§ 15.17.060 — Section R403 amended—Footings
Municipal Code of the City of Bakersfield, California (Bakersfield Municipal Code current through Ordinance 5223, passed August 26, 2026 (municipal.codes publication, scraped 2026-11-17)) · Bakersfield Municipal Code § 15.17.060
Corpus is an independent public-information project, not the official City of Bakersfield website. Stable reference: corpuslaw.us/code/394f0d92-3440-4061-9337-ab717bc43b72
15.17.060 Section R403 amended—Footings.
Section R403.1.2 is amended to read as follows: R403.1.2 Continuous footing in Seismic Design Categories D0, D1 and D2. The braced wall panels at exterior walls of buildings located in Seismic Design Categories D0, D1 and D2 shall be supported by continuous footings. All required interior braced wall panels in buildings shall be supported by continuous footings. The second paragraph of Subsection R403.1.3 is added to read as follows: All concrete floor slabs poured on earth, for buildings of group R occupancies, including garage floor slabs, shall be reinforced with a welded wire fabric of 6 x 6-10/10 minimum weight or an approved equal.
Ask a question about Bakersfield law
Corpus searches the Bakersfield sections it holds and shows the ones that match, with their citations. Free, no sign-in.