§ 9-29 — Initial testing procedures—Method to conduct tests
The Code of the City of Tempe, Arizona (Supp. No. 34, Update 1: codified through Ordinance No. O2026.34, enacted June 25, 2026) · Tempe City Code § 9-29
Corpus is an independent public-information project, not the official City of Tempe website. Stable reference: corpuslaw.us/code/2b587657-7df1-42b2-b846-9b2f0a77725f
Sec. 9-29. - Initial testing procedures—Method to conduct tests.
(a) Testing shall be performed by a city-approved RF Engineer. The City will provide a list of qualified RF Engineers. It is the responsibility of the building owner to contact the RF Engineer and make arrangements for testing. (b) Tests shall be made using frequencies close to the frequencies used by the city's Fire Medical Rescue Department and appropriate emergency services. If testing is performed on the actual frequencies, then this testing must be coordinated within the city's telecommunications unit. All testing must be performed on frequencies authorized by the FCC. A valid FCC license will be required if testing is performed on frequencies different from the city police, fire or emergency medical frequencies. (c) Measurements shall be made using the following guidelines: (1) With a service monitor using a unity gain antenna on a small ground plane; (2) Measurements shall be made with the antenna held in a vertical position at three (3) to four (4) feet above the floor; (3) Signal strength, both inbound and outbound as defined above, shall be measured on each and every floor above and below ground including stairwells, basements, penthouse facilities and parking areas of the structure. Each floor of the structure shall be divided into approximately twenty (20) equal test areas (test grid) and the measurements shall be taken at the center of each area. In critical zones (stairwells, lobbies, exit hallways, tunnels, below-ground service entrances, rooftop enclosures or any zone deemed critical by the Fire Code Official), the zone shall be divided into separate test areas with measurements taken every six (6) feet; (4) A calibrated service monitor (with a factory calibration dated within twenty-four (24) months) may be used to do the test; (5) The Fire Code Official or telecommunications unit representative for the City may also make simultaneous measurements to verify that the equipment is making accurate measurements. A variance of 3db between the instruments will be allowed; and (6) If measurements in one (1) location are varying, then average measurements shall be used. (d) All test results shall be submitted to the Fire Code Official, with a copy provided to the city Telecommunications Division, in the following format: (1) An E-size (arch E) floor plan view for each building level showing the location and signal strength for every measurement taken; and (2) Signal strength readings will be labeled on the plan inside a circle representing a ten (10) foot radius around each measurement point indicating any readings not meeting minimum in-building field strength as set forth in Sections 9-25 and 9-26 by an "x" through the circle. (e) Initial testing shall be performed at no expense to the City or appropriate emergency services department.
(Ord. No. 2001.25, 9-13-01; Ord. No. 2007.54, 8-16-07; Ord. No. O2014.09, 2-27-14; Ord. No. O2014.14, 3-20-14)
Ask a question about Tempe law
Corpus searches the Tempe sections it holds and shows the ones that match, with their citations. Free, no sign-in.