For AI agents: read the machine-readable documentation index at /llms.txt or the single-file full reference at /llms-full.txt.

§ 13-63.3 — Structural Analysis

Municipal Code of the City of Alameda, California (Codified through Ordinance No. 3398 N.S., passed April 21, 2026. (Supp. No. 74)) · Alameda Municipal Code § 13-63.3

Corpus is an independent public-information project, not the official City of Alameda website. Stable reference: corpuslaw.us/code/3a88544f-41fb-497e-a356-719a7cc72c72

13-63.3 - Structural Analysis.

a. General. The owner of each building within the scope of this Chapter shall cause a structural analysis of the building to be made by a civil or structural engineer or architect licensed by the State of California. If the building does not meet the minimum earthquake standards specified in this Chapter, the owner shall either cause it to be structurally altered to conform to such standards; or shall initiate proceedings for demolition of the building. b. Submittal of Analyses. Within seven hundred thirty (730) days after the service of the order, specified in this article the owner shall comply with the requirements set forth in this subsection by submitting to the Building Official either of the following: 1. A structural analysis and supporting test data which shall demonstrate that the building meets the minimum requirements of this article; 2. A structural analysis, supporting test data and plans for proposed structural alterations necessary to make the building comply with the minimum requirements of this article; or 3. An application for the demolition of the building. c. Certification of Analysis. The Building Official shall review the structural analysis submitted and determine whether all requirements of this article are satisfied. Once it is determined, the analysis is acceptable, a Certification stating that said analysis conforms with the requirements of this article shall be prepared by the Building Official. A copy of this Certification along with copies of the Structural Analysis and plans showing proposed structural alterations will be required in order to obtain a building permit for this work. d. Detailed Design Requirements. 1. Lateral Force on Elements of Structures and Nonstructural Components. Parts or portions of structures, nonstructural components and their anchorage to the main structural system shall be designed for lateral forces in accordance with the following formula: Fp = CpWp .....(10-1) Where: Wp = weight of an element or component Cp = as set forth in Table No. 1446 B 2. Height to Thickness Limitations. Unreinforced masonry wall height to thickness ratios shall not exceed the ratios set forth in Table No. 13-63.5C. If a wall height to thickness ratio exceeds the specified limits, the wall shall be laterally supported by bracing members designed in accordance with this article.

(Ord. No. 2573 N.S. § 1)

Ask a question about Alameda law

Corpus searches the Alameda sections it holds and shows the ones that match, with their citations. Free, no sign-in.