Sec. 9-31.1. - Post-treatment testing and proof of compliance.

(a) When an emergency responder radio amplification system is required, and upon completion of installation, the building owner shall have the radio system tested to ensure that two-way coverage on each floor of the building is a minimum of ninety-five percent (95%). The test procedure shall be conducted as described in Section 9-29. (b) Compliance and final acceptance will be determined using the following process: (1) The test shall be conducted using a calibrated service monitor and verified using a portable radio of the latest brand and model used by the agency talking through the agency's radio communications system; (2) Failure of a maximum of two (2) nonadjacent test areas shall not result in failure of the test; (3) In the event that three (3) of the test areas fail the test, in order to be more statistically accurate, the floor shall be permitted to be divided into forty (40) equal test areas. Failure of a maximum of four (4) nonadjacent test areas shall not result in failure of the test. If the system fails the forty-area test, the system shall be altered to meet the ninety percent (90%) coverage requirement; (4) A test location approximately in the center of each test area shall be selected for the test, with the test unit enabled to verify two-way communications to and from the outside of the building through the public agency's radio communications system. Once the test location has been selected, that location shall represent the entire test area. Failure in the selected test location shall be considered failure of that test area. Additional test locations shall not be permitted; (5) The gain values of all amplifiers shall be measured and the test measurement results shall be kept on file with the building owner so that the measurements can be verified during annual tests. In the event that the measurement results become lost, the building owner shall be required to rerun the acceptance test to reestablish the gain values; and (6) As part of the installation, a spectrum analyzer, or other suitable test equipment, shall be utilized to ensure spurious oscillations are not being generated by the subject signal booster. This test shall be conducted at time of installation and subsequent annual inspections. (c) All RF test results shall be submitted to the Fire Code Official, with a copy provided to the city Telecommunications Division, in the following format: (1) An E-size (arch E) floor plan view for each floor and confined space showing the location and signal strength for every measurement taken; (2) Signal strength readings will be labeled on the plan inside a shaded circle representing a ten (10) foot radius around each measurement point; and (3) Any readings not meeting minimum in-building field strength as set forth in Sections 9-25 and 9-26 will be noted by an "x" through the circle.

(Ord. No. O2014.09, 2-27-14)

Ask a question about Tempe law

Corpus searches the Tempe sections it holds and shows the ones that match, with their citations. Free, no sign-in.