs proposed meet the following conditions: i. Breakaway wall collapse shall result from a water load less than that which would occur during the base flood; and, ii. The elevated portion of the building and supporting foundation system shall not be subject to collapse, displacement, or other structural damage due to the combined effects of wind and water loads acting simultaneously on all building components (structural and non-structural). iii. Water loading values used shall be those associated with the base flood. iv. Wind loading values used shall be those required by applicable state or latest adopted building code. v. Enclosures below elevated buildings shall be useable solely for parking of vehicles, building access, or storage. Such space will not be used for human habitation and not finished or partitioned into separate rooms. e. Prior to construction, plans for any structure using lattice, breakaway walls, or decorative screening must be submitted to the permitting department for approval. f. Any alteration, repair, reconstruction or improvement to any structure shall not enclose the space below the lowest floor except with latticework, breakaway walls, or decorative screening, as provided in this section. (6) Under the buildings or structures, no fill may be used except for minor site grading for drainage purposes. Nonstructural fill may be used on coastal building sites for minor landscaping and site grading for drainage purposes to the extent that the fill does not interfere with the free passage of floodwaters and debris underneath the building or cause changes in flow direction during coastal storms. Changes to site grades, other than those prescribed, must be avoided as they can cause additional damage to buildings on the site or to adjacent buildings. Fill placed in coastal zones should be similar (compatible) to the natural soils in the area and not contain large rocks or debris, organic materials, or clay. Minor site grading is to be limited to the addition of one to two feet of coastal zone compatible soils. If additional fill (greater than two feet) or non-compatible soils are to be added to the site, certification by a professional engineer or architect shall be submitted along with design calculations demonstrating that no adverse impacts will result to the building. (For guidance, see FEMA Technical Bulletin #5 "Free of Obstruction Requirements"). The city engineer shall approve design plans for landscaping/aesthetic fill only after the applicant has provided an analysis by an engineer, architect and/or soil scientist, which demonstrates that the following factors have been fully considered: a. Particle composition of fill material does not have a tendency for excessive natural compaction; b. Volume and distribution of fill will not cause wave deflection to adjacent properties, and c. Slope of fill will not cause wave run-up or ramping; (7) Prohibit man-made alteration of sand dunes and mangrove stands within zones V1-30, VE, and V on the city's FIRM which would increase potential flood damage. (8) Prohibit the placement of manufactured homes (mobile homes), except in an existing manufactured homes park or subdivision V1-30, V, and VE on the city's FIRM. A replacement manufactured home may be placed on a lot in an existing manufactured home park or subdivision provided the anchoring and elevation standards of subsections 17-27(7)a and c are met. All standards from subsections 17-27(6) and (7) must also be met. (9) Permit recreational vehicles in VE zones and coastal AE zones if they meet all of the requirements of subsection 17-27(8). In addition, if they are not compliant with subsection 17-27(8)a, then they must also meet all requirements in subsections 17-29(1) to (8).
(Ord. No. 17-013-2020, 5-19-20)
Ask a question about Mobile law
Corpus searches the Mobile sections it holds and shows the ones that match, with their citations. Free, no sign-in.
