Sec. 25-243. - FOG control devices.

(a) FOG control devices. All FOG control devices necessary for compliance with this division and the FOG wastewater discharge permit shall be installed, operated, and maintained at the FOG generator's expense. (b) FOG control device sizing. Plans for installation of all FOG control devices shall be submitted to and subject to approval by the control authority. Generally, the control authority shall be guided by the PDI G101, ASME A112.14.3 appendix A or ASME A112.14.4. (c) Grease recycling container. Unless the control authority approves alternative procedures, a grease recycling container must be provided and routinely serviced by a licensed grease retrieval service when a FOG generator's facility has a fryer, grill, or other cooking process that produces waste grease. It is a violation of this division to dispose of waste cooking grease by direct or indirect connection to the WCTS, and waste cooking grease may not be dumped directly into a FOG control device. (d) Existing facilities. An existing FOG generator in operation on the effective date which does not have a FOG control device is required to install a FOG control device, at the FOG generator's expense, within one year of the effective date. (e) Repair. If any FOG control device is found to be noncompliant with any division or permit standard or inadequate to prevent FOG discharges to the WCTS in excess of concentrations of 100 mg/l, the FOG generator, at the FOG generator's expense, shall repair or replace any noncompliant plumbing or the existing FOG control device within 90 days of written notification by the control authority. (f) Historic and extreme hardship restrictions. A FOG generator operating in a structure subject to architectural or historical restrictions or who will suffer extreme economic hardship in order to upgrade an existing FOG control device may keep the current FOG control device in place provided that all fresh air fixtures are tied into the current FOG control device, or install a FOG control device approved by the control authority. In the event of remodeling or if the FOG generator changes ownership, a FOG control device that complies with all applicable requirements of this division shall be installed. (g) Sampling. All FOG control devices shall have a sampling point on the effluent discharge side of the FOG control device to allow for observation, sampling, and measurement of wastewaters. The FOG wastewater discharge permit shall identify the sampling point location. The sampling point shall be maintained and kept safe and accessible to the control authority at all reasonable times. (h) FOG control device inspection. Not less frequently than once per permit cycle (once every two years), each FOG generator shall have a licensed plumber or other qualified professional approved by the control authority inspect each FOG control device. After evacuation of the FOG control device, the licensed plumber or other qualified professional approved by the control authority shall provide a written report of the inspection to the FOG generator and certify the FOG control device is operating properly. All defects found during the inspection shall be corrected by each FOG generator within 90 days of each inspection. (i) Notification of spills by the FOG generator. (1) In the event that any FOG generator is unable to comply with any permit condition due to a breakdown of equipment, accidents, human error, or the FOG generator has reasonable opportunity to know that his discharge shall exceed the discharge provisions of the FOG wastewater discharge permit or the regulations in this division, the FOG generator shall immediately notify the control authority by telephone at the number specified in the permit. If the material discharged to the sewer has the potential to cause or result in sewer blockages or sanitary sewer overflows, the FOG generator shall immediately notify the control authority by telephone at the number specified in the permit. (2) All FOG generators shall provide written notification of this oral or telephonic notification to the control authority at the address specified in the permit no later than five working days from the date of the incident. The written notification shall state the date of the incident, the reasons for the discharge or spill, what steps were taken to correct the problem, and what steps are being taken to prevent the problem from recurring. (3) Such notification shall not relieve a FOG generator of any expense, loss, damage, or other liability which may be incurred as a result of damage or loss to the city or any other damage or loss to person or property; nor will such notification relieve a FOG generator from payment of any fees or imposition of any other liability which may be authorized by this division or other applicable law.

(Code 1992, § 25-243; Ord. No. 89-16, 12-20-2016)

Ask a question about Fort Smith law

Corpus searches the Fort Smith sections it holds and shows the ones that match, with their citations. Free, no sign-in.