§ 166.03 — Plat Requirements
Code of Ordinances of the City of Fayetteville, Arkansas (Codified through Ordinance No. 7010, enacted June 16, 2026 (Supp. No. 42)) · Fayetteville Code of Ordinances § 166.03
Corpus is an independent public-information project, not the official City of Fayetteville website. Stable reference: corpuslaw.us/code/6b8631dc-2f45-447c-88a3-fffde688875a
166.03 - Plat Requirements
(A) Original Plan Drawings. Plans shall be drawn in a legible manner, at a scale which best suits the size of the property being developed or platted. All plans shall be drawn at a standard engineering scale, and submitted in paper and/or digital form, as listed on the application. (B) Plat Information. The following information shall be submitted to the Planning Division and/or Planning Commission for review and approval: (1) General. Preliminary Plat | Final Plat | Concurrent Plat | Property Line Adj. | Lot Split | Large-Scale, SIP, PZD | Concept Plat Name, address, zoning and property lines of all property owners adjacent to the exterior boundaries of the project. | X | X | X | X | X | X | X Name, address, telephone numbers of owner(s), developer(s) and project representatives | X | X | X | X | X | X | X North arrow, scale (graphic and written), date of preparation zoning classification, and proposed use. | X | X | X | X | X | X | X Title block located in the lower right hand corner indicating the name and type of project, scale, firm or individual preparing drawing, date and revisions. | X | X | X | X | X | X | X Provide a complete and accurate legend | X | X | X | X | X | X | X A vicinity map of the project with a radius of 1.5 miles from the project. This map shall include any Master Street Plan streets as well as the 100-year flood plain boundary. | X | X | X | X | X | X | X The location of all existing structures | X | X | X | X | X | X | X Site coverage note indicating the percentage of site that is covered by impervious surface. | X (2) Legal Description. Preliminary Plat | Final Plat | Concurrent Plat | Property Line Adj. | Lot Split | Large-Scale, SIP, PZD | Concept Plat Written legal descriptions including area in square feet or acres that read clockwise (Note: If the project is contained in more than one tract, the legal for each individual tract and a total tract description must be provided.) | X | X | X | X | X | X Boundary survey of the property shown on the plat. The surveyor shall seal, sign and date the survey. Each survey plat shall have 2 points described in State Plane Coordinates, Arkansas, North, North American Datum, 1983 (NAD 83) | X | X | X | X | X | X | X Provide a benchmark, clearly defined with an accuracy of 1/100 feet. This benchmark must be tied to USC & GS Datum. Benchmarks include but are not limited to the following: fire hydrant, manhole, etc. | X | X | X | X Point-of-beginning from a permanent well-defined reference point. This P.O.B. shall be clearly labeled on the drawing. | X | X | X | X | X | X Curve data for any street which forms a project boundary. | X | X | X | X | X | X (3) Floodplain/Floodways/Wetlands. Preliminary Plat | Final Plat | Concurrent Plat | Property Line Adj. | Lot Split | Large-Scale, SIP, PZD | Concept Plat Show 100-yr floodplain and/or floodway and based flood elevations. Reference the FIRM panel number and effective date. | X | X | X | X | X | X | X Note regarding wetlands, if applicable. Note if Army Corps of Engineers determination is in progress. | X | X | X (4) Topographic Information. Preliminary Plat | Final Plat | Concurrent Plat | Property Line Adj. | Lot Split | Large-Scale, SIP, PZD | Concept Plat Existing and proposed topographic information with source of the information noted. Show: a. 2-foot contour intervals for ground slope between level and 10%. b. 5-foot contour interval for ground slope exceeding 10%. | X | X Spot elevations at grade breaks along existing road centerlines, gutter lines and top of curbs or edge of pavement. | X | X Contours of adjacent land within 100 feet of the project shall also be shown. | X | X (5) Tree Protection/Landscaping. Preliminary Plat | Final Plat | Concurrent Plat | Property Line Adj. | Lot Split | Large-Scale, SIP, PZD | Concept Plat Delineate trees to be retained on-site and the measures to be implemented for their protection. | X | X | X | X | X Clearly depict the limits of soil disturbance to include all areas to be graded both on- and off-site. | X | X | X | X Show proposed location of all utilities. | X | X | X | X Landscape proposals for parking lots and/or tree replacement requirements shall include proposed plant species and size. Existing and proposed utility lines shall be shown on the plan. State the method for irrigating the plant material on the plan. When an ordinance requires shrubs or other screening material, show the layout of planting beds. | X | X | X | X (6) Utilities—Existing. Preliminary Plat | Final Plat | Concurrent Plat | Property Line Adj. | Lot Split | Large-Scale, SIP, PZD | Concept Plat Show on the drawing all known on-site and off-site existing utilities and easements (dimensioned) and provide the structure's locations, types, and condition and note them as "existing" on the plat. | X | X | X | X | X | X | X Existing easements shall show the name of the easement holder, purpose of the easement, and the book and page number for the easement. If an easement is blanket or indeterminate in nature, a note to this effect shall be placed on the plat or plan. | X | X | X | X | X | X (7) Utilities—Proposed. Preliminary Plat | Final Plat | Concurrent Plat | Property Line Adj. | Lot Split | Large-Scale, SIP, PZD | Concept Plat Show all storm sewer structures, sanitary sewer structures and drainage structures: a. Provide structure locations and types b. Provide pipe types and sizes | X | X | X | X Sanitary sewer systems: a. Provide pipe locations, sizes, and types b. Manhole locations of rim and invert elevations. | X | X | X | X | X | X Note the occurrence of any previous water, sewer, or storm sewer overflow problems on-site or in the proximity of the site. | X | X | X If a septic system is to be utilized, provide a table of acreage and percolation rates. | X | X | X Water systems, on or near the site: a. Provide pipe locations, types, and sizes b. Note the static pressure and flow of the nearest hydrant if requested. c. Show location of proposed fire hydrants and meters. | X | X | X | X | X | X Underground or surface utility transmission lines: (Note: This category includes, but is not limited to telephone, electrical, natural gas, and TV cable) a. Locations of all related structures (pedestals, poles, etc.) b. Locations of all lines (note whether the line is below or above ground) c. A note shall be placed where streets will be placed under the existing overhead facilities and the approximate change in grade for the proposed street. | X | X | X | X State the width, location, and purpose of all proposed easements or rights of way for utilities, drainage, sewers, flood control, ingress/egress or other public purposes within and adjacent to the project. | X | X | X | X | X | X | X (8) Streets/Right-of-Ways/Easements. Preliminary Plat | Final Plat | Concurrent Plat | Property Line Adj. | Lot Split | Large-Scale, SIP, PZD | Concept Plat Street right-of-way lines clearly labeled. The drawing shall depict any future R.O.W. needs as determined by the AHTD and Master Street Plan. Future R.O.W. as well as existing R.O.W. and center lines should be shown and dimensioned. | X | X | X | X | X | X | X The location, widths, grades, and names of all existing and proposed streets (avoid using first names of people for new streets), alleys, paths, and other rights-of-way, whether public or private, within and adjacent to the project; private easements within and adjacent to the project; and the radius of each centerline curve. Private streets shall be clearly indicated and named. Names of streets should be approved by the 911 Coordinator. | X | X | X | X | X | X | X A layout of adjoining property (within 300 feet) in sufficient detail to show the effect of proposed and existing streets (including those on the Master Street Plan), adjoining lots, and off-site easements. This information can be obtained from the Master Street Plan, Aerial Photos, and the City Plat Pages located in the Planning Office if requested. | X | X | X | X | X The location of all existing and proposed street lights (At every intersection, cul-de-sac & every 300 feet and associated easements to serve each light.) | X | X | X | X (9) Subdivision of Land. Preliminary Plat | Final Plat | Concurrent Plat | Property Line Adj. | Lot Split | Large-Scale, SIP, PZD | Concept Plat The lot layout, the dimensions of each lot, number of each lot, total area in square footage or acreage to the nearest 1/100 th acre of each lot, and the approximate finish grade where pads are proposed for building sites. Lots shall be numbered consecutively for all phases. The total number of lots shall be indicated on the plat. | X | X | X | X | X | X For phased development, a plat showing all phases is required. | X | X | X | X (10) Site Specific Information. Preliminary Plat | Final Plat | Concurrent Plat | Property Line Adj. | Lot Split | Large-Scale, SIP, PZD | Concept Plat Provide a note of any known existing flooding and/or erosion problems on-site or within 300 feet downstream of the property. | X | X | X | X The location of known existing or abandoned water wells, sumps, cesspools, springs, water impoundments, and underground structures within the project. | X | X | X | X | X | X The location of known existing or proposed ground leases or access agreements, if known. (e.g., shared parking lots, drives, areas of land that will be leased). | X | X | X | X | X | X The location of all known potentially dangerous areas, including areas subject to flooding, slope stability, settlement, excessive noise, previously filled areas and the means of mitigating the hazards (abatement wall, signage, etc.). | X | X | X | X The boundaries, acreage, and the use of existing and proposed public areas in and adjacent to the project. If land is to be offered for dedication for park and recreation purposes it shall be designated. | X | X | X | X For residential development, indicate the use and list in a table the number of units and bedrooms. | X For non-residential development, indicate the gross floor area, and if for multiple uses, the floor area devoted to each type of use. | X The location and size of existing and proposed signs, if any. | X | X | X | X | X | X The location and number of bike racks provided and required. | X Location, size, surfacing, landscaping, and arrangement of parking and loading areas. Indicate pattern of traffic flow; include a table showing required, provided, and handicapped accessible parking spaces. | X Location and width of curb cuts and driveways. Dimension all driveways and curb cuts from side property line and surrounding intersections. | X Location of buffer strips, fences or screen walls, where required (check Unified Development Code for specific requirements). | X | X | X Indicate location and type of garbage service. Dimension turnaround area at dumpster location. | X | X A description of commonly held areas, if applicable. | X | X | X A written description of requested waivers or variances from any city requirement. | X | X | X | X | X | X Show required building setbacks. Provide a note on the plat of the current setback requirements for the subdivision. | X | X | X | X | X | X | X Preliminary grading and drainage plans and reports as required in the City Engineer's Office. | X | X | X (11) Other requirements. Preliminary Plat | Final Plat | Concurrent Plat | Property Line Adj. | Lot Split | Large-Scale, SIP, PZD | Concept Plat Any other data or reports as deemed necessary for project review by the Zoning and Development Administrator, City Engineer or Planning Commission. | X | X | X | X | X | X | X Signature block to certify approval of streets, drainage and utility easements. | X | X Signature block to certify approval of water and sewer system. | X | X Signature block to certify approval of building setback dimensions. | X | X Signature block certifying approval for recording. | X | X | X | X Signature block certifying approval of park land dedication or money in lieu. | X | X Signature block certifying approval of utility easements. | X | X Signature block certifying ownership, title and dedication. | X | X | X Signature block certifying survey and accuracy. | X | X | X (12) Easement Plat. Preliminary Plat | Final Plat | Concurrent Plat | Property Line Adj. | Lot Split | Large-Scale, SIP, PZD | Concept Plat Prior to the issuance of a building permit for a large scale development, site improvement plan or planned zoning district an easement plat shall be filed of record in the office of the Circuit Clerk dedicating all required easements and rights-of-way. | X *All plats should meet or exceed the most current State of Arkansas Standards of Practice for Property Boundary Surveys and Plats. **SIP = Large or Small Site Improvement Plan ***PZD = Planned Zoning District (C) Signatures Required. The final plat or concurrent plat may be signed by any officer of the Planning Commission. (D) Number of Plats. The Planning Division may require additional copies of plats if the amount required by this chapter is not sufficient for distribution to the various committee members.
(Code 1965, App. C., Art. III, §A(1); Ord. No. 2695, 1-20-81; Ord. No. 3080, 4-2-85: Ord. No. 3201, 8-5-86: Ord. No. 3315, 11-17-87; Code 1991, §§159.05, 159.30k.; Ord. No. 3578, 11-19-91; Ord. No. 3615, §1, 6-2-92; Ord. No. 3738, §1, 11-16-93; Ord. No. 3793, §1, 5-17-94; Ord. No. 3797, §1, 5-17-94; Ord. No. 4068, §1, 11-4-97; Ord. No. 4100, §2 (Ex. A), 6-16-98; Ord. No. 4199, 11-2-99; Ord. No. 4454, 01-07-03; Ord. No. 4545, 02-17-04; Ord. No. 4725, 7-19-05; Ord. No. 4864, 05-02-06; Ord. 5152, No. 7-15-08; Ord. No. 5215, 1-20-09; Ord. No. 5271, 9-1-09; Ord. 5296, No. 12-15-09; Ord. No. 6446, §8(Exh. C), 6-15-21)
Ask a question about Fayetteville law
Corpus searches the Fayetteville sections it holds and shows the ones that match, with their citations. Free, no sign-in.