For AI agents: read the machine-readable documentation index at /llms.txt or the single-file full reference at /llms-full.txt.

§ 33-102 — Definitions

The Code of the City of Tempe, Arizona (Supp. No. 34, Update 1: codified through Ordinance No. O2026.34, enacted June 25, 2026) · Tempe City Code § 33-102

Corpus is an independent public-information project, not the official City of Tempe website. Stable reference: corpuslaw.us/code/288bf13e-5e21-47b6-b405-2ce226eae183

Sec. 33-102. - Definitions.

The following words and terms, when used in this article, shall have the following definitions, unless the context clearly indicates otherwise: Approved means accepted by the department as meeting an applicable specification stated or cited in this article, and as suitable for the proposed use. Auxiliary water supply means any water supply on or available to the premises other than the public potable water supply, including, but not limited to, water from another purveyor's public potable water supply, treated effluent, wastewaters or industrial fluids. Backflow means the reversal of the normal flow of water caused by either backpressure or backsiphonage. Backflow prevention assembly means an assembly or means designed to prevent the reversal of the normal flow of water caused by either backpressure or backsiphonage. (a) Air gap means the unobstructed vertical distance through the free atmosphere between the lowest opening from any pipe or faucet supplying water to a tank, plumbing fixture, or other device and the flood level rim of said vessel. An approved air-gap shall be at least double the diameter of the supply pipe, measured vertically, above the overflow rim of the vessel, and in no case less than one (1) inch. (b) Reduced pressure principle assembly means an assembly of two (2) independently acting approved check valves together with a hydraulically operating, mechanically indepen-dent differential pressure relief valve located between the check valves and, at the same time, below the first check valve. The unit shall include properly located test cocks and tightly closing shutoff valves at each end of the assembly. The entire assembly shall meet the design and performance specifications as determined by a recognized laboratory and approved by the department for backflow prevention assemblies. To be approved, these assemblies must be readily accessible for in-line testing and maintenance. (c) Double check valve assembly means an assembly of two (2) independently operating approved check valves with tightly closing shutoff valves on each end of the check valves, plus properly located test cocks for the testing of each check valve. The entire assembly shall meet the design and performance specifications as determined by a recognized laboratory and approved by the department for backflow prevention assemblies. To be approved these assemblies must be readily accessible for in-line testing and maintenance. (d) Pressure vacuum breaker assembly means an assembly containing an independently operating loaded check valve and an independently operating loaded air inlet valve located on the discharge side of the check valve. The assembly will be equipped with properly located test cocks and tightly closing shutoff valves located at each end of the assembly. Backpressure means the flow of water or other liquids, mixtures or substances under pressure into the distribution pipes of a potable water supply system from any source or sources other than the intended source. Backsiphonage means the flow of water or other liquids, mixtures or substances into the distribution pipes of a potable water supply from any source other than its intended source caused by the reduction of pressure in the potable water supply system. Contamination (high hazard) means an impairment of the quality of the potable water by sewage, industrial fluids or waste liquids, compounds or other materials to a degree which creates an actual or potential hazard to the public health through poisoning or through the spread of disease. Cross-connection means any physical connection or arrangement of piping or fixtures between two (2) otherwise separate piping systems, one (1) of which contains potable water and the other nonpotable water or industrial fluids through which, or because of which, backflow may occur into the potable water system. This would include any temporary connections, such as swing connections, removable sections, four-way plug valves, spools, dummy section of pipe, swivel or change-over devices or sliding multiport tube. Pollution (low hazard) means the presence of any foreign substance (organic, inorganic or biological) in the water which tends to degrade its quality so as to constitute a hazard or impair the usefulness or quality of the water to a degree which does not create an actual hazard to the public health but which does adversely and unreasonably affect such waters for domestic use. Tester certified means a person who has completed a minimum of forty (40) hours of training and has passed a written and practical exam as part of a certification or re-certification process. Each person certified to make competent tests or to repair, overhaul and make reports on backflow prevention assemblies shall be conversant with the applicable laws, rules and regulations and have had experience in plumbing or pipe fitting or have other qualifications which are equivalent in the opinion of the department. Water, nonpotable means water which is not safe for human consumption. Water, potable means any water which, according to standards recognized by the City, is safe for human consumption. Water, service connection means the terminal end of the service connection from the public potable water system at its point of delivery to the user's water system. If a meter is installed at the end of the service connection, then the service connection shall mean the downstream end of the meter. Unprotected takeoffs from the service line will not be permitted upstream of any meter or any backflow prevention assembly located at the point of delivery to the user's water system. Service connection shall also include water service connection from a fire hydrant and all other temporary or emergency water service connections from the public potable water system.

(Ord. No. 87.57, § 33-200, 1-28-88; Ord. No. 95.19, 7-20-95; Ord. No. 2004.15, 4-29-04)

Ask a question about Tempe law

Corpus searches the Tempe sections it holds and shows the ones that match, with their citations. Free, no sign-in.