§ 18.150.150 — Solid waste and recycling storage
Concord Municipal Code (Current through Ordinance 26-2, passed September 8, 2026) · Concord Municipal Code § 18.150.150
Corpus is an independent public-information project, not the official City of Concord website. Stable reference: corpuslaw.us/code/99b71f0b-6d43-4109-aa31-1e44b3923acf
18.150.150 Solid waste and recycling storage.
A. Purpose. This section provides standards in compliance with the California Solid Waste Reuse and Recycling Access Act (Public Resources Code Sections 42900 through 42911). B. Applicability. These requirements shall apply to all multifamily and nonresidential development in addition to all applicable requirements of the city’s franchised waste hauler, this development code, and Chapter 8.20 CMC, Solid Waste. C. General Standards. Solid waste and recycling bins shall be stored within a fully enclosed structure that meets the following requirements. 1. The enclosure design shall be architecturally compatible with the other structures on site; 2. Trash enclosures shall be constructed with a minimum six-foot-high masonry wall or comparable solid material that screens bins from public view; 3. Access gates constructed of solid metal material or view-obscuring perforated metal. Gates shall swing outward more than 90 degrees without encroaching into, or interfering with the use of, adjacent improvements such as landscaping, parking, walkways, and driveways; 4. All trash enclosure areas shall be provided with a solid roof cover, constructed of materials and design compatible with the other structures on site; 5. Screening or other materials shall be provided to enclose any gap between the roof and the wall of the enclosure to prevent access; 6. A minimum six-inch concrete slab foundation shall be located in front of the enclosure and a concrete curb stop set a minimum of six inches shall be located inside of each wall; 7. A rubber or wood bumper located midway on each wall to protect the wall from damage; 8. All enclosures shall be provided with a drainpipe connecting to the sanitary sewer, in accordance with the requirements of the city’s franchised waste hauler; and 9. The enclosure shall be designed to accommodate two containers with at least 50 percent of the area for recycling and, if green waste is generated, additional space shall be provided; 10. Enclosures shall be located: a. Outside of any required parking, driveway, landscape, utility easement, or setback area, unless there is no feasible alternative; b. A minimum of five feet from an adjacent parking space; c. A minimum of 20 feet from the property line of an abutting single-family residential district; and d. A minimum of 20 feet from the public right-of-way line or access easement; 11. Enclosures shall be maintained by the property owner or manager in a good, usable, clean and sanitary condition. D. Additional Standards. 1. Enclosures for recycling bins shall comply with the following: a. Recycling bins shall be located in the same enclosure as solid waste containers wherever possible. If, due to space limitations or other property constraints, the bins must be in separate locations, the recycling and green waste containers shall be located so they are as convenient as the solid waste containers. b. The property manager or homeowners’ association representative, or other appropriate agent of the owner or owners of each residence at the time a lease or rental agreement is signed, is required to inform all new tenants of the availability of recycling, the location of the recycling collection site(s), and the materials that can be recycled. 2. Enclosures for multifamily residential and mixed-use projects shall comply with the following: a. In mixed-use projects, residential and nonresidential bins shall be located in separate areas. b. Enclosures shall be located within a walking distance of 150 feet from the door of any dwelling unit, except for units served by chute(s) located within the required distance that access both solid waste and recycling enclosures. c. Enclosures shall be located a minimum of 20 feet from any dwelling unit. d. Tenants and/or employees shall have convenient access (i.e., through a pedestrian opening) to bins without having to open the main enclosure gates. E. Enclosure Review Procedures. 1. The enclosure shall be submitted to the planning division and the city’s franchised hauler for review and approval of the proposed design, size, location, number, type, and placement of solid waste, recycling and green waste bins, boxes, and containers. 2. The planning division shall assure plans conform to the enclosure design and construction requirements in this section. In addition to these requirements, plans shall conform to design, building code, and other regulatory requirements. 3. The planning division shall approve such plans, require modifications, or impose additional requirements necessary for the safe and efficient collection of solid waste, recycling and green waste materials. [Ord. 12-4. DC 2012 § 122-308].
Ask a question about Concord law
Corpus searches the Concord sections it holds and shows the ones that match, with their citations. Free, no sign-in.
