Sec. 23-190. - Gravity separation interceptors.

(a) Any person so required by the public works director shall install and maintain a gravity separation interceptor. (b) A gravity separation interceptor must meet the following specifications: (1) Unless otherwise specific in this section, interceptors shall have an operational fluid capacity of not less than 100 gallons. a. Food processing facilities shall have interceptors with a minimum fluid capacity of 750 gallons, or as required by appendix H of the latest edition of the California Plumbing Code, whichever is greater. b. Vehicle servicing facility with the capacity for washing or cleaning more than one vehicle at a time, the interceptor shall be as large as necessary so that a seven-day accumulation of sand and oil together will not fill more than 25 percent of the fluid capacity. (2) Interceptors shall be watertight, structurally sound and durable. (3) Interceptors shall be designed so as to retain any material, e.g., oil and grease, which will float and any material, e.g., sand, which will settle. (4) Interceptors of less than 750 gallons capacity and interceptors for food processing facilities shall have two chambers. (5) Interceptors of 750 gallons capacity or larger, except those designed for food processing facilities, shall have a minimum of two chambers. (6) All interceptor chambers shall be immediately accessible at all times for the purpose of inspection and cleaning. At no time shall any material, debris, obstacles or obstructions be placed in such a manner so as to prevent immediate access to the interceptor. (7) All interceptors shall be equipped with a sample chamber located at the downstream end of the final interceptor unit. The sample chamber shall have a minimum 24-inch clear round opening and a 47-inch height minimum for the temporary installation of the city's portable automatic sampling equipment. (8) All domestic wastewater from restrooms, showers, and drinking fountains shall be kept separate until the nondomestic wastewater has passed through the interceptor. (9) Two-way cleanouts shall be installed between the building and interceptor, and downstream of sample box. See section 23-253 regarding cleanouts. (c) Interceptors legally and properly installed before December 18, 1990, shall be acceptable as an alternative to the interceptor specified in this section, provided such interceptor is effective in removing floatable and settleable material and is so designed and installed that it can be inspected and properly maintained. This subsection shall not apply to interceptors required by sections 23-161 and 23-163. (d) If the building official or public works director finds that an interceptor is incapable of adequately retaining the floatable and settleable material in the wastewater flow, is structurally incomplete, or is undersized, he shall condemn such interceptor and declare that it does not meet the requirements of this section and shall require the user to install, at the user's expense, an acceptable interceptor. (e) If a gravity separation interceptor is required, the building official shall only approve plumbing plans which include an interceptor which meets the requirements of this section. (1) Interceptor and sample box manufacturer specifications shall be included in the plan submittal. Equipment must be installed to match the approved design plan specifications. Any deviation in manufacturer, type, location, layout, or design will require prior approval by building official and public works director through the plan check process. Equal or equivalent pretreatment equipment installations will not be accepted without prior approval through plan check process. (f) Maintenance. Any user who owns, operates or maintains a gravity separation interceptor shall maintain it according to the user's wastewater discharge permit or as necessary to ensure that sediment and floating materials do not accumulate to impair the efficiency of the interceptor. The use of chemicals to dissolve grease is specifically prohibited. When an interceptor is cleaned, the accumulated sediment and floating material shall be removed and legally disposed of by means other than discharge to the sewer system. An interceptor is not considered to be properly maintained if for any reason it is not in good working condition or if the operational fluid capacity has been reduced by more than 25 percent by the accumulation of floating and settled solids, fats, oils and grease. The owner of any facility required to install an interceptor, the lessee and sublessee, if there be such, and any proprietor, operator or public works director of such facility are individually and severally liable for any failure of proper maintenance of such interceptor. If the interceptor is not properly maintained under the conditions of use, the public works director may require that the interceptor be resized and replaced.

(Ord. No. 1984, § 2(Exh. A), 3-10-26)

Ask a question about Fontana law

Corpus searches the Fontana sections it holds and shows the ones that match, with their citations. Free, no sign-in.