§ 15.17.110 — Section R606 amended—General masonry construction
Municipal Code of the City of Bakersfield, California (Bakersfield Municipal Code current through Ordinance 5223, passed August 26, 2026 (municipal.codes publication, scraped 2026-11-17)) · Bakersfield Municipal Code § 15.17.110
Corpus is an independent public-information project, not the official City of Bakersfield website. Stable reference: corpuslaw.us/code/c74ccd15-f9a5-47cb-9322-85d8a9a8c3ba
15.17.110 Section R606 amended—General masonry construction.
Subsection R606.4.4 is amended to read as follows: R606.4.4 Parapet Walls. Unreinforced solid masonry parapet walls shall not be less than 8 inches (203 mm) thick and their height shall not exceed four time their thickness. Unreinforced hollow unit masonry parapet walls shall not be less than 8 inches (203 mm) thick, and their height shall not exceed three times their thickness. Masonry parapet walls in areas subject to wind loads of 30 pounds per square foot (1.44 kPa) or located in Seismic Design Category D0, D1, or D2 or on townhouses in Seismic Design Category C shall be reinforced in accordance with Section R606.12.
Ask a question about Bakersfield law