§ 166.21 — Downtown Design Overlay District

Code of Ordinances of the City of Fayetteville, Arkansas (Codified through Ordinance No. 7010, enacted June 16, 2026 (Supp. No. 42)) · Fayetteville Code of Ordinances § 166.21

Corpus is an independent public-information project, not the official City of Fayetteville website. Stable reference: corpuslaw.us/code/64e2165f-2b5b-42ba-891d-7fc7945b2223

166.21 - Downtown Design Overlay District

(A) Purpose. The intent of this ordinance is to encourage good architectural form through the use of quality design and materials. The goal of the code is to promote functional architecture that creates attractive and usable space. Downtown Fayetteville has a rich architectural history spanning many decades and styles; therefore, architecture should be respectful of the existing built environment and should strive to enhance the public realm. A strong emphasis shall be placed upon designing and implementing sustainable and green architecture practices. (B) Applicability. The Downtown Design Overlay District applies to parcels of land located within the boundaries of the Downtown Design Overlay District. The Downtown Design Overlay District Architecture Standards are applicable in the following instances: (1) If a conflict occurs between different standards, these standards shall supersede the City's Nonresidential Design Standards; Office, and Mixed-use Design and Development Standards in the Downtown Design Overlay District and College Avenue Overlay District. (2) All new construction, additions or renovations shall comply with these standards regardless of whether the improvements require a permit; ordinary repairs and maintenance are not subject to these standards. Specifically, only the new construction or portions of the building that are being renovated shall comply with these standards. (3) Building designs that strictly comply with these standards are to be considered approved for matters of aesthetics and shall not require further discretionary review for architectural character or appearance. (4) Building designs that do not comply with these standards may be permitted by a variance after review and approval by the Planning Commission. (5) Building designs that are denied or approved by the Planning Commission may be appealed to the City Council. (C) Downtown Design Overlay District Manual. (1) The City of Fayetteville Downtown Overlay District Manual shall be used in support of this chapter to explain specific objectives and principles and to provide a resource for guidance in implementing these standards. (2) Copies of the Manual are to be made readily available to the public in the Planning Division. (D) Special Building Elements and Appurtenances. If a building has a marquee, awning, balcony, colonnade, arcade, turret, cupola, porch or stoop then it shall comply with the following regulations: (1) Marquees and Awnings. (a) Standard. These dimensional requirements apply to first or ground floor awnings and marquees. There are no minimum standards for awnings above the first floor. (i) Depth. To the back of the curb maximum. (ii) Height. 7 feet minimum clear. (b) Right-of-Way Encroachment. Marquees and awnings shall occur forward of the principal façade and may encroach within the right-of-way, in accordance with the Building Code adopted by the City of Fayetteville. (c) Placement. Placement of awnings or marquees shall not interfere with street trees, street lights, street signs, utilities or other such civic infrastructure. (d) Prohibited Materials. High-gloss or plasticized fabrics are prohibited. (2) Balconies. (a) Standard. (i) Depth. To the back of the curb maximum. Balconies above the second floor shall have a maximum projection of 4 feet from the principal façade. (ii) Height. 10 feet minimum clear to the underside of the horizontal floor. Supports or appendages may not extend below 7 feet clear. (iii) Length. 80% maximum of principal building façade for the second floor. 40% maximum for all balconies above the second floor. (iv) Roofs. Balconies may have roofs, but are required to be open, non-air conditioned parts of the building. (v) Underside. The underside of a balcony extending over a sidewalk shall be covered with a solid material and lighting may be required, depending upon the proximity to a street light. (b) Right-of-Way Encroachment. Balconies may encroach within the right-of-way, in accordance with the Building Code adopted by the City of Fayetteville. (c) Placement. Balconies shall not interfere with street trees, street lights, street signs, utilities, or other such civic infrastructure. (3) Colonnades and Arcades. (a) Standard. (i) Depth. 8 feet minimum from the principal façade to the inside of the column face. Columns must be setback 18 inches from the outside of the column face to the back of the curb. (ii) Height. 10 feet minimum clear. (iii) Length. 75—100% of the principal façade. (iv) Underside. The underside of a colonnade or arcade extending over a sidewalk shall be covered with a solid material and lighting may be required, depending upon the proximity to a street light. (b) Right-of-Way Encroachment. Colonnades shall only be constructed where the minimum depth can be obtained. Colonnades shall occur forward of the principal façade, and may encroach within the right-of-way, but shall not extend past 18 inches from the back of the curb, in accordance with the building code adopted by the City of Fayetteville. (c) Placement. Colonnades may replace street trees along their length. (4) Turrets and Cupolas. (a) Standard. (i) Area. 20 feet × 20 feet maximum footprint. (ii) Height. If the footprint is larger than 10 feet × 10 feet, then the cupola/turret may extend a maximum of 25 feet above the eave or top of the parapet of the highest story. If the footprint is less than 10 feet × 10 feet then the turret or cupola may extend to maximum of 50 feet above the eave or top of the parapet of the highest story. (5) Front Porches. (a) Standard. (i) Depth. 6 feet minimum from the principal façade to the inside of the column face. (ii) Length. 25 to 100% of the principal facade. Front porches may be multi-story and are required to be open or screened and non-air conditioned. (b) Right-of-Way Encroachment. Front porches may occur forward of the principal façade. Porches shall not extend into the right-of-way. Front porches and stoops shall not be built within 18 inches of the side property line on attached unit types. (6) Stoops. (a) Standard. Stoops may be covered or un-covered and stairs may run to the front or to the side. (i) Depth. 4 feet minimum from the principal façade to the inside of the column face for stoops with a covered landing. (ii) Height. 96 inches maximum. (iii) Length. Maximum 12-foot width for each individual building entrance or group of connected entrances. The pedestrian connection from the stoop to the public sidewalk shall be allowed to run from the door along the facade of the building, parallel to the street, for a maximum of 12 feet from the door, before connecting directly to the public sidewalk. (b) Right-of-Way Encroachment. Stoops may occur forward of the principal façade and may extend into the right-of-way in accordance with the building code adopted by the City of Fayetteville. (c) Placement. Sidewalks shall have a minimum 5 feet clear access for pedestrian movements. Stoops shall not be built within 18 inches of the side property line on attached unit types. (7) Projected Bay. (a) Standard. Bays shall consist of habitable space. (i) Depth. 4 feet maximum from the principal facade. (ii) Second Story Height. Bays above the first or ground floor shall have a minimum of 10 feet clear to the underside of the horizontal floor. Supports or appendages shall not extend below 7 feet clear. (iii) Length. 20% maximum of the principal façade length. (b) Second Story Right-of-Way Encroachment. Bays above the first or ground floor may encroach within the right-of-way, in accordance with the Building Code adopted by the City of Fayetteville. (c) Placement. Projected bays shall not interfere with street trees, street lights, street signs or other such civic infrastructure. (E) Exterior Architectural Elements. The lists of permitted materials and configurations have been selected for their durability, sustainability and responsiveness to climate. The primary goal of the Architectural Elements is authenticity; the elements encourage construction that is straightforward and functional and draws its ornament and variety from the assembly of genuine materials. Items not listed in the Architectural Elements may be approved upon review by the Planning Commission. (1) Rear Yards Only. The following shall only be located in the rear yard: (a) Trash dumpsters. (b) Trash and recycling carts and bins. (2) Exterior Prohibited Materials. The following shall be prohibited: (a) Undersized Shutters. Shutters shall be sized so as to equal the width required to cover the window opening. (b) Shutters made of plastic. (c) Glass with reflective coatings other than clear glass with Low-E coatings. (See opacity and façade section). (d) Plastic or PVC roof tiles. (e) Aluminum siding. (f) Vinyl siding. (g) Wood fiber board. (h) Unfinished pressure-treated wood. (i) EIFS (Exterior Insulation Finish System) located on the first or ground floor. (3) Columns, Arches, Pedestals, Railings and Balustrades. (a) Permitted Configurations. (i) Square columns shall have a minimum width of 6 inches with or without capitals and bases. (ii) Round columns shall have a minimum 6-inch outer diameter with or without capitals and bases. (iii) Pedestals shall have a minimum width of 8 inches. (b) Permitted Materials. (i) Columns and Pedestals. Brick, painted stained or natural wood, Terra Cotta, stained painted or un-painted concrete with a smooth finish, cast-in-place concrete with or without stucco, pre-cast concrete, fiber cement board, concrete masonry units with stucco, stone, structural steel, and cast iron. (ii) Arches and Lintels. Brick, painted stained or natural wood, Terra Cotta, stained painted or un-painted concrete with a smooth finish, cast-in-place concrete with or without stucco, pre-cast concrete, fiber cement board, concrete masonry units with stucco, stone, structural steel, and cast iron. (iii) Railings and Balusters. Brick, painted stained or natural wood, Terra Cotta, stained painted or un-painted concrete with a smooth finish, cast-in-place concrete with or without stucco, pre-cast concrete, concrete masonry units with stucco, stone, structural steel, cast iron, wrought iron, and glass. (4) Windows, Skylights, and Doors. (a) General Requirements. (i) Visible sills on the exterior of the building are required for all windows. (ii) Windows shall have trim on the sides and top when the exterior of the building is wood or lap sided. Window trim shall have a minimum dimension of 0.75 inches × 3.5 inches (a normal 1×4). (iii) A minimum of 10% of the window area per floor shall be operable with the exception of the first or ground floor. (b) Permitted Configurations. (i) All window configurations are allowed. (c) Permitted Finish Materials (i) Windows. Windows may be made of wood, aluminum, copper, steel, clad wood, thermally broken vinyl or aluminum. No false grids are permitted except for where mullions and muntins are permanently adhered to both the interior and exterior of a pane of thermally broken glass separated by a spacer aligned with the mullions or muntins in between panes of thermally broken glass. (Commonly referred to as simulated divided light windows). (ii) Doors. Doors may be made of wood, glass, fiberglass or metal. (I.e. steel, aluminum, copper, bronze, etc.) (iii) Sills. Brick, painted stained or natural wood, Terra Cotta, stained painted or un-painted concrete with a smooth finish, cast-in-place concrete with or without stucco, pre-cast concrete, fiber cement board, concrete masonry units with stucco, stone, structural steel, and cast iron. (5) Roofs and Gutters. (a) General Requirements. (i) Roofs may be gabled, hipped, mansard, shed, gambrel, barrel-vaulted, or domed. (ii) Applied mansard roofs are not permitted. (iii) Low sloped roofs (less than 1 in 12 pitch) shall have light colored finish materials. (b) Permitted Configurations. (i) Metal panel roofs shall expose the panel ends at the overhang. (ii) Gutters may be rectangular, square, half-round, or Ogee sections. (c) Permitted Finish Materials (i) Metal Roofs. Metal roofs may be made of galvanized steel, aluminum-zinc coated steel, copper, aluminum, zinc-alum, lead coated copper, terne, or powder coated steel. (ii) Shingles. Shingles shall be made of asphalt, metal, concrete, terrra-cotta, slate, or cedar shingles or shakes. (iii) Gutters and Downspouts. Gutters and downspouts shall be made of copper, aluminum, galvanized steel, aluminum-zinc coated steel, lead coated copper, terne, or powder coated steel. (6) Garden Walls, Fences and Hedges. (a) General Requirements. (i) Fences, garden walls, or hedges are permitted along side yards, rear yards, and all property lines which abut public streets or alleys. (ii) Fences in the front yard shall be not be 100% opaque and shall provide visible separation between the fence slats. Fences in a rear or side yard, at least 10 feet behind the principal façade of the primary structure, may be at a maximum 100% opaque. (b) Height. (i) Front yard (in front of the primary structure) maximum height of 42 inches. (ii) Fences located in the rear and side yards (behind the principal façade of the primary structure) shall have a minimum height of 36 inches and a maximum height of 8 feet. (c) Permitted Configurations. (i) Wood Fences. Vertical picket fences or horizontal slat fences with corner posts, and split rail fences; privacy fences are permitted in the rear and side yard only, behind the principal façade of the primary structure. (ii) Metal Fence. Fence shall be comprised of primarily vertical pickets with a minimum ⅝-inch diameter, and 4-inch maximum clear space between the pickets. (iii) Brick and Stone. (d) Permitted Finish Materials (i) Wood. (ii) Wrought iron, steel and cast iron. (iii) Brick and stone. (iv) Concrete masonry units with or without stucco so long as the primary structure corresponds. (v) Reinforced concrete with or without stucco as long as the primary structure corresponds. (7) Opacity and Facades. (a) General Requirements. (i) Each floor of any principal building façade above the first floor facing a park, square or street shall contain windows covering from 15% to 60% of the principal façade area. (ii) The permitted percentage of glass may be increased to 80% for any two floors above the fourth floor provided that there is a minimum stepback of 15 feet from the principal façade. (iii) A minimum of 10% of the window area per floor shall be operable with the exception of the first or ground floor. (iv) All glass shall have a Low-E coating. (v) Glass used above the first or ground floor shall have a visible transmittance rating of 0.4 or higher. (b) First or Ground Floor Requirements of Any Principal Façade. (i) Glass on the first or ground floor shall have a visible transmittance rating of 0.6 or higher. (ii) Commercial space and storefronts shall have a minimum of 75% glass on the first or ground floor. (iii) Office, institutional, and other non-residential space shall have a minimum of 50% glass on the first or ground floor. (iv) Multi-family residential space shall have a minimum of 40% glass on the first or ground floor. (v) Single-family and two-family residential space shall have a minimum of 5% glass on the first or ground floor. (vi) The measurement for glass percentage on the first or ground floor shall be calculated at the pedestrian level between 2—12 feet above the sidewalk. For a building façade located outside of a build-to zone the measurement for glass percentage on the first or ground floor shall be at the pedestrian level between 2 and 12 feet above the finished floor elevation (FFE). (vii) Doors or entrances for pedestrian access shall be provided at intervals no greater than 50 ft. apart along the principal façade.

(Ord. No. 5056, 9-04-07; Ord. No. 5679, 4-15-14; Ord. No. 6017, §1, 12-5-17)

Ask a question about Fayetteville law

Corpus searches the Fayetteville sections it holds and shows the ones that match, with their citations. Free, no sign-in.