For AI agents: read the machine-readable documentation index at /llms.txt or the single-file full reference at /llms-full.txt.

§ 25-246 — Control authority compliance monitoring

Municipal Code of the City of Fort Smith, Arkansas (Codified through Ordinance No. 126-24, enacted December 3, 2024. (Supp. No. 4)) · Fort Smith Municipal Code § 25-246

Corpus is an independent public-information project, not the official City of Fort Smith website. Stable reference: corpuslaw.us/code/73dcd36c-485f-4dc4-a780-ba664e24e3e2

Sec. 25-246. - Control authority compliance monitoring.

(a) Inspections and authority to enforce regulations. (1) Right of entry; inspection and sampling. The control authority shall have the right to enter the premises of any FOG generator to determine whether the FOG generator is complying with all requirements of this division, any FOG wastewater discharge permit or order issued by the control authority. FOG generators shall allow the control authority reasonable access to all parts of the premises for the purposes of inspection, sampling, records examination and copying, and the performance of any additional duties. In the event of an emergency involving actual or imminent sanitary sewer overflow, the control authority may access adjoining businesses or properties that share a WCTS connection with a FOG generator in order to prevent or remediate an actual or imminent sewer overflow. (2) The control authority shall inspect FOG generators on both an unscheduled and unannounced basis or on a scheduled basis. Inspection of a FOG control device may be performed at frequencies necessary to protect the WCTS against the accumulation of FOG in an amount that would exceed the 25 percent rule, but at a minimum of once every two years. Inspection shall include all fixtures, equipment, food processing, and storage areas, and shall include a review of the processes that produce wastewater discharged from a facility through the FOG control device. Any deficiencies may be noted, including but not to be limited to: a. Failure to report changes in operations or wastewater constituents and characteristics; b. Failure to properly maintain the FOG control device; c. Failure to maintain logs, files, records, or access for inspection or monitoring activities; d. Failure to obtain or renew the FOG wastewater discharge permit in a timely manner; or e. Any other violations of the regulations of this division or state law that may require correction by the FOG generator. (b) Search warrants. If the control authority has been refused access to a building, structure, or property, or any part thereof, and is able to demonstrate probable cause to believe that there may be a violation of this division, or that there is a need to inspect and/or sample as part of a routine inspection and sampling program of the city designed to verify compliance with this division, any permit or an order issued by the control authority, or to protect the overall public health, safety and welfare of the community, the control authority may seek issuance of a search warrant from the District Court of Sebastian County, Arkansas, Fort Smith Division.

(Code 1992, § 25-246; Ord. No. 89-16, 12-20-2016)

Ask a question about Fort Smith law

Corpus searches the Fort Smith sections it holds and shows the ones that match, with their citations. Free, no sign-in.