For AI agents: read the machine-readable documentation index at /llms.txt or the single-file full reference at /llms-full.txt.

§ 18.150.180 — Transitional requirements

Concord Municipal Code (Current through Ordinance 26-2, passed September 8, 2026) · Concord Municipal Code § 18.150.180

Corpus is an independent public-information project, not the official City of Concord website. Stable reference: corpuslaw.us/code/d6ef1ee1-0a86-441b-9a03-e6db0d3f62ef

18.150.180 Transitional requirements.

A. Purpose. This section provides standards for additional setbacks, screening, and landscaping to provide an appropriate transition between abutting properties. B. Applicability. All projects requiring a planning permit shall comply with these transitional requirements, except for planning permits related to a single-family residence, such as a variance or minor exception, provided the subject property is not part of a multi-lot subdivision approved with transitional requirements. C. Setbacks. The following setbacks shall apply to all nonresidential, mixed-use, and multifamily residential buildings abutting a residential district. 1. Buildings 30 feet or less in height shall have interior side and rear setbacks equal to the side and rear setbacks required in the abutting residential district. 2. Buildings exceeding 30 feet in height shall have a minimum setback of 20 feet, plus one additional foot of setback for every foot of building height over 30 feet, up to a maximum setback of 40 feet. Portions of the building above 30 feet may be staggered to comply with the additional setbacks, as shown in the following figure. FIGURE 18.150.180 – TRANSITIONAL HEIGHT AND SETBACK Table 18.150.180 Transitional Fence and Wall Requirements | Proposed Use | Adjoining Use | Required* | Residential | Residential | 6-foot fence | Commercial, office, retail, public/quasi-public with no outdoor storage or uses | 8-foot wall | Business park and industrial with no outdoor operations or storage | 8-foot wall | Any use with outdoor operations or storage | 8-foot wall | Street with four or more lanes | 6-foot wall | Street with three or fewer lanes | 6-foot fence | Commercial, office, retail, public, or quasi-public use with no outdoor operations or storage | Residential | 8-foot wall | Commercial, office, retail, public/quasi-public with no outdoor operations or storage | 6-foot wall | Business park and industrial with no outdoor operations or storage | 6-foot wall | Any use with outdoor operations or storage | 6-foot wall | Business park and industrial with no outdoor operations or storage | Residential | 8-foot wall | Commercial, office, retail, public/quasi-public with no outdoor operations or storage | 6-foot wall | Business park and industrial with no outdoor operations or storage, or vacant land zoned for such uses | 6-foot wall | Any use with outdoor operations or storage | 6-foot wall | All uses with no outdoor operations or storage | Vacant property | None | All uses with outdoor operations or storage | All uses | 6- to 8-foot wall; Also see CDC 18.150.120, Outdoor storage, for additional standards *Unless otherwise approved by the review authority. D. Fencing and Walls. Proposed developments shall provide a solid masonry wall or wood fence in accordance with the following table and standards. 1. All walls and fencing shall comply with CDC 18.150.040 (Fences and walls). 2. Walls shall be architecturally treated on both sides, as approved by the planning division. 3. Landscaping adjacent to masonry walls shall comply with Chapter 18.165 CDC (Landscaping). 4. This requirement may be waived, or an alternate method of compliance approved, if the review authority determines any of the following: a. The relationship of the proposed uses makes screening unnecessary; b. The intent of this subsection can be better met by alternative screening methods, including site planning, building orientation, additional setbacks, and landscaping; c. Physical characteristics and/or constraints on the site make the required screening infeasible or impractical. 5. The wall or fence requirement under Table 18.150.180 may be increased in height or upgraded to an alternative wall or fence type, if the review authority determines any of the following: a. The alternative wall or fence is necessary due to noise, light trespass, privacy, security, maintenance, or other concerns particular to the use or surrounding area; and b. The alternative wall or fence is necessary due to the physical characteristics of the site or surrounding properties, such as topography and existing improvements. E. Landscaping. A landscape buffer shall be provided between active uses (e.g., parking and loading areas) and the abutting residential district in accordance with CDC 18.165.060, Parking lot landscaping. [Ord. 12-4. DC 2012 § 122-311].

Ask a question about Concord law

Corpus searches the Concord sections it holds and shows the ones that match, with their citations. Free, no sign-in.