For AI agents: read the machine-readable documentation index at /llms.txt or the single-file full reference at /llms-full.txt.

§ 17-27 — Construction standards for areas without established base flood elevation and floodways (A1-30 zones, AE zones, AH zones, AO zones, and X-shaded zones)

Code of the City of Mobile, Alabama (Supp. No. 67: codified through Ordinance No. 36-017-2026, adopted March 1, 2026) · Mobile City Code § 17-27

Corpus is an independent public-information project, not the official City of Mobile website. Stable reference: corpuslaw.us/code/7bd7ef6f-543e-476d-9fd5-5a47b2fda7cf

Sec. 17-27. - Construction standards for areas without established base flood elevation and floodways (A1-30 zones, AE zones, AH zones, AO zones, and X-shaded zones).

When the FEMA has provided a notice of final flood elevations for one (1) or more special flood hazard areas on the city's FIRM and, if appropriate, has designated other special flood hazard areas without base flood elevations on the city's FIRM, but has not identified a regulatory floodway or coastal high hazard area, the city shall: (1) Require the standards of section 17-25 to all A1-30 zones, AE zones, A zones, AH zones, AO zones, and X-shaded zones on the city's FIRM; (2) Residential and non-residential structures—Where base flood elevation data is available, new construction and substantial improvement of any structure or manufactured home shall have the lowest floor including basement, elevated to the base flood elevation unless the city is granted an exception by the administrator for the allowance of basements in accordance with CFR title 44, volume 1, sec. 60.6(b) or (c). Should solid foundation perimeter walls be used to elevate a structure, openings sufficient to facilitate the unimpeded movements of flood waters shall be provided in accordance with standards of subsection 17-27(4). (3) Non-residential structures—New construction and substantial improvements of non-residential structures located in zones A1-30, AE and AH zones, and X-shaded zones on the city's FIRM, may be floodproofed in lieu of elevation. The structure, together with attendant utility and sanitary facilities, must be designed to be watertight above the base flood elevation, with walls substantially impermeable to the passage of water, and structural components having the capability of resisting hydrostatic and hydrodynamic loads and effects of buoyancy. (4) Provide that where a non-residential structure is intended to be made watertight below the base flood level: a. A registered professional engineer or architect shall certify that the design and methods of construction are in accordance with accepted standards of practice for meeting the provisions above, and shall provide official as set forth above and in subsection 17-5(4). b. A record of such certificates which includes the specific elevation (in relation to mean sea level) to which such structures are flood-proofed shall be maintained with the director of the permitting department; c. Dry flood proofing is allowed only where flood velocities are less than or equal to five feet per second. A registered professional engineer or architect shall certify that the standards of this subsection are satisfied. A flood emergency operation plan and an inspection and maintenance plan must be provided by the design professional for the building. Such certification shall be provided to the city engineer. (5) Enclosures for elevated buildings—All new construction and substantial improvements of existing structures, that include ANY fully enclosed areas below the base flood elevation, located between the lowest floor formed by the foundation and the other exterior walls shall be designed so as to be an unfinished or flood resistant enclosure. The enclosure shall be designed to automatically equalize hydrostatic flood forces on exterior walls by allowing for the entry and exit of floodwaters. a. Designs for meeting this requirement must either be certified by a registered professional engineer or architect or meet or exceed the following minimum criteria: 1. Provide a minimum of two (2) openings having a total net area of not less than one (1) square inch for every square foot of enclosed area subject to flooding (if a structure has more than one (1) enclosed area below the base flood elevation, each shall have openings on exterior walls); 2. The bottom of all openings shall be no higher than one (1) foot above grade; and 3. Openings may be equipped with screens, louvers, valves, coverings or devices provided that they permit the automatic flow of floodwater in both directions. b. So as not to violate the "lowest floor" criteria of this chapter, the unfinished or flood resistant enclosure shall only be used for parking of vehicles, limited storage of maintenance equipment used in connection with the premises, or entry to the elevated area. c. The interior portion of such enclosed area shall not be partitioned or finished into separate rooms. All interior walls, ceilings and floors below the base flood elevation shall be unfinished and/or constructed of flood resistant materials. d. Mechanical, electrical or plumbing devices shall not be installed below the base flood elevation. The interior portion of such enclosed area(s) shall be void of utilities except for essential lighting and power as required. (6) Standards for manufactured homes and recreational vehicles—Within zones A1-30, AH, AE, and X-shaded on the city's FIRM: a. All manufactured homes placed or substantially improved on: 1. Individual lots or parcels outside of a manufactured home park or subdivision, 2. In new or substantially improved manufactured home parks or subdivisions, 3. In expansions to existing manufactured home park or subdivisions, or 4. On a site in an existing manufactured home park or subdivision where a manufactured home has incurred "substantial damage" as the result of a flood, must have the lowest floor including basement elevated no lower than the base flood elevation and be securely anchored to an adequately anchored foundation system to resist floatation collapse and lateral movement. (7) Manufactured homes placed and substantially improved in an existing manufactured home park or subdivision within zones A1-30, AH, AE, and X-shaded on the city's FIRM that are not subject to the provisions of paragraph (6) of this section be elevated so that either: a. The lowest floor of the manufactured home is no lower than the level of the base flood elevation, or b. Where no base flood elevation exists, the manufactured home chassis and supporting equipment is supported by reinforced piers or other foundation elements of at least equivalent strength that are no less than thirty-six (36) inches in height above grade and is elevated to a maximum of sixty (60) inches (five (5) feet) above grade and must also meet the standards of subsection 17-26(11). c. All manufactured homes must be securely anchored to an adequately anchored foundation system to resist floatation, collapse, and lateral movement. (8) All recreational vehicles placed on sites within zones A1-30, AH, AE, and X-shaded on the city's FIRM must either: a. Be on the site for fewer than one hundred eighty (180) consecutive days; b. Be fully licensed and ready for highway use; or c. Meet the permit requirements of paragraph (1) of section 17-26 and the elevation and anchoring requirements for "manufactured homes" in paragraph (6) of this section. A recreational vehicle is ready for highway use if it is licensed, on its wheels or jacking system, is attached to the site only by quick disconnect type utilities and security devices, and has no permanently attached additions; or d. The recreational vehicle must meet all the requirements for "new construction," including the anchoring and elevation requirements of subsection 17-27(5)a and b. (9) Within any AO or X-shaded zone on the city's FIRM all new construction and substantial improvements of residential and non-residential structures shall have the lowest floor (including basement) elevated above the highest adjacent grade at least as high as the depth number specified in feet on the city's FIRM. If no depth number is specified, the lowest floor, including basement, shall be elevated at least two (2) feet above the highest adjacent grade. Openings sufficient to facilitate the unimpeded movements of flood waters shall be provided in accordance with standards of subsection 17-27(5), "Enclosures for elevated buildings." The city engineer shall certify the lowest floor elevation level and the record shall become a permanent part of the permit file. (10) Within any AO or X-shaded zone on the city's FIRM all new construction and substantial improvements of nonresidential structures may be flood-proofed in lieu of elevation. a. Have the lowest floor (including basement) elevated above the highest adjacent grade at least as high as the depth number specified in feet on the community's FIRM (at least two (2) feet if no depth number is specified), or b. The structure, together with attendant utility and sanitary facilities must be completely flood-proofed to that level to meet the flood-proofing standard specified in paragraph (2) of this section; or c. Together with attendant utility and sanitary facilities, must be designed to be water tight to the specified flood level as specified in subsection 17-27(5) or two (2) feet (if no depth number is specified), above highest adjacent grade, with walls substantially impermeable to the passage of water, and structural components having the capability of resisting hydrostatic and hydrodynamic loads and the effect of buoyancy. A registered professional engineer or architect shall certify that the design and methods of construction are in accordance with accepted standards of practice for meeting the provisions above, and shall provide such certification to the official as set forth above and as required in subsection 17-6(d)(2) and 17-22. (11) Require within any A99 or X-shaded zones on the city's FIRM the standards of subsections 17-25(1) through (4)a and subsections 17-26(5) through (8) of this chapter. (12) Require, until a regulatory floodway is designated, that no new construction, substantial improvements, or other development (including fill) shall be permitted within zones A1-30, AE, or X-shaded on the city's FIRM, unless it has been demonstrated that the cumulative effect of the proposed development, when combined with all other existing and anticipated development, through hydrologic and hydraulic analyses performed in accordance with standard engineering practice that the proposed encroachment will not increase the base flood discharge at any point in the city. (13) Require within zones AH, AO, and X-shaded adequate drainage paths around structures on slopes, to guide floodwaters around and away from proposed structures. (14) Notwithstanding any other provisions of this chapter, the city may approve certain development in zones A1-30, AE, AH, and X-shaded on the city's FIRM which do not increase the water surface elevation of the base flood, provided that the city first applies for a conditional FIRM revision, fulfills the requirements for such a revision as established under the provisions of the Code of Federal Regulations, title 44, volume 1, sec. 65.12, and receives the approval of FEMA. (15) Accessory structures (also referred to as appurtenant structures)—This provision generally applies to new and substantially improved accessory structures. When an accessory structure complies with all other provisions of this chapter (including floodway encroachment), represents a minimal investment (less than $1,000.00), and meets the requirements outlined below, these structures may be wet-floodproofed and do not have to be elevated or dry floodproofed. Accessory structures include, but are not limited to, residential structures such as detached garages, storage sheds for garden tools or woodworking, gazebos, picnic pavilions, boathouses, small pole barns, and similar buildings. The following provisions apply to accessory structures built below the base flood elevation: a. No accessory buildings in special flood hazard areas designated VE or V-zone or "coastal AE" are allowed. b. A permit shall be required prior to construction or installation. c. Must be low value (less than $1,000.00) and not be used for human habitation. d. Use must be restricted to parking of personal vehicles or limited storage (low-cost items that cannot be conveniently stored in the principal structure). e. Must be designed with an unfinished interior and constructed with flood damage-resistant materials below the BFE. f. Must be adequately anchored to prevent flotation, collapse, or lateral movement. g. Must have adequate flood openings as described in subsection 17-25(3)d and be designed to otherwise have low flood damage potential. h. Shall be constructed and placed on the building site so as to offer the minimum resistance to the flow of floodwaters. i. Any mechanical and other utility equipment in the structure must be elevated to or above the BFE or must be floodproofed. j. Under limited circumstances communities may issue variances to permit construction of wet-floodproofed accessory structures. Communities should not grant variances to entire subdivisions for accessory structures, especially detached garages. Variances should only be reviewed and issued on an individual or case-by-case basis and be based on the unique characteristics of the site.

(Ord. No. 17-013-2020, 5-19-20)

Ask a question about Mobile law

Corpus searches the Mobile sections it holds and shows the ones that match, with their citations. Free, no sign-in.