For AI agents: read the machine-readable documentation index at /llms.txt or the single-file full reference at /llms-full.txt.

§ 8-117 — Building address, tenant suite and dwelling unit number assignment

The Code of the City of Tempe, Arizona (Supp. No. 34, Update 1: codified through Ordinance No. O2026.34, enacted June 25, 2026) · Tempe City Code § 8-117

Corpus is an independent public-information project, not the official City of Tempe website. Stable reference: corpuslaw.us/code/b26b2217-6d4b-450c-be64-49b3bea91bd2

Sec. 8-117. - Building address, tenant suite and dwelling unit number assignment.

117.1 Scope. The provisions of this section shall serve as the requirements for the assignment of addresses, building identification letters, tenant suite and dwelling unit numbers for buildings within the City of Tempe. 117.2 Intent. The purpose of this section is to establish a consistent method of assigning building identification to aid fire fighters and other emergency responders, provide for efficient access to property records and information, ensure conformance to the standards of the U. S. Postal Service, and our utility companies. 117.3 General address assignments. The Community Development Department is responsible for the assignment of addresses and building identification letters. New developments will be initially processed under the address and or parcel number assigned for each undeveloped parcel. The Building Safety Division will subsequently assign the final address or addresses while the project plans are under review and before building permits are issued with each building being suited at the time of permit review of a shell building. In addition, the Building Safety Division is responsible for the assignment of the individual tenant suite and dwelling unit numbers. Once assigned, all building addresses, building identification letters, tenant suite and dwelling unit numbers shall be forwarded by the Community Development Department to the Maricopa County Assessor's Office, U.S. Postal Service, Tempe Police Department and Fire Medical Rescue Departments, and all utility companies. The actual size, color, and field placement of addresses, tenant suite and dwelling unit numbers shall be as specified in the Tempe Zoning and Development code. Where access is by means of a private road and the building address cannot be viewed from the public way, a monument, pole or other approved sign or means shall be used to identify the structure. 117.4 Tenant suite and dwelling unit numbers processing procedure. To initiate this process the project must submit a separate site plan including the building layouts to the Building Safety Division for tenant suite and dwelling unit number assignment. This submittal shall consist of a properly scaled site plan depicting the site, building layouts, parking lots, building orientations, driveway locations, building exits, elevators, lobbies, and corridors. Proposed tenant layout plans may also be submitted with the required site plan to assist in the proper assignment of suite numbers. Plans shall be submitted in electronic format to [email protected] providing the same information as noted above. All tenant suite and dwelling unit numbers shall be assigned prior to permit issuance for any tenant improvements. 117.5 Tenant suite and dwelling unit number assignments. All tenant suite and dwelling unit spaces within multi-occupant, multi-family and multi-family mixed use buildings shall be assigned individual tenant suite and dwelling unit numbers. Separate street addresses shall not be assigned to multiple tenants in a single building. Exception: Existing buildings with tenant suite or individual address numbers that were approved prior to this current address policy except as noted in Section 117.7 of this code. 117.5.1 Tenant space layout. Retail and office buildings will be assigned a separate suite number for each 20-foot increment of space along the length of the building. Buildings that have tenant entrances on 2 or more sides will be assigned suite numbers on the entry sides of the building for each 20 foot increment of space. Reference lines will be drawn on the plan in to represent the 20 foot spacing. The reference lines shall determine the suite number a tenant improvement may use based on its proposed location within the building. Exceptions: 1. Mixed use buildings such as office/warehouse and similar mixed uses may be divided into increments of up to 40 feet. 2. Apartments, condominiums, and hotels/motels will be assigned a unit number for each dwelling or sleeping unit. 3. Townhouses without the availability of individual addresses will be assigned a unit number for each unit. The suite numbers assigned to these spaces represent the possible number of spaces that the building may be divided into and are not meant to represent the actual tenant space layouts. If a proposed tenant improvement encompasses multiple spaces, the tenant may choose any suite number within the range of suite numbers that the space will occupy. When a proposed tenant improvement that encompasses multiple spaces splits a space, the higher suite/unit number within the range may not be used by the tenant. 117.5.1.1 Accessory Dwelling Unit (ADU). No separate address shall be issued for an accessory dwelling, instead the unit shall be addressed with the letter "A" following the address of the principle dwelling. i.e., 1234 - A. The address shall be visible from the point of entry for the ADU. No more than one (1) attached and one (1) detached ADU is allowed on any lot that is less than one (1) acre per Section 3-402 of the Zoning and Development Code. 117.5.2 Numbering. Suite/unit numbers are assigned as three (3) digit numbers. The first digit in the suite number will represent the floor level of the suite/unit. Unit number are assigned as four (4) digit numbers for townhomes (without individual addresses), apartments and residential condominiums of nine (9) stories or less. Exception: Four-digit suite/unit numbers will be used for multi-occupant floors above the 9th floor, including multifamily residential condominiums and apartments. Duplicate unit numbers will not be used within multifamily projects, even if the project has more than one address or street entry. Projects containing multiple street addresses (areas) and containing a letter designation for each building will have unit numbers assigned sequentially throughout the project. When numbering sequentially from one area to another, each new area will commence its numbering with the next 100 series left off from the previous area. 117.5.3 Exterior tenant entrances. For buildings with exterior tenant entrances, the suite numbering shall follow the addressing guidelines based on the orientation of the building and its location in relation to Mill Avenue and the Salt River. 117.5.4 Interior tenant entrances. For buildings with suites only accessed through interior entrances, the suite numbering starts with 101 on the left side of the main entrance of access and continues clockwise around the corridor. For multiple floors, the suite numbering begins with the first suite on the left after exiting the elevator or main entry stairway for buildings with no elevator, and continuing clockwise around the corridor. When buildings have multiple floors, the first suite shall start with '01 numbers, such as 201, and 301, applicable to each floor level and shall start in the same general location as required for the first suite (101) on the ground floor then continue clockwise sequentially around the corridor. Exception: Single tenant spaces that occupy a complete floor level may be assigned the '00 number, such as 200 and 300, applicable to that floor level, provided that when the floor is occupied by two or more tenant spaces the numbers shall be reassigned to '01 numbering. 117.5.5 Basements. Basement suite/unit numbers shall be preceded with the letter B. 117.6 Non-conforming structures appeal process. Buildings and projects that cannot readily conform to these standards shall be reviewed on a case by case basis by a multi-disciplinary team made up an authorized member of the Police Department, Fire Medical Rescue Department, Community Development Department, and the U.S. Postal Service. Decisions rendered by this team may only be appealed through a formal application for a Code Modification. 117.7 Existing buildings. Buildings not in conformity with the current address policy may continue to utilize existing suite numbering until such time that the building is: 1. At or below a 50% vacancy rate; and 2. When a tenant improvement is proposed. Buildings not in conformity and with a proposed new tenant improvement after the building is at or below 50% vacancy rate shall be required to use the newly assigned suite numbers. The existing occupied suites will have twelve (12) months, from date of assignment, to conform to the newly assigned suite numbers. If a conflict in suite numbering exists because of re-suiting to the current policy, the building official or designee shall implement a suite numbering plan for the building which shall, as practicable, bring all suites into substantial compliance.

(Ord. No. O2018.59, § 1, 8-30-18; Ord. No. O2026.24, § 14(Exh. C), 6-4-26)

Ask a question about Tempe law

Corpus searches the Tempe sections it holds and shows the ones that match, with their citations. Free, no sign-in.