13-63.1 - General Requirements.

a. General. Unreinforced masonry bearing wall buildings subject to this article shall undergo structural alterations necessary to comply with the minimum requirements set forth in this article within the time limits set forth in Table 13-63.5A. As an alternate, said buildings may be demolished if all necessary permits for demolition have been obtained, including a Certificate of Approval from the Historical Advisory Board, if applicable. EXCEPTION: Buildings which have undergone earthquake hazard reduction work which is deemed by the building official to be equivalent to the requirements set forth in this article need have no additional work performed. b. Change In Use. After the effective date of this article the time limits set forth in Table No. 13-63.5A shall not apply to any building which will undergo a change of use or occupancy which will result in the building being classified as a Group A Occupancy having an occupant load of one hundred (100) or more. Before such building may be used or occupied as a Group A Occupancy it shall be made to comply with provisions of this article. c. Wall Bracing. 1. General. Where the wall height to thickness ratio exceeds those allowed in Table 13-63.5C the wall must be laterally supported by vertical bracing members or by reducing the wall height by bracing. 2. Vertical Bracing Members. Vertical bracing members shall be attached to floor and roof construction for their design loads independent of required wall anchors. Horizontal spacing of vertical bracing members shall not exceed one-half (½) the unsupported height of the wall nor ten (10′) feet. Deflection of such bracing members at design loads, shall not exceed one-tenth of the wall thickness. 3. Wall Bracing. The wall height may be reduced by bracing elements connected to a floor or roof. Horizontal spacing of the bracing elements and wall anchors shall be as required by design and shall not exceed six (6′) feet on center nor six (6) times the wall thickness, whichever is less. Bracing elements shall be detailed to minimize the horizontal displacement of the wall by the vertical displacement of the floor or roof.

(Ord. No. 2573 N.S. § 1)

Ask a question about Alameda law

Corpus searches the Alameda sections it holds and shows the ones that match, with their citations. Free, no sign-in.