15.17.090 Section R503 amended—Floor sheathing.
Subsection R503.2.4 is added to read as follows: R503.2.4 Openings in horizontal diaphragms. Openings in horizontal diaphragms with a dimension perpendicular to the joist that is greater than 4 feet (1.2 m) shall be constructed in accordance Section 2308.11.3.3 of the California Building Code. Openings shall be further limited in accordance with Section R301.2.2.2.5.