For AI agents: read the machine-readable documentation index at /llms.txt or the single-file full reference at /llms-full.txt.

§ 18.150.140 — Setbacks

Concord Municipal Code (Current through Ordinance 26-2, passed September 8, 2026) · Concord Municipal Code § 18.150.140

Corpus is an independent public-information project, not the official City of Concord website. Stable reference: corpuslaw.us/code/5ba599b3-99aa-4807-a5a1-fd7e587c1f45

18.150.140 Setbacks.

A. Purpose. This section provides standards for measuring setbacks and exceptions to required setbacks for structures on residential properties. B. General Requirements and Exceptions. Structures on residential properties shall comply with the setback requirements of the applicable zoning district established by Division II of this title (Zoning Districts – Uses and Standards) or with the setback requirements under a specific plan, subdivision map, or other entitlement for the subject property, with the following exceptions: 1. Architectural projections as allowed in subsection (D) of this section; 2. Fences or walls in compliance with CDC 18.150.040 (Fences and walls); 3. Decks, freestanding solar devices, pavement, and other site design elements placed directly upon grade which do not exceed a height of 18 inches above finished grade; 4. Accessory structures in compliance with CDC 18.200.030 (Accessory structures); 5. Retaining walls less than 36 inches in height above finished grade; 6. Pools, ponds, and spas less than 18 inches in height above finished grade that meet the requirements of CDC 18.150.160 (Swimming pools, hot tubs, and spas); or 7. Other stand-alone structures that are less than six feet in height. C. Measurement of Setbacks. Setbacks shall be measured and applied as follows, unless different setback measurement methods are required due to an unusual parcel configuration that makes the following infeasible or ineffective. 1. Corner Lot. The front property line on a corner lot shall be the most narrow lot line abutting a street. If the property lines on both frontages are the same length, the property line to be used for the front setback measurement shall be that to which the city has assigned a street address. 2. Flag Lot. For lots with a fee ownership strip extending from a street or right-of-way to the building area of the lot, the front setback shall be measured from the nearest point of the wall of the structure to the point where the access strip meets the bulk of the lot; establishing a setback line parallel to the lot line nearest to the public street or right-of-way. FIGURE 18.150.140(A) – FLAG LOT SETBACK 3. Front and Street Side Setback. The setback from the front or street side yard shall be measured from the nearest point on the property line abutting the street right-of-way or private road easement to the nearest point of the wall of the structure. 4. Interior Side Setback. The interior side setback shall be measured at right angles from the nearest point on the side property line of the lot to the nearest point of the wall of the structure, establishing a setback line parallel to the side property line and extending between the front and rear setbacks. 5. Rear Setback. The rear setback shall be measured at right angles from the nearest point on the rear property line to the nearest line of the primary building, establishing a setback line parallel to the rear property line. a. The planning division shall determine the location of the required rear setback on a double-frontage lot. b. Where a lot has no rear lot line because the side lot lines converge to a point, a presumed line 10 feet within the parcel, parallel to, and at a maximum distance from the front lot line, shall be deemed to be the rear yard setback. (See Figure 18.150.140(B).) FIGURE 18.150.140(B) – DETERMINING SETBACKs c. For single-story additions to existing single-family homes in the RS-7, RS-7.5, and RS-8 zoning districts, the rear yard setback may be reduced to 15 feet, when all of the following criteria are met: i. The side yard setbacks conform to the required setbacks for the subject zoning district; ii. There is an open usable rear yard with a minimum dimension (length or width) of 20 feet; iii. There is an open usable rear yard with a minimum area equal to 10 times the minimum lot width required by the applicable zoning district; and iv. The existing and proposed improvements do not exceed the maximum lot coverage. d. The required rear yard setback for a single-family residence may be met by averaging the setback on a single site, to achieve the required setback, when: i. No more than 50 percent of the residence extends closer than the required setback; or ii. No portion of the residence extends closer than 15 feet to the rear property line. 6. Front Setback Averaging. Lots in areas where existing development has front setbacks less than required by the applicable district may reduce the required front setback as follows: a. On a site situated between two developed lots, the minimum front yard setback shall be the average depth of the two front yards on either side. b. Where a site is not situated between lots improved with buildings and where lots comprising 40 percent of the block frontage are improved with buildings, the minimum front yard setbacks shall be the average of the existing front yard depths on the block. c. In computing average front yard setbacks, a depth of 10 feet shall be used for lots with front yard setbacks that are less than 10 feet. For an interior lot in a residential zoning district that adjoins a lot on the same street frontage, but in a different zoning district, the required front setback on the interior lot may be reduced to not less than the average of the required depth and the width or depth of the setback required on the parcel in the other zoning district. 7. Determination of Setbacks on Irregular-Shaped Lots. The planning division shall determine setbacks for irregular-shaped lots that are not covered by any of the above examples on a case-by-case basis. D. Projections into Setbacks. Where allowed in the applicable district, an architectural feature that is part of the primary structure may extend beyond the wall of the structure and into a required front, street side, side, or rear setback in compliance with Table 18.150.140. These requirements do not apply to accessory structures subject to Division V of this title (Standards for Specific Uses). Table 18.150.140 Allowed Projections Into Setbacks | Projecting Feature | Allowed Projection into Required Setback | Front/Street Side Setback | Interior Side Setback | Rear Setback | Awnings and canopies | 6 feet | 30 inches(1) | 6 feet(1) | Balcony, landing, porch, stairway – Uncovered, unenclosed, and less than 30 inches above grade | 25 percent of setback | Balcony, landing, porch, stairway – Covered and enclosed by roof and walls | Not allowed in any setback | Balcony, landing, porch, stairway – Covered but unenclosed | 6 feet | 30 inches(1) | 6 feet(1) | Bay window, or similar projecting feature | 30 inches | The greater of 30 inches or 20 percent of setback(1) | 30 inches | Chimney/fireplace, six feet or less in breadth, media niche | 24 inches | 24 inches(1) | 24 inches(1) | Chimney/fireplace, more than six feet in breadth, media niche | Not allowed in any setback | 24 inches(1) | 24 inches(1) | Cornice, eave, mechanical equipment, roof overhang | 24 inches | 24 inches(1) | 24 inches(1) 1. May project an additional six inches if the setback is greater than five feet. E. Uses within Setback Areas. 1. Play Structures, Freestanding Solar Devices. A deck, freestanding solar device, or other site design element that exceeds a height of 18 inches above the finished grade at any point shall comply with the setback requirements for the primary structure, except as provided in CDC 18.200.030, Accessory structures. 2. Mechanical Equipment. Ground-mounted mechanical equipment shall comply with the setback requirements of the applicable district. Examples of this equipment include HVAC units, swimming pool pumps and filters, ventilation, and similar equipment; and cable television distribution boxes, transformers, and other utility equipment that is not installed underground, unless within the public right-of-way and approved by the city. 3. Storage. No front, rear, side, or street side setback shall be used for the accumulation, placement, or storage of automobiles or other motor vehicles, building materials, junk, machinery, or scrap, except for the following: a. Automobiles and trucks, not in excess of one-ton capacity regularly in use, with current registration, able to move under their own power, and be legally driven on a public street that are parked within a designated driveway; and b. Building materials stored on site required for construction on the subject parcel immediately before and during a construction project. 4. Parking. Except in single-family residential districts, parking shall not be located within a required front or exterior side setback area. 5. Storage of Trailers, RVs, and Larger Trucks Prohibited. All trailers and recreational vehicles as defined in Chapter 18.20 CDC, Article II (Use Classifications) and/or trucks not customarily used for personal use shall be stored or parked outside of the required front yard setback area, except in compliance with CDC 18.160.160 (Parking and storage of recreational vehicles). [Ord. 13-5; Ord. 12-4. DC 2012 § 122-307].

Ask a question about Concord law

Corpus searches the Concord sections it holds and shows the ones that match, with their citations. Free, no sign-in.