§ 33-105 — Premises or systems requiring approved backflow prevention assemblies

The Code of the City of Tempe, Arizona (Supp. No. 34, Update 1: codified through Ordinance No. O2026.34, enacted June 25, 2026) · Tempe City Code § 33-105

Corpus is an independent public-information project, not the official City of Tempe website. Stable reference: corpuslaw.us/code/b8241864-d544-457b-8810-417640a8af23

Sec. 33-105. - Premises or systems requiring approved backflow prevention assemblies.

(a) An approved backflow prevention assembly of the type specified in this section shall be the minimum installation of each service connection (whether from a fire hydrant, temporary regular or other water service connection) to the following type of premises or systems: Type of Assembly Required Premises Requiring Approved Backflow Prevention Assemblies | Double Check | Reduced Pressure | Air Gap | Pressure Vacuum Breaker Air craft and missile plants | X Animal clinics, animal grooming shops | X Automotive repair with steam and/or acid cleaning equipment or solvent facilities | X Auxiliary water systems (interconnected) | X Auxiliary water systems (noninterconnected) | X Beverage bottling plant | X Breweries | X Buildings greater than 3 stories or 34 feet in height (low hazard) | X Buildings greater than 3 stories or 34 feet in height (high hazard) | X Buildings with booster pumps or potable water storage (low hazard) | X Buildings with booster pumps or potable water storage (high hazard) | X Canneries, packinghouses and reduction plants | X Car wash facilities | X Central heating and air conditioning plants | X Chemical plants | X Chemically treated potable or nonpotable water systems | X Civil works (government-owned or operated facilities not open for inspection by the department) | X Commercial laundries | X Dairies and cold storage plants | X Dye works | X Film processing labs | X Food processing | X High schools and colleges | X Holding tank disposal stations | X Hospitals and mortuaries | X Medical and dental buildings | X Sanitariums, rest and convalescent homes | X Irrigation systems with chemical injection | X Irrigation systems (premises having separate systems) | X Labs using contaminating materials | X Manufacturing, processing and fabricating plants using contaminating materials | X Mobile home parks | X Motion picture studios | X Oil and gas production facilities | X Plating plants | X Power plants | X Radioactive materials processing | X Restricted, classified or other closed facilities | X Rubber plants | X Sand and gravel plants | X Sewage and storm drainage facilities | X Shopping centers | X Water trucks, hydraulic sewer cleaning equipment | X | X Any premises where a cross-connection is maintained | X (b) Fire protection systems will be required to have the following type of protection: Type of Assembly Required Premises Requiring Approved Backflow Prevention Assemblies | Double Check | Reduced Pressure | Air Gap | Pressure Vacuum Breaker Direct connection from public water system (noncontaminating) | X Direct connection from public water system (contaminating) | X With pump and/or storage tank | X With auxiliary supply | X (c) Any premises where water supplied by the City is subject to deterioration in sanitary quality and there is the potential for its entry into the public water system shall be protected as required by the department.

(Ord. No. 87.57, § 33-500, 1-28-88; Ord. No. 95.19, 7-20-95, Ord. No. 2004.15, 4-29-04)

Ask a question about Tempe law

Corpus searches the Tempe sections it holds and shows the ones that match, with their citations. Free, no sign-in.