13-63.2 - Minimum Requirements.

a. Wall Anchorage. 1. General. Wall anchors shall be installed in unreinforced masonry walls at each roof and floor level as required by this article and shall be designed to resist the lateral forces specified by this article. Existing rod anchors, tension anchors, combination tension and shear anchors, or embedment bolts, which comply with the material requirements of this article may be used as wall anchors. Wall anchors shall be adequately secured to rafters or joists in order to transfer the required forces into the roof or floor sheathing. 2. Wall Anchor Spacing. The spacing for wall anchors shall not exceed six (6) times the wall thickness and in no case shall exceed six (6′) feet. Wall anchors may not be installed closer than twelve (12″) inches to the top of any unreinforced masonry wall. If a reinforced concrete beam is provided at the top of the wall, anchors may be installed to within six (6″) inches of the top of the wall. 3. Anchors at Corners. At the roof and floor levels, combination tension and shear anchors shall be provided within two (2′) feet horizontally from the inside of the corners of the walls. 4. Minimum Wall Anchorage Force. Anchorage of masonry walls to each floor or roof shall resist a minimum force determined by Formula (10-1) or two hundred (200) pounds per linear foot, whichever is greater, acting normal to the wall at the level of the floor or roof. b. Parapet Bracing. Parapets and exterior wall appendages not capable of resisting the forces specified in this section shall be removed, stabilized or braced to insure that the parapets and appendages remain in their original position. The maximum height of an unbraced unreinforced masonry parapet above the level of wall anchors shall not exceed one and one-half (1 ½) times the thickness of the parapet wall. If the parapet height exceeds this maximum height, a bracing system designed for the force determined by Formula (10-1) shall be installed to support the parapet. Parapet corrective work shall be performed in conjunction with the installation of tension roof anchors. c. Veneer. 1. Unreinforced masonry walls which carry no design loads other than their own weight may be considered as veneer if they are adequately anchored to new supporting elements. 2. Veneer shall be anchored with approved anchor ties, conforming to the required design capacity specified in this Code and placed at a maximum spacing of twenty-four (24″) inches with a maximum supported area of two (2) square feet. EXCEPTION: Existing veneer anchor ties may be acceptable provided the ties are in good condition and conform to the following minimum size, maximum spacing and material requirements. Existing veneer anchor ties shall be corrugated galvanized iron strips not less than one inch in width, eight inches in length and one-sixteenth of an inch in thickness (1″x 8″ x 1/16 ″) or equal and shall be located in every alternate course in the height of the wall at a spacing not to exceed eighteen (18″) inches on centers horizontally. As an alternate, such ties may be laid in every fourth course vertically at a spacing not to exceed nine (9″) inches on centers horizontally. 3. The location and condition of existing veneer ties shall be verified as follows: (a) An approved testing laboratory shall verify the location and spacing of the ties and shall submit a report to the Building Official for approval as a part of the structural analysis. (b) The veneer in a selected area shall be removed to expose a representative sample of ties (not less than four (4)) for inspection by the Building Official.

(Ord. No. 2573 N.S. § 1)

Ask a question about Alameda law

Corpus searches the Alameda sections it holds and shows the ones that match, with their citations. Free, no sign-in.